Comparison and Analysis of ISO/IEEE 11073, IHE PCD-01, and HL7 FHIR Messages for Personal Health Devices

OBJECTIVES: Increasing use of medical devices outside of healthcare facilities inevitably requires connectivity and interoperability between medical devices and healthcare information systems. To this end, standards have been developed and used to provide interoperability between personal health dev...

Descripción completa

Detalles Bibliográficos
Autores principales: Lee, Sungkee, Do, Hyoungho
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Korean Society of Medical Informatics 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5820086/
https://www.ncbi.nlm.nih.gov/pubmed/29503752
http://dx.doi.org/10.4258/hir.2018.24.1.46
_version_ 1783301313979744256
author Lee, Sungkee
Do, Hyoungho
author_facet Lee, Sungkee
Do, Hyoungho
author_sort Lee, Sungkee
collection PubMed
description OBJECTIVES: Increasing use of medical devices outside of healthcare facilities inevitably requires connectivity and interoperability between medical devices and healthcare information systems. To this end, standards have been developed and used to provide interoperability between personal health devices (PHDs) and external systems. ISO/IEEE 11073 standards and IHE PCD-01 standard messages have been used the most in the exchange of observation data of health devices. Recently, transmitting observation data using the HL7 FHIR standard has been devised in the name of DoF (Devices on FHIR) and adopted very fast. We compare and analyze these standards and suggest that which standard will work best at the different environments of device usage. METHODS: We generated each message/resource of the three standards for observed vital signs from blood pressure monitor and thermometer. Then, the size, the contents, and the exchange processes of these messages are compared and analyzed. RESULTS: ISO/IEEE 11073 standard message has the smallest data size, but it has no ability to contain the key information, patient information. On the other hand, PCD-01 messages and FHIR standards have the fields for patient information. HL7 DoF standards provide reusing of information unit known as resource, and it is relatively easy to parse DoF messages since it uses widely known XML and JSON. CONCLUSIONS: ISO/IEEE 11073 standards are suitable for devices having very small computing power. IHE PCD-01 and HL7 DoF messages can be used for the devices that need to be connected to hospital information systems that require patient information. When information reuse is frequent, DoF is advantageous over PCD-01.
format Online
Article
Text
id pubmed-5820086
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Korean Society of Medical Informatics
record_format MEDLINE/PubMed
spelling pubmed-58200862018-03-02 Comparison and Analysis of ISO/IEEE 11073, IHE PCD-01, and HL7 FHIR Messages for Personal Health Devices Lee, Sungkee Do, Hyoungho Healthc Inform Res Original Article OBJECTIVES: Increasing use of medical devices outside of healthcare facilities inevitably requires connectivity and interoperability between medical devices and healthcare information systems. To this end, standards have been developed and used to provide interoperability between personal health devices (PHDs) and external systems. ISO/IEEE 11073 standards and IHE PCD-01 standard messages have been used the most in the exchange of observation data of health devices. Recently, transmitting observation data using the HL7 FHIR standard has been devised in the name of DoF (Devices on FHIR) and adopted very fast. We compare and analyze these standards and suggest that which standard will work best at the different environments of device usage. METHODS: We generated each message/resource of the three standards for observed vital signs from blood pressure monitor and thermometer. Then, the size, the contents, and the exchange processes of these messages are compared and analyzed. RESULTS: ISO/IEEE 11073 standard message has the smallest data size, but it has no ability to contain the key information, patient information. On the other hand, PCD-01 messages and FHIR standards have the fields for patient information. HL7 DoF standards provide reusing of information unit known as resource, and it is relatively easy to parse DoF messages since it uses widely known XML and JSON. CONCLUSIONS: ISO/IEEE 11073 standards are suitable for devices having very small computing power. IHE PCD-01 and HL7 DoF messages can be used for the devices that need to be connected to hospital information systems that require patient information. When information reuse is frequent, DoF is advantageous over PCD-01. Korean Society of Medical Informatics 2018-01 2018-01-31 /pmc/articles/PMC5820086/ /pubmed/29503752 http://dx.doi.org/10.4258/hir.2018.24.1.46 Text en © 2018 The Korean Society of Medical Informatics http://creativecommons.org/licenses/by-nc/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Lee, Sungkee
Do, Hyoungho
Comparison and Analysis of ISO/IEEE 11073, IHE PCD-01, and HL7 FHIR Messages for Personal Health Devices
title Comparison and Analysis of ISO/IEEE 11073, IHE PCD-01, and HL7 FHIR Messages for Personal Health Devices
title_full Comparison and Analysis of ISO/IEEE 11073, IHE PCD-01, and HL7 FHIR Messages for Personal Health Devices
title_fullStr Comparison and Analysis of ISO/IEEE 11073, IHE PCD-01, and HL7 FHIR Messages for Personal Health Devices
title_full_unstemmed Comparison and Analysis of ISO/IEEE 11073, IHE PCD-01, and HL7 FHIR Messages for Personal Health Devices
title_short Comparison and Analysis of ISO/IEEE 11073, IHE PCD-01, and HL7 FHIR Messages for Personal Health Devices
title_sort comparison and analysis of iso/ieee 11073, ihe pcd-01, and hl7 fhir messages for personal health devices
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5820086/
https://www.ncbi.nlm.nih.gov/pubmed/29503752
http://dx.doi.org/10.4258/hir.2018.24.1.46
work_keys_str_mv AT leesungkee comparisonandanalysisofisoieee11073ihepcd01andhl7fhirmessagesforpersonalhealthdevices
AT dohyoungho comparisonandanalysisofisoieee11073ihepcd01andhl7fhirmessagesforpersonalhealthdevices