Cargando…

Variability of non-Gaussian diffusion MRI and intravoxel incoherent motion (IVIM) measurements in the breast

We prospectively examined the variability of non-Gaussian diffusion magnetic resonance imaging (MRI) and intravoxel incoherent motion (IVIM) measurements with different numbers of b-values and excitations in normal breast tissue and breast lesions. Thirteen volunteers and fourteen patients with brea...

Descripción completa

Detalles Bibliográficos
Autores principales: Iima, Mami, Kataoka, Masako, Kanao, Shotaro, Kawai, Makiko, Onishi, Natsuko, Koyasu, Sho, Murata, Katsutoshi, Ohashi, Akane, Sakaguchi, Rena, Togashi, Kaori
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5832256/
https://www.ncbi.nlm.nih.gov/pubmed/29494639
http://dx.doi.org/10.1371/journal.pone.0193444
_version_ 1783303297260584960
author Iima, Mami
Kataoka, Masako
Kanao, Shotaro
Kawai, Makiko
Onishi, Natsuko
Koyasu, Sho
Murata, Katsutoshi
Ohashi, Akane
Sakaguchi, Rena
Togashi, Kaori
author_facet Iima, Mami
Kataoka, Masako
Kanao, Shotaro
Kawai, Makiko
Onishi, Natsuko
Koyasu, Sho
Murata, Katsutoshi
Ohashi, Akane
Sakaguchi, Rena
Togashi, Kaori
author_sort Iima, Mami
collection PubMed
description We prospectively examined the variability of non-Gaussian diffusion magnetic resonance imaging (MRI) and intravoxel incoherent motion (IVIM) measurements with different numbers of b-values and excitations in normal breast tissue and breast lesions. Thirteen volunteers and fourteen patients with breast lesions (seven malignant, eight benign; one patient had bilateral lesions) were recruited in this prospective study (approved by the Internal Review Board). Diffusion-weighted MRI was performed with 16 b-values (0–2500 s/mm(2) with one number of excitations [NEX]) and five b-values (0–2500 s/mm(2), 3 NEX), using a 3T breast MRI. Intravoxel incoherent motion (flowing blood volume fraction [fIVIM] and pseudodiffusion coefficient [D*]) and non-Gaussian diffusion (theoretical apparent diffusion coefficient [ADC] at b value of 0 sec/mm(2) [ADC(0)] and kurtosis [K]) parameters were estimated from IVIM and Kurtosis models using 16 b-values, and synthetic apparent diffusion coefficient (sADC) values were obtained from two key b-values. The variabilities between and within subjects and between different diffusion acquisition methods were estimated. There were no statistical differences in ADC(0), K, or sADC values between the different b-values or NEX. A good agreement of diffusion parameters was observed between 16 b-values (one NEX), five b-values (one NEX), and five b-values (three NEX) in normal breast tissue or breast lesions. Insufficient agreement was observed for IVIM parameters. There were no statistical differences in the non-Gaussian diffusion MRI estimated values obtained from a different number of b-values or excitations in normal breast tissue or breast lesions. These data suggest that a limited MRI protocol using a few b-values might be relevant in a clinical setting for the estimation of non-Gaussian diffusion MRI parameters in normal breast tissue and breast lesions.
format Online
Article
Text
id pubmed-5832256
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-58322562018-03-23 Variability of non-Gaussian diffusion MRI and intravoxel incoherent motion (IVIM) measurements in the breast Iima, Mami Kataoka, Masako Kanao, Shotaro Kawai, Makiko Onishi, Natsuko Koyasu, Sho Murata, Katsutoshi Ohashi, Akane Sakaguchi, Rena Togashi, Kaori PLoS One Research Article We prospectively examined the variability of non-Gaussian diffusion magnetic resonance imaging (MRI) and intravoxel incoherent motion (IVIM) measurements with different numbers of b-values and excitations in normal breast tissue and breast lesions. Thirteen volunteers and fourteen patients with breast lesions (seven malignant, eight benign; one patient had bilateral lesions) were recruited in this prospective study (approved by the Internal Review Board). Diffusion-weighted MRI was performed with 16 b-values (0–2500 s/mm(2) with one number of excitations [NEX]) and five b-values (0–2500 s/mm(2), 3 NEX), using a 3T breast MRI. Intravoxel incoherent motion (flowing blood volume fraction [fIVIM] and pseudodiffusion coefficient [D*]) and non-Gaussian diffusion (theoretical apparent diffusion coefficient [ADC] at b value of 0 sec/mm(2) [ADC(0)] and kurtosis [K]) parameters were estimated from IVIM and Kurtosis models using 16 b-values, and synthetic apparent diffusion coefficient (sADC) values were obtained from two key b-values. The variabilities between and within subjects and between different diffusion acquisition methods were estimated. There were no statistical differences in ADC(0), K, or sADC values between the different b-values or NEX. A good agreement of diffusion parameters was observed between 16 b-values (one NEX), five b-values (one NEX), and five b-values (three NEX) in normal breast tissue or breast lesions. Insufficient agreement was observed for IVIM parameters. There were no statistical differences in the non-Gaussian diffusion MRI estimated values obtained from a different number of b-values or excitations in normal breast tissue or breast lesions. These data suggest that a limited MRI protocol using a few b-values might be relevant in a clinical setting for the estimation of non-Gaussian diffusion MRI parameters in normal breast tissue and breast lesions. Public Library of Science 2018-03-01 /pmc/articles/PMC5832256/ /pubmed/29494639 http://dx.doi.org/10.1371/journal.pone.0193444 Text en © 2018 Iima et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Iima, Mami
Kataoka, Masako
Kanao, Shotaro
Kawai, Makiko
Onishi, Natsuko
Koyasu, Sho
Murata, Katsutoshi
Ohashi, Akane
Sakaguchi, Rena
Togashi, Kaori
Variability of non-Gaussian diffusion MRI and intravoxel incoherent motion (IVIM) measurements in the breast
title Variability of non-Gaussian diffusion MRI and intravoxel incoherent motion (IVIM) measurements in the breast
title_full Variability of non-Gaussian diffusion MRI and intravoxel incoherent motion (IVIM) measurements in the breast
title_fullStr Variability of non-Gaussian diffusion MRI and intravoxel incoherent motion (IVIM) measurements in the breast
title_full_unstemmed Variability of non-Gaussian diffusion MRI and intravoxel incoherent motion (IVIM) measurements in the breast
title_short Variability of non-Gaussian diffusion MRI and intravoxel incoherent motion (IVIM) measurements in the breast
title_sort variability of non-gaussian diffusion mri and intravoxel incoherent motion (ivim) measurements in the breast
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5832256/
https://www.ncbi.nlm.nih.gov/pubmed/29494639
http://dx.doi.org/10.1371/journal.pone.0193444
work_keys_str_mv AT iimamami variabilityofnongaussiandiffusionmriandintravoxelincoherentmotionivimmeasurementsinthebreast
AT kataokamasako variabilityofnongaussiandiffusionmriandintravoxelincoherentmotionivimmeasurementsinthebreast
AT kanaoshotaro variabilityofnongaussiandiffusionmriandintravoxelincoherentmotionivimmeasurementsinthebreast
AT kawaimakiko variabilityofnongaussiandiffusionmriandintravoxelincoherentmotionivimmeasurementsinthebreast
AT onishinatsuko variabilityofnongaussiandiffusionmriandintravoxelincoherentmotionivimmeasurementsinthebreast
AT koyasusho variabilityofnongaussiandiffusionmriandintravoxelincoherentmotionivimmeasurementsinthebreast
AT muratakatsutoshi variabilityofnongaussiandiffusionmriandintravoxelincoherentmotionivimmeasurementsinthebreast
AT ohashiakane variabilityofnongaussiandiffusionmriandintravoxelincoherentmotionivimmeasurementsinthebreast
AT sakaguchirena variabilityofnongaussiandiffusionmriandintravoxelincoherentmotionivimmeasurementsinthebreast
AT togashikaori variabilityofnongaussiandiffusionmriandintravoxelincoherentmotionivimmeasurementsinthebreast