Inappropriate shocks in single-chamber and subcutaneous implantable cardioverter-defibrillators: a systematic review and meta-analysis

AIMS: Single-chamber (VR-ICD) and subcutaneous (S-ICD) implantable cardioverter-defibrillators are effective to protect patients against sudden death but expose them to higher risk of inappropriate shock (IS). We sought to quantify the annual rate and influencing factors of ISs in VR- and S-ICDs fro...

Descripción completa

Detalles Bibliográficos
Autores principales: Auricchio, Angelo, Hudnall, J Harrison, Schloss, Edward J, Sterns, Laurence D, Kurita, Takashi, Meijer, Albert, Fagan, Dedra H, Rogers, Tyson
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Oxford University Press 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5834016/
https://www.ncbi.nlm.nih.gov/pubmed/28340005
http://dx.doi.org/10.1093/europace/euw415
_version_ 1783303580985327616
author Auricchio, Angelo
Hudnall, J Harrison
Schloss, Edward J
Sterns, Laurence D
Kurita, Takashi
Meijer, Albert
Fagan, Dedra H
Rogers, Tyson
author_facet Auricchio, Angelo
Hudnall, J Harrison
Schloss, Edward J
Sterns, Laurence D
Kurita, Takashi
Meijer, Albert
Fagan, Dedra H
Rogers, Tyson
author_sort Auricchio, Angelo
collection PubMed
description AIMS: Single-chamber (VR-ICD) and subcutaneous (S-ICD) implantable cardioverter-defibrillators are effective to protect patients against sudden death but expose them to higher risk of inappropriate shock (IS). We sought to quantify the annual rate and influencing factors of ISs in VR- and S-ICDs from the literature. METHODS AND RESULTS: PubMed, Embase, and Cochrane Library were searched for full text articles with IS rates. Poisson distribution estimated proportion of patients with ISs; rates were annualized based on follow-up duration. Random effects meta-analysis accounted for study-to-study variation. Out of 3264 articles, 16 qualified for the meta-analysis. Across studies, 6.4% [95% confidence interval (CI) 5.1–7.9%] of patients received an IS per year. Meta-regression analyses demonstrated that IS rates were lower in more recent studies [rate ratio (RR) per year: 0.93, 95% CI: 0.87–0.98; P = 0.01] and trended lower in studies with longer follow-up (RR per year: 0.78, 95% CI: 0.60–1.01; P = 0.06). Use of S-ICDs (RR: 1.81, 95% CI: 0.86–3.81; P = 0.12) and ventricular tachycardia zone programmed on (RR: 1.13, 95% CI: 0.65–1.97; P = 0.66) were not associated with a significantly increased change in risk. The IS rate observed in one of the more recent studies was significantly lower than predicted after accounting for covariates (RR: 0.29, 95% CI: 0.14–0.60; P < 0.001). CONCLUSIONS: A comprehensive review of the literature shows that 6.4% of patients with ICDs experienced their first IS annually. One of the 16 studies was better than predicted with the lowest reported rate (1.9%) and could not be explained by timing of the study or other covariates.
format Online
Article
Text
id pubmed-5834016
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Oxford University Press
record_format MEDLINE/PubMed
spelling pubmed-58340162018-03-07 Inappropriate shocks in single-chamber and subcutaneous implantable cardioverter-defibrillators: a systematic review and meta-analysis Auricchio, Angelo Hudnall, J Harrison Schloss, Edward J Sterns, Laurence D Kurita, Takashi Meijer, Albert Fagan, Dedra H Rogers, Tyson Europace Clinical Research AIMS: Single-chamber (VR-ICD) and subcutaneous (S-ICD) implantable cardioverter-defibrillators are effective to protect patients against sudden death but expose them to higher risk of inappropriate shock (IS). We sought to quantify the annual rate and influencing factors of ISs in VR- and S-ICDs from the literature. METHODS AND RESULTS: PubMed, Embase, and Cochrane Library were searched for full text articles with IS rates. Poisson distribution estimated proportion of patients with ISs; rates were annualized based on follow-up duration. Random effects meta-analysis accounted for study-to-study variation. Out of 3264 