Cargando…

Metal-ceramic bond strength between a feldspathic porcelain and a Co-Cr alloy fabricated with Direct Metal Laser Sintering technique

PURPOSE: The aim of the present study was to record the metal-ceramic bond strength of a feldspathic dental porcelain and a Co-Cr alloy, using the Direct Metal Laser Sintering technique (DMLS) for the fabrication of metal substrates. MATERIALS AND METHODS: Ten metal substrates were fabricated with p...

Descripción completa

Detalles Bibliográficos
Autores principales: Dimitriadis, Konstantinos, Spyropoulos, Konstantinos, Papadopoulos, Triantafillos
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Academy of Prosthodontics 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5829284/
https://www.ncbi.nlm.nih.gov/pubmed/29503711
http://dx.doi.org/10.4047/jap.2018.10.1.25
_version_ 1783302773346926592
author Dimitriadis, Konstantinos
Spyropoulos, Konstantinos
Papadopoulos, Triantafillos
author_facet Dimitriadis, Konstantinos
Spyropoulos, Konstantinos
Papadopoulos, Triantafillos
author_sort Dimitriadis, Konstantinos
collection PubMed
description PURPOSE: The aim of the present study was to record the metal-ceramic bond strength of a feldspathic dental porcelain and a Co-Cr alloy, using the Direct Metal Laser Sintering technique (DMLS) for the fabrication of metal substrates. MATERIALS AND METHODS: Ten metal substrates were fabricated with powder of a dental Co-Cr alloy using DMLS technique (test group) in dimensions according to ISO 9693. Another ten substrates were fabricated with a casing dental Co-Cr alloy using classic casting technique (control group) for comparison. Another three substrates were fabricated using each technique to record the Modulus of Elasticity (E) of the used alloys. All substrates were examined to record external and internal porosity. Feldspathic porcelain was applied on the substrates. Specimens were tested using the three-point bending test. The failure mode was determined using optical and scanning electron microscopy. The statistical analysis was performed using t-test. RESULTS: Substrates prepared using DMLS technique did not show internal porosity as compared to those produced using the casting technique. The E of control and test group was 222 ± 5.13 GPa and 227 ± 3 GPa, respectively. The bond strength was 51.87 ± 7.50 MPa for test group and 54.60 ± 6.20 MPa for control group. No statistically significant differences between the two groups were recorded. The mode of failure was mainly cohesive for all specimens. CONCLUSION: Specimens produced by the DMLS technique cover the lowest acceptable metal-ceramic bond strength of 25 MPa specified in ISO 9693 and present satisfactory bond strength for clinical use.
format Online
Article
Text
id pubmed-5829284
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher The Korean Academy of Prosthodontics
record_format MEDLINE/PubMed
spelling pubmed-58292842018-03-02 Metal-ceramic bond strength between a feldspathic porcelain and a Co-Cr alloy fabricated with Direct Metal Laser Sintering technique Dimitriadis, Konstantinos Spyropoulos, Konstantinos Papadopoulos, Triantafillos J Adv Prosthodont Original Article PURPOSE: The aim of the present study was to record the metal-ceramic bond strength of a feldspathic dental porcelain and a Co-Cr alloy, using the Direct Metal Laser Sintering technique (DMLS) for the fabrication of metal substrates. MATERIALS AND METHODS: Ten metal substrates were fabricated with powder of a dental Co-Cr alloy using DMLS technique (test group) in dimensions according to ISO 9693. Another ten substrates were fabricated with a casing dental Co-Cr alloy using classic casting technique (control group) for comparison. Another three substrates were fabricated using each technique to record the Modulus of Elasticity (E) of the used alloys. All substrates were examined to record external and internal porosity. Feldspathic porcelain was applied on the substrates. Specimens were tested using the three-point bending test. The failure mode was determined using optical and scanning electron microscopy. The statistical analysis was performed using t-test. RESULTS: Substrates prepared using DMLS technique did not show internal porosity as compared to those produced using the casting technique. The E of control and test group was 222 ± 5.13 GPa and 227 ± 3 GPa, respectively. The bond strength was 51.87 ± 7.50 MPa for test group and 54.60 ± 6.20 MPa for control group. No statistically significant differences between the two groups were recorded. The mode of failure was mainly cohesive for all specimens. CONCLUSION: Specimens produced by the DMLS technique cover the lowest acceptable metal-ceramic bond strength of 25 MPa specified in ISO 9693 and present satisfactory bond strength for clinical use. The Korean Academy of Prosthodontics 2018-02 2018-02-12 /pmc/articles/PMC5829284/ /pubmed/29503711 http://dx.doi.org/10.4047/jap.2018.10.1.25 Text en © 2018 The Korean Academy of Prosthodontics http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Dimitriadis, Konstantinos
Spyropoulos, Konstantinos
Papadopoulos, Triantafillos
Metal-ceramic bond strength between a feldspathic porcelain and a Co-Cr alloy fabricated with Direct Metal Laser Sintering technique
title Metal-ceramic bond strength between a feldspathic porcelain and a Co-Cr alloy fabricated with Direct Metal Laser Sintering technique
title_full Metal-ceramic bond strength between a feldspathic porcelain and a Co-Cr alloy fabricated with Direct Metal Laser Sintering technique
title_fullStr Metal-ceramic bond strength between a feldspathic porcelain and a Co-Cr alloy fabricated with Direct Metal Laser Sintering technique
title_full_unstemmed Metal-ceramic bond strength between a feldspathic porcelain and a Co-Cr alloy fabricated with Direct Metal Laser Sintering technique
title_short Metal-ceramic bond strength between a feldspathic porcelain and a Co-Cr alloy fabricated with Direct Metal Laser Sintering technique
title_sort metal-ceramic bond strength between a feldspathic porcelain and a co-cr alloy fabricated with direct metal laser sintering technique
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5829284/
https://www.ncbi.nlm.nih.gov/pubmed/29503711
http://dx.doi.org/10.4047/jap.2018.10.1.25
work_keys_str_mv AT dimitriadiskonstantinos metalceramicbondstrengthbetweenafeldspathicporcelainandacocralloyfabricatedwithdirectmetallasersinteringtechnique
AT spyropouloskonstantinos metalceramicbondstrengthbetweenafeldspathicporcelainandacocralloyfabricatedwithdirectmetallasersinteringtechnique
AT papadopoulostriantafillos metalceramicbondstrengthbetweenafeldspathicporcelainandacocralloyfabricatedwithdirectmetallasersinteringtechnique