The aim of this study was to evaluate and compare the diagnostic accuracy, the inter-rater agreement and raters’ certainty of cone beam computed tomography (CBCT) and radiography for the detection of scaphoid fractures. Our hypothesis is that the CBCT has a higher diagnostic accuracy for scaphoid fr...

Descripción completa

Detalles Bibliográficos
Autores principales: Neubauer, Jakob, Benndorf, Matthias, Ehritt-Braun, Claudia, Reising, Kilian, Yilmaz, Tayfun, Klein, Christopher, Zajonc, Horst, Kotter, Elmar, Langer, Mathias, Goerke, Sebastian Moritz
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group UK 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5834639/
https://www.ncbi.nlm.nih.gov/pubmed/29500380
http://dx.doi.org/10.1038/s41598-018-22331-8
_version_ 1783303689630384128
author Neubauer, Jakob
Benndorf, Matthias
Ehritt-Braun, Claudia
Reising, Kilian
Yilmaz, Tayfun
Klein, Christopher
Zajonc, Horst
Kotter, Elmar
Langer, Mathias
Goerke, Sebastian Moritz
author_facet Neubauer, Jakob
Benndorf, Matthias
Ehritt-Braun, Claudia
Reising, Kilian
Yilmaz, Tayfun
Klein, Christopher
Zajonc, Horst
Kotter, Elmar
Langer, Mathias
Goerke, Sebastian Moritz
author_sort Neubauer, Jakob
collection PubMed
description The aim of this study was to evaluate and compare the diagnostic accuracy, the inter-rater agreement and raters’ certainty of cone beam computed tomography (CBCT) and radiography for the detection of scaphoid fractures. Our hypothesis is that the CBCT has a higher diagnostic accuracy for scaphoid fractures than radiography. We retrospectively analysed patients who underwent both radiography and CBCT examinations within 4 days to rule out a scaphoid fracture over a 2-year period in our institution. 4 blinded radiologists and orthopaedic surgeons independently rated the images regarding the presence of a scaphoid fracture. The reference standard was evaluated by two radiologists in a consensus reading. Inter-rater correlation was evaluated, pooled sensitivity, specificity, positive and negative predictive values were calculated and compared. 102 patients met the inclusion criteria. 52% of them had a scaphoid fracture. The inter-rater correlation was higher in the CBCT compared to radiography (P < 0.001). Sensitivity, specificity, positive and negative predictive values were higher for CBCT than for radiography (P < 0.019). Observers’ fracture classifications showed a higher correlation with the reference standard in the CBCT. Observers’ certainty for fracture detection and classification were higher in the CBCT. CBCT shows a higher diagnostic accuracy for scaphoid fractures than radiography.
format Online
Article
Text
id pubmed-5834639
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Nature Publishing Group UK
record_format MEDLINE/PubMed
spelling pubmed-58346392018-03-05 Comparison of the diagnostic accuracy of cone beam computed tomography and radiography for scaphoid fractures Neubauer, Jakob Benndorf, Matthias Ehritt-Braun, Claudia Reising, Kilian Yilmaz, Tayfun Klein, Christopher Zajonc, Horst Kotter, Elmar Langer, Mathias Goerke, Sebastian Moritz Sci Rep Article The aim of this study was to evaluate and compare the diagnostic accuracy, the inter-rater agreement and raters’ certainty of cone beam computed tomography (CBCT) and radiography for the detection of scaphoid fractures. Our hypothesis is that the CBCT has a higher diagnostic accuracy for scaphoid fractures than radiography. We retrospectively analysed patients who underwent both radiography and CBCT examinations within 4 days to rule out a scaphoid fracture over a 2-year period in our institution. 4 blinded radiologists and orthopaedic surgeons independently rated the images regarding the presence of a scaphoid fracture. The reference standard was evaluated by two radiologists in a consensus reading. Inter-rater correlation was evaluated, pooled sensitivity, specificity, positive and negative predictive values were calculated and compared. 102 patients met the inclusion criteria. 52% of them had a scaphoid fracture. The inter-rater correlation was higher in the CBCT compared to radiography (P < 0.001). Sensitivity, specificity, positive and negative predictive values were higher for CBCT than for radiography (P < 0.019). Observers’ fracture classifications showed a higher correlation with the reference standard in the CBCT. Observers’ certainty for fracture detection and classification were higher in the CBCT. CBCT shows a higher diagnostic accuracy for scaphoid fractures than radiography. Nature Publishing Group UK 2018-03-02 /pmc/articles/PMC5834639/ /pubmed/29500380 http://dx.doi.org/10.1038/s41598-018-22331-8 Text en © The Author(s) 2018 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/.
spellingShingle Article
Neubauer, Jakob
Benndorf, Matthias
Ehritt-Braun, Claudia
Reising, Kilian
Yilmaz, Tayfun
Klein, Christopher
Zajonc, Horst
Kotter, Elmar
Langer, Mathias
Goerke, Sebastian Moritz
Comparison of the diagnostic accuracy of cone beam computed tomography and radiography for scaphoid fractures
title Comparison of the diagnostic accuracy of cone beam computed tomography and radiography for scaphoid fractures
title_full Comparison of the diagnostic accuracy of cone beam computed tomography and radiography for scaphoid fractures
title_fullStr Comparison of the diagnostic accuracy of cone beam computed tomography and radiography for scaphoid fractures
title_full_unstemmed Comparison of the diagnostic accuracy of cone beam computed tomography and radiography for scaphoid fractures
title_short Comparison of the diagnostic accuracy of cone beam computed tomography and radiography for scaphoid fractures
title_sort comparison of the diagnostic accuracy of cone beam computed tomography and radiography for scaphoid fractures
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5834639/
https://www.ncbi.nlm.nih.gov/pubmed/29500380
http://dx.doi.org/10.1038/s41598-018-22331-8
work_keys_str_mv AT neubauerjakob comparisonofthediagnosticaccuracyofconebeamcomputedtomographyandradiographyforscaphoidfractures
AT benndorfmatthias comparisonofthediagnosticaccuracyofconebeamcomputedtomographyandradiographyforscaphoidfractures
AT ehrittbraunclaudia comparisonofthediagnosticaccuracyofconebeamcomputedtomographyandradiographyforscaphoidfractures
AT reisingkilian comparisonofthediagnosticaccuracyofconebeamcomputedtomographyandradiographyforscaphoidfractures
AT yilmaztayfun comparisonofthediagnosticaccuracyofconebeamcomputedtomographyandradiographyforscaphoidfractures
AT kleinchristopher comparisonofthediagnosticaccuracyofconebeamcomputedtomographyandradiographyforscaphoidfractures
AT zajonchorst comparisonofthediagnosticaccuracyofconebeamcomputedtomographyandradiographyforscaphoidfractures
AT kotterelmar comparisonofthediagnosticaccuracyofconebeamcomputedtomographyandradiographyforscaphoidfractures
AT langermathias comparisonofthediagnosticaccuracyofconebeamcomputedtomographyandradiographyforscaphoidfractures
AT goerkesebastianmoritz comparisonofthediagnosticaccuracyofconebeamcomputedtomographyandradiographyforscaphoidfractures