articles, 16 qualified for the meta-analysis. Across studies, 6.4% [95% confidence interval (CI) 5.1–7.9%] of patients received an IS per year. Meta-regression analyses demonstrated that IS rates were lower in more recent studies [rate ratio (RR) per year: 0.93, 95% CI: 0.87–0.98; P = 0.01] and trended lower in studies with longer follow-up (RR per year: 0.78, 95% CI: 0.60–1.01; P = 0.06). Use of S-ICDs (RR: 1.81, 95% CI: 0.86–3.81; P = 0.12) and ventricular tachycardia zone programmed on (RR: 1.13, 95% CI: 0.65–1.97; P = 0.66) were not associated with a significantly increased change in risk. The IS rate observed in one of the more recent studies was significantly lower than predicted after accounting for covariates (RR: 0.29, 95% CI: 0.14–0.60; P < 0.001). CONCLUSIONS: A comprehensive review of the literature shows that 6.4% of patients with ICDs experienced their first IS annually. One of the 16 studies was better than predicted with the lowest reported rate (1.9%) and could not be explained by timing of the study or other covariates. Oxford University Press 2017-12 2017-03-10 /pmc/articles/PMC5834016/ /pubmed/28340005 http://dx.doi.org/10.1093/europace/euw415 Text en © The Author 2017. Published by Oxford University Press on behalf of the European Society of Cardiology http://creativecommons.org/licenses/by-nc/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/), which permits non-commercial re-use, distribution, and reproduction in any medium, provided the original work is properly cited. For commercial re-use, please contact journals.permissions@oup.com
spellingShingle Clinical Research
Auricchio, Angelo
Hudnall, J Harrison
Schloss, Edward J
Sterns, Laurence D
Kurita, Takashi
Meijer, Albert
Fagan, Dedra H
Rogers, Tyson
Inappropriate shocks in single-chamber and subcutaneous implantable cardioverter-defibrillators: a systematic review and meta-analysis
title Inappropriate shocks in single-chamber and subcutaneous implantable cardioverter-defibrillators: a systematic review and meta-analysis
title_full Inappropriate shocks in single-chamber and subcutaneous implantable cardioverter-defibrillators: a systematic review and meta-analysis
title_fullStr Inappropriate shocks in single-chamber and subcutaneous implantable cardioverter-defibrillators: a systematic review and meta-analysis
title_full_unstemmed Inappropriate shocks in single-chamber and subcutaneous implantable cardioverter-defibrillators: a systematic review and meta-analysis
title_short Inappropriate shocks in single-chamber and subcutaneous implantable cardioverter-defibrillators: a systematic review and meta-analysis
title_sort inappropriate shocks in single-chamber and subcutaneous implantable cardioverter-defibrillators: a systematic review and meta-analysis
topic Clinical Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5834016/
https://www.ncbi.nlm.nih.gov/pubmed/28340005
http://dx.doi.org/10.1093/europace/euw415
work_keys_str_mv AT auricchioangelo inappropriateshocksinsinglechamberandsubcutaneousimplantablecardioverterdefibrillatorsasystematicreviewandmetaanalysis
AT hudnalljharrison inappropriateshocksinsinglechamberandsubcutaneousimplantablecardioverterdefibrillatorsasystematicreviewandmetaanalysis
AT schlossedwardj inappropriateshocksinsinglechamberandsubcutaneousimplantablecardioverterdefibrillatorsasystematicreviewandmetaanalysis
AT sternslaurenced inappropriateshocksinsinglechamberandsubcutaneousimplantablecardioverterdefibrillatorsasystematicreviewandmetaanalysis
AT kuritatakashi inappropriateshocksinsinglechamberandsubcutaneousimplantablecardioverterdefibrillatorsasystematicreviewandmetaanalysis
AT meijeralbert inappropriateshocksinsinglechamberandsubcutaneousimplantablecardioverterdefibrillatorsasystematicreviewandmetaanalysis
AT fagandedrah inappropriateshocksinsinglechamberandsubcutaneousimplantablecardioverterdefibrillatorsasystematicreviewandmetaanalysis
AT rogerstyson inappropriateshocksinsinglechamberandsubcutaneousimplantablecardioverterdefibrillatorsasystematicreviewandmetaanalysis