Cargando…

Incisional Hernia Involving the Neobladder: Technical Considerations to Avoid Complications

The management of incisional hernia following radical cystectomy (RC) and neobladder diversion poses a special challenge. Mesh erosion into the neobladder is a potential complication of hernia repair in this setting. We describe our experience and steps to avoid this complication. Three patients dev...

Descripción completa

Detalles Bibliográficos
Autores principales: Katkoori, Devendar, Jayathillake, Anuradha, Eldefrawy, Ahmed, Manoharan, Murugesan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: TheScientificWorldJOURNAL 2009
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5823159/
https://www.ncbi.nlm.nih.gov/pubmed/19578707
http://dx.doi.org/10.1100/tsw.2009.84
_version_ 1783301827877404672
author Katkoori, Devendar
Jayathillake, Anuradha
Eldefrawy, Ahmed
Manoharan, Murugesan
author_facet Katkoori, Devendar
Jayathillake, Anuradha
Eldefrawy, Ahmed
Manoharan, Murugesan
author_sort Katkoori, Devendar
collection PubMed
description The management of incisional hernia following radical cystectomy (RC) and neobladder diversion poses a special challenge. Mesh erosion into the neobladder is a potential complication of hernia repair in this setting. We describe our experience and steps to avoid this complication. Three patients developed incisional hernias following RC involving the neobladder. The incisional hernias were repaired by the same surgeon. A systematic dissection and repair of the hernias with an onlay dual-layer mesh (made of polyglactin and polypropylene) was carried out. The critical steps were placing the polyglactin side of the mesh deeper and positioning of an omental flap anterior to the neobladder. The omental flap adds a protective layer that prevents adhesions between the neobladder and abdominal wall, and prevents erosion of the mesh into the fragile neobladder wall. All of these patients had received two cycles of neoadjuvant chemotherapy prior to RC. The time duration from RC to the repair of hernia was 7, 42, and 54 months. No intraoperative injury to the neobladder or other complication was noted during hernia repair. The patients were followed after hernia repair for 20, 22, and 42 months with no recurrence, mesh erosion, or other complications. Careful understanding and attention to details of the technique can minimize the risk of complications, especially incisional hernia recurrence, injury to the neobladder, and erosion of mesh into the neobladder wall.
format Online
Article
Text
id pubmed-5823159
institution National Center for Biotechnology Information
language English
publishDate 2009
publisher TheScientificWorldJOURNAL
record_format MEDLINE/PubMed
spelling pubmed-58231592018-03-14 Incisional Hernia Involving the Neobladder: Technical Considerations to Avoid Complications Katkoori, Devendar Jayathillake, Anuradha Eldefrawy, Ahmed Manoharan, Murugesan ScientificWorldJournal Technical Report The management of incisional hernia following radical cystectomy (RC) and neobladder diversion poses a special challenge. Mesh erosion into the neobladder is a potential complication of hernia repair in this setting. We describe our experience and steps to avoid this complication. Three patients developed incisional hernias following RC involving the neobladder. The incisional hernias were repaired by the same surgeon. A systematic dissection and repair of the hernias with an onlay dual-layer mesh (made of polyglactin and polypropylene) was carried out. The critical steps were placing the polyglactin side of the mesh deeper and positioning of an omental flap anterior to the neobladder. The omental flap adds a protective layer that prevents adhesions between the neobladder and abdominal wall, and prevents erosion of the mesh into the fragile neobladder wall. All of these patients had received two cycles of neoadjuvant chemotherapy prior to RC. The time duration from RC to the repair of hernia was 7, 42, and 54 months. No intraoperative injury to the neobladder or other complication was noted during hernia repair. The patients were followed after hernia repair for 20, 22, and 42 months with no recurrence, mesh erosion, or other complications. Careful understanding and attention to details of the technique can minimize the risk of complications, especially incisional hernia recurrence, injury to the neobladder, and erosion of mesh into the neobladder wall. TheScientificWorldJOURNAL 2009-06-30 /pmc/articles/PMC5823159/ /pubmed/19578707 http://dx.doi.org/10.1100/tsw.2009.84 Text en Copyright © 2009 Devendar Katkoori et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Technical Report
Katkoori, Devendar
Jayathillake, Anuradha
Eldefrawy, Ahmed
Manoharan, Murugesan
Incisional Hernia Involving the Neobladder: Technical Considerations to Avoid Complications
title Incisional Hernia Involving the Neobladder: Technical Considerations to Avoid Complications
title_full Incisional Hernia Involving the Neobladder: Technical Considerations to Avoid Complications
title_fullStr Incisional Hernia Involving the Neobladder: Technical Considerations to Avoid Complications
title_full_unstemmed Incisional Hernia Involving the Neobladder: Technical Considerations to Avoid Complications
title_short Incisional Hernia Involving the Neobladder: Technical Considerations to Avoid Complications
title_sort incisional hernia involving the neobladder: technical considerations to avoid complications
topic Technical Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5823159/
https://www.ncbi.nlm.nih.gov/pubmed/19578707
http://dx.doi.org/10.1100/tsw.2009.84
work_keys_str_mv AT katkooridevendar incisionalherniainvolvingtheneobladdertechnicalconsiderationstoavoidcomplications
AT jayathillakeanuradha incisionalherniainvolvingtheneobladdertechnicalconsiderationstoavoidcomplications
AT eldefrawyahmed incisionalherniainvolvingtheneobladdertechnicalconsiderationstoavoidcomplications
AT manoharanmurugesan incisionalherniainvolvingtheneobladdertechnicalconsiderationstoavoidcomplications