Cargando…

Revising Reverse-Phase Chromatographic Behavior for Efficient Differentiation of Both Positional and Geometrical Isomers of Dicaffeoylquinic Acids

Dicaffeoylquinic acids (diCQAs) are plant metabolites and undergo trans-cis-isomerization when exposed to UV irradiation. As such, diCQAs exist in both trans- and cis-configurations and amplify the already complex plant metabolome. However, analytical differentiation of these geometrical isomers usi...

Descripción completa

Detalles Bibliográficos
Autores principales: Masike, Keabetswe, Dubery, Ian, Steenkamp, Paul, Smit, Elize, Madala, Edwin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5821971/
https://www.ncbi.nlm.nih.gov/pubmed/29576885
http://dx.doi.org/10.1155/2018/8694579
_version_ 1783301599481823232
author Masike, Keabetswe
Dubery, Ian
Steenkamp, Paul
Smit, Elize
Madala, Edwin
author_facet Masike, Keabetswe
Dubery, Ian
Steenkamp, Paul
Smit, Elize
Madala, Edwin
author_sort Masike, Keabetswe
collection PubMed
description Dicaffeoylquinic acids (diCQAs) are plant metabolites and undergo trans-cis-isomerization when exposed to UV irradiation. As such, diCQAs exist in both trans- and cis-configurations and amplify the already complex plant metabolome. However, analytical differentiation of these geometrical isomers using mass spectrometry (MS) approaches has proven to be extremely challenging. Exploring the chromatographic space to develop possible conditions that would aid in differentially separating and determining the elution order of these isomers is therefore imperative. In this study, simple chromatographic parameters, such as column chemistry (phenyl versus alkyl), mobile phase composition (methanol or acetonitrile), and column temperature, were investigated to aid in the separation of diCQA geometrical isomers. The high-performance liquid chromatography photodiode array (HPLC-PDA) chromatograms revealed four isomers post UV irradiation of diCQA authentic standards. The elution profile/order was seen to vary on different reverse-phase column chemistries (phenyl versus alkyl) using different mobile phase composition. Here, the elution profile/order on the phenyl-derived column matrices (with methanol as the mobile phase composition) was observed to be relatively reproducible as compared to the alkyl (C(18)) columns. Chromatographic resolution of diCQA geometrical isomers can be enhanced with an increase in column temperature. Lastly, the study highlights that chromatographic elution order/profile cannot be relied upon to fathom the complexity of isomeric plant metabolites.
format Online
Article
Text
id pubmed-5821971
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-58219712018-03-25 Revising Reverse-Phase Chromatographic Behavior for Efficient Differentiation of Both Positional and Geometrical Isomers of Dicaffeoylquinic Acids Masike, Keabetswe Dubery, Ian Steenkamp, Paul Smit, Elize Madala, Edwin J Anal Methods Chem Research Article Dicaffeoylquinic acids (diCQAs) are plant metabolites and undergo trans-cis-isomerization when exposed to UV irradiation. As such, diCQAs exist in both trans- and cis-configurations and amplify the already complex plant metabolome. However, analytical differentiation of these geometrical isomers using mass spectrometry (MS) approaches has proven to be extremely challenging. Exploring the chromatographic space to develop possible conditions that would aid in differentially separating and determining the elution order of these isomers is therefore imperative. In this study, simple chromatographic parameters, such as column chemistry (phenyl versus alkyl), mobile phase composition (methanol or acetonitrile), and column temperature, were investigated to aid in the separation of diCQA geometrical isomers. The high-performance liquid chromatography photodiode array (HPLC-PDA) chromatograms revealed four isomers post UV irradiation of diCQA authentic standards. The elution profile/order was seen to vary on different reverse-phase column chemistries (phenyl versus alkyl) using different mobile phase composition. Here, the elution profile/order on the phenyl-derived column matrices (with methanol as the mobile phase composition) was observed to be relatively reproducible as compared to the alkyl (C(18)) columns. Chromatographic resolution of diCQA geometrical isomers can be enhanced with an increase in column temperature. Lastly, the study highlights that chromatographic elution order/profile cannot be relied upon to fathom the complexity of isomeric plant metabolites. Hindawi 2018-01-11 /pmc/articles/PMC5821971/ /pubmed/29576885 http://dx.doi.org/10.1155/2018/8694579 Text en Copyright © 2018 Keabetswe Masike et al. http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Masike, Keabetswe
Dubery, Ian
Steenkamp, Paul
Smit, Elize
Madala, Edwin
Revising Reverse-Phase Chromatographic Behavior for Efficient Differentiation of Both Positional and Geometrical Isomers of Dicaffeoylquinic Acids
title Revising Reverse-Phase Chromatographic Behavior for Efficient Differentiation of Both Positional and Geometrical Isomers of Dicaffeoylquinic Acids
title_full Revising Reverse-Phase Chromatographic Behavior for Efficient Differentiation of Both Positional and Geometrical Isomers of Dicaffeoylquinic Acids
title_fullStr Revising Reverse-Phase Chromatographic Behavior for Efficient Differentiation of Both Positional and Geometrical Isomers of Dicaffeoylquinic Acids
title_full_unstemmed Revising Reverse-Phase Chromatographic Behavior for Efficient Differentiation of Both Positional and Geometrical Isomers of Dicaffeoylquinic Acids
title_short Revising Reverse-Phase Chromatographic Behavior for Efficient Differentiation of Both Positional and Geometrical Isomers of Dicaffeoylquinic Acids
title_sort revising reverse-phase chromatographic behavior for efficient differentiation of both positional and geometrical isomers of dicaffeoylquinic acids
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5821971/
https://www.ncbi.nlm.nih.gov/pubmed/29576885
http://dx.doi.org/10.1155/2018/8694579
work_keys_str_mv AT masikekeabetswe revisingreversephasechromatographicbehaviorforefficientdifferentiationofbothpositionalandgeometricalisomersofdicaffeoylquinicacids
AT duberyian revisingreversephasechromatographicbehaviorforefficientdifferentiationofbothpositionalandgeometricalisomersofdicaffeoylquinicacids
AT steenkamppaul revisingreversephasechromatographicbehaviorforefficientdifferentiationofbothpositionalandgeometricalisomersofdicaffeoylquinicacids
AT smitelize revisingreversephasechromatographicbehaviorforefficientdifferentiationofbothpositionalandgeometricalisomersofdicaffeoylquinicacids
AT madalaedwin revisingreversephasechromatographicbehaviorforefficientdifferentiationofbothpositionalandgeometricalisomersofdicaffeoylquinicacids