Multicenter experience from the UK and Ireland of use of lumen-apposing metal stent for transluminal drainage of pancreatic fluid collections

BACKGROUND AND STUDY AIMS:  Pancreatic fluid collection (PFC) is a common complication of pancreatitis for which endoscopic ultrasound-guided drainage is first-line treatment. A new single-device, lumen-apposing, covered self-expanding metal stent (LAMS) has been licensed for PFC drainage. We theref...

Descripción completa

Detalles Bibliográficos
Autores principales: Venkatachalapathy, Suresh Vasan, Bekkali, Noor, Pereira, Stephen, Johnson, Gavin, Oppong, Kofi, Nayar, Manu, Leeds, John, Paranandi, Bharat, Penman, Ian, Carroll, Nicholas, Godfrey, Edmund, James, Martin, Aithal, Guruprasad, McKay, Colin, Devlin, John, Wong, Terry, Makin, Alistair, Ryan, Barbara, Huggett, Matthew
Formato: Online Artículo Texto
Lenguaje:English
Publicado: © Georg Thieme Verlag KG 2018
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5829997/
https://www.ncbi.nlm.nih.gov/pubmed/29497684
http://dx.doi.org/10.1055/s-0043-125362
Descripción
Sumario:BACKGROUND AND STUDY AIMS:  Pancreatic fluid collection (PFC) is a common complication of pancreatitis for which endoscopic ultrasound-guided drainage is first-line treatment. A new single-device, lumen-apposing, covered self-expanding metal stent (LAMS) has been licensed for PFC drainage. We therefore present our multicenter experience with the LAMS for PFC drainage in a multicenter prospective case series to assess success and complication rates. PATIENTS AND METHODS:  All adult patients from 11 tertiary centers who had LAMS placement for PFC from July 2015 to July 2016 were included. Data including indications, technical success, clinical success, collection resolution, stent removal, early and late adverse events (AEs), mortality and recurrence at 6 months were collected. RESULTS:  116 patients, median age 52.5 years (range 16 – 80) and 67 % male, were treated with a single LAMS in each case. The indication was walled off necrosis (WON) in 70 and pseudocyst in 46. Median size of the PFC was 11 cm (5 – 21 cm) and the estimated median necrotic volume in WON was 30 % (5 % – 90 %). Stent insertion was technically successful in 115 (99.1 %) and clinically successful in 109 (94 %). Early serious AEs (SAEs): n = 7 sepsis, n = 1 stent blockage with food, n = 1 stent migration requiring laparotomy, n = 1 stent dislodgement and n = 1 bleeding requiring emboliZation. Late AEs: n = 1 buried stent and n = 1 esophageal fistula. Non-procedure-related deaths: n = 3 (2.5 %). CONCLUSION:  This multicenter case series demonstrates that use of the new LAMS is feasible, effective and relatively safe in draining PFC with a technical success rate of 99 % and cumulative SAE rate of 11.2 %.