Cargando…

Morphometric analysis of rat femoral vessels under a video magnification system

The right femoral vessels of 80 rats were identified and dissected. External lengths and diameters of femoral arteries and femoral veins were measured using either a microscope or a video magnification system. Findings were correlated to animals’ weights. Mean length was 14.33 mm for both femoral ar...

Descripción completa

Detalles Bibliográficos
Autores principales: de Barros, Rui Sergio Monteiro, Leal, Rafael Aquino, Teixeira, Renan Kleber Costa, Yamaki, Vitor Nagai, Costa, Felipe Lobato da Silva, Feijó, Daniel Haber, Valente, Andre Lopes
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Sociedade Brasileira de Angiologia e de Cirurgia Vascular (SBACV) 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5829698/
https://www.ncbi.nlm.nih.gov/pubmed/29930629
http://dx.doi.org/10.1590/1677-5449.011016
Descripción
Sumario:The right femoral vessels of 80 rats were identified and dissected. External lengths and diameters of femoral arteries and femoral veins were measured using either a microscope or a video magnification system. Findings were correlated to animals’ weights. Mean length was 14.33 mm for both femoral arteries and femoral veins, mean diameter of arteries was 0.65 mm and diameter of veins was 0.81 mm. In our sample, rats’ body weights were only correlated with the diameter of their femoral veins.