Cargando…
Fast Recognition of BCI-Inefficient Users Using Physiological Features from EEG Signals: A Screening Study of Stroke Patients
Motor imagery (MI) based brain-computer interface (BCI) has been developed as an alternative therapy for stroke rehabilitation. However, experimental evidence demonstrates that a significant portion (10–50%) of subjects are BCI-inefficient users (accuracy less than 70%). Thus, predicting BCI perform...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Frontiers Media S.A.
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5826359/ https://www.ncbi.nlm.nih.gov/pubmed/29515363 http://dx.doi.org/10.3389/fnins.2018.00093 |
_version_ | 1783302337509457920 |
---|---|
author | Shu, Xiaokang Chen, Shugeng Yao, Lin Sheng, Xinjun Zhang, Dingguo Jiang, Ning Jia, Jie Zhu, Xiangyang |
author_facet | Shu, Xiaokang Chen, Shugeng Yao, Lin Sheng, Xinjun Zhang, Dingguo Jiang, Ning Jia, Jie Zhu, Xiangyang |
author_sort | Shu, Xiaokang |
collection | PubMed |
description | Motor imagery (MI) based brain-computer interface (BCI) has been developed as an alternative therapy for stroke rehabilitation. However, experimental evidence demonstrates that a significant portion (10–50%) of subjects are BCI-inefficient users (accuracy less than 70%). Thus, predicting BCI performance prior to clinical BCI usage would facilitate the selection of suitable end-users and improve the efficiency of stroke rehabilitation. In the current study, we proposed two physiological variables, i.e., laterality index (LI) and cortical activation strength (CAS), to predict MI-BCI performance. Twenty-four stroke patients and 10 healthy subjects were recruited for this study. Each subject was required to perform two blocks of left- and right-hand MI tasks. Linear regression analyses were performed between the BCI accuracies and two physiological predictors. Here, the predictors were calculated from the electroencephalography (EEG) signals during paretic hand MI tasks (5 trials; approximately 1 min). LI values exhibited a statistically significant correlation with two-class BCI (left vs. right) performance (r = −0.732, p < 0.001), and CAS values exhibited a statistically significant correlation with brain-switch BCI (task vs. idle) performance (r = 0.641, p < 0.001). Furthermore, the BCI-inefficient users were successfully recognized with a sensitivity of 88.2% and a specificity of 85.7% in the two-class BCI. The brain-switch BCI achieved a sensitivity of 100.0% and a specificity of 87.5% in the discrimination of BCI-inefficient users. These results demonstrated that the proposed BCI predictors were promising to promote the BCI usage in stroke rehabilitation and contribute to a better understanding of the BCI-inefficiency phenomenon in stroke patients. |
format | Online Article Text |
id | pubmed-5826359 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Frontiers Media S.A. |
record_format | MEDLINE/PubMed |
spelling | pubmed-58263592018-03-07 Fast Recognition of BCI-Inefficient Users Using Physiological Features from EEG Signals: A Screening Study of Stroke Patients Shu, Xiaokang Chen, Shugeng Yao, Lin Sheng, Xinjun Zhang, Dingguo Jiang, Ning Jia, Jie Zhu, Xiangyang Front Neurosci Neuroscience Motor imagery (MI) based brain-computer interface (BCI) has been developed as an alternative therapy for stroke rehabilitation. However, experimental evidence demonstrates that a significant portion (10–50%) of subjects are BCI-inefficient users (accuracy less than 70%). Thus, predicting BCI performance prior to clinical BCI usage would facilitate the selection of suitable end-users and improve the efficiency of stroke rehabilitation. In the current study, we proposed two physiological variables, i.e., laterality index (LI) and cortical activation strength (CAS), to predict MI-BCI performance. Twenty-four stroke patients and 10 healthy subjects were recruited for this study. Each subject was required to perform two blocks of left- and right-hand MI tasks. Linear regression analyses were performed between the BCI accuracies and two physiological predictors. Here, the predictors were calculated from the electroencephalography (EEG) signals during paretic hand MI tasks (5 trials; approximately 1 min). LI values exhibited a statistically significant correlation with two-class BCI (left vs. right) performance (r = −0.732, p < 0.001), and CAS values exhibited a statistically significant correlation with brain-switch BCI (task vs. idle) performance (r = 0.641, p < 0.001). Furthermore, the BCI-inefficient users were successfully recognized with a sensitivity of 88.2% and a specificity of 85.7% in the two-class BCI. The brain-switch BCI achieved a sensitivity of 100.0% and a specificity of 87.5% in the discrimination of BCI-inefficient users. These results demonstrated that the proposed BCI predictors were promising to promote the BCI usage in stroke rehabilitation and contribute to a better understanding of the BCI-inefficiency phenomenon in stroke patients. Frontiers Media S.A. 2018-02-21 /pmc/articles/PMC5826359/ /pubmed/29515363 http://dx.doi.org/10.3389/fnins.2018.00093 Text en Copyright © 2018 Shu, Chen, Yao, Sheng, Zhang, Jiang, Jia and Zhu. http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms. |
spellingShingle | Neuroscience Shu, Xiaokang Chen, Shugeng Yao, Lin Sheng, Xinjun Zhang, Dingguo Jiang, Ning Jia, Jie Zhu, Xiangyang Fast Recognition of BCI-Inefficient Users Using Physiological Features from EEG Signals: A Screening Study of Stroke Patients |
title | Fast Recognition of BCI-Inefficient Users Using Physiological Features from EEG Signals: A Screening Study of Stroke Patients |
title_full | Fast Recognition of BCI-Inefficient Users Using Physiological Features from EEG Signals: A Screening Study of Stroke Patients |
title_fullStr | Fast Recognition of BCI-Inefficient Users Using Physiological Features from EEG Signals: A Screening Study of Stroke Patients |
title_full_unstemmed | Fast Recognition of BCI-Inefficient Users Using Physiological Features from EEG Signals: A Screening Study of Stroke Patients |
title_short | Fast Recognition of BCI-Inefficient Users Using Physiological Features from EEG Signals: A Screening Study of Stroke Patients |
title_sort | fast recognition of bci-inefficient users using physiological features from eeg signals: a screening study of stroke patients |
topic | Neuroscience |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5826359/ https://www.ncbi.nlm.nih.gov/pubmed/29515363 http://dx.doi.org/10.3389/fnins.2018.00093 |
work_keys_str_mv | AT shuxiaokang fastrecognitionofbciinefficientusersusingphysiologicalfeaturesfromeegsignalsascreeningstudyofstrokepatients AT chenshugeng fastrecognitionofbciinefficientusersusingphysiologicalfeaturesfromeegsignalsascreeningstudyofstrokepatients AT yaolin fastrecognitionofbciinefficientusersusingphysiologicalfeaturesfromeegsignalsascreeningstudyofstrokepatients AT shengxinjun fastrecognitionofbciinefficientusersusingphysiologicalfeaturesfromeegsignalsascreeningstudyofstrokepatients AT zhangdingguo fastrecognitionofbciinefficientusersusingphysiologicalfeaturesfromeegsignalsascreeningstudyofstrokepatients AT jiangning fastrecognitionofbciinefficientusersusingphysiologicalfeaturesfromeegsignalsascreeningstudyofstrokepatients AT jiajie fastrecognitionofbciinefficientusersusingphysiologicalfeaturesfromeegsignalsascreeningstudyofstrokepatients AT zhuxiangyang fastrecognitionofbciinefficientusersusingphysiologicalfeaturesfromeegsignalsascreeningstudyofstrokepatients |