Jetstream XC Device for Treatment of Long Viabahn Stents Occlusions in the Superficial Femoral Artery: A Report of Two Cases

Repeated restenotic events are common in superficial femoral artery and as of late, Viabahn stent grafts have been FDA (U.S. Food & Drug Administration) approved. Viabahn have been particularly attractive given that they provided a physical barrier for the development of neointimal hyperplasia....

Descripción completa

Detalles Bibliográficos
Autores principales: Kim, Tae-Hoon, Chavarria, Nelson, Dahal, Khagendra, Azrin, Michael, Lee, Juyong
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Japanese College of Angiology / The Japanese Society for Vascular Surgery / Japanese Society of Phlebology 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5835424/
https://www.ncbi.nlm.nih.gov/pubmed/29515712
http://dx.doi.org/10.3400/avd.cr.17-00028
_version_ 1783303809354694656
author Kim, Tae-Hoon
Chavarria, Nelson
Dahal, Khagendra
Azrin, Michael
Lee, Juyong
author_facet Kim, Tae-Hoon
Chavarria, Nelson
Dahal, Khagendra
Azrin, Michael
Lee, Juyong
author_sort Kim, Tae-Hoon
collection PubMed
description Repeated restenotic events are common in superficial femoral artery and as of late, Viabahn stent grafts have been FDA (U.S. Food & Drug Administration) approved. Viabahn have been particularly attractive given that they provided a physical barrier for the development of neointimal hyperplasia. This particular feature however, also underscores one of the main limitations of the therapy; providing a physical barrier of collateral circulation and predisposing to acute limb ischemia. Viabahn endograft thrombosis is characterized by stent edge stenosis and endograft thrombosis. Here we present 2 cases of Viabahn graft thrombosis successfully treated with the Jetstream atherectomy device, a rotational cutter with aspiration capacity.
format Online
Article
Text
id pubmed-5835424
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Japanese College of Angiology / The Japanese Society for Vascular Surgery / Japanese Society of Phlebology
record_format MEDLINE/PubMed
spelling pubmed-58354242018-03-07 Jetstream XC Device for Treatment of Long Viabahn Stents Occlusions in the Superficial Femoral Artery: A Report of Two Cases Kim, Tae-Hoon Chavarria, Nelson Dahal, Khagendra Azrin, Michael Lee, Juyong Ann Vasc Dis Case Report Repeated restenotic events are common in superficial femoral artery and as of late, Viabahn stent grafts have been FDA (U.S. Food & Drug Administration) approved. Viabahn have been particularly attractive given that they provided a physical barrier for the development of neointimal hyperplasia. This particular feature however, also underscores one of the main limitations of the therapy; providing a physical barrier of collateral circulation and predisposing to acute limb ischemia. Viabahn endograft thrombosis is characterized by stent edge stenosis and endograft thrombosis. Here we present 2 cases of Viabahn graft thrombosis successfully treated with the Jetstream atherectomy device, a rotational cutter with aspiration capacity. Japanese College of Angiology / The Japanese Society for Vascular Surgery / Japanese Society of Phlebology 2017-12-25 /pmc/articles/PMC5835424/ /pubmed/29515712 http://dx.doi.org/10.3400/avd.cr.17-00028 Text en Copyright © 2017 Annals of Vascular Diseases http://creativecommons.org/licenses/by-nc-sa/4.0/ This article is distributed under the terms of the Creative Commons Attribution License, which permits use, distribution, and reproduction in any medium, provided the credit of the original work, a link to the license, and indication of any change are properly given, and the original work is not used for commercial purposes. Remixed or transformed contributions must be distributed under the same license as the original.
spellingShingle Case Report
Kim, Tae-Hoon
Chavarria, Nelson
Dahal, Khagendra
Azrin, Michael
Lee, Juyong
Jetstream XC Device for Treatment of Long Viabahn Stents Occlusions in the Superficial Femoral Artery: A Report of Two Cases
title Jetstream XC Device for Treatment of Long Viabahn Stents Occlusions in the Superficial Femoral Artery: A Report of Two Cases
title_full Jetstream XC Device for Treatment of Long Viabahn Stents Occlusions in the Superficial Femoral Artery: A Report of Two Cases
title_fullStr Jetstream XC Device for Treatment of Long Viabahn Stents Occlusions in the Superficial Femoral Artery: A Report of Two Cases
title_full_unstemmed Jetstream XC Device for Treatment of Long Viabahn Stents Occlusions in the Superficial Femoral Artery: A Report of Two Cases
title_short Jetstream XC Device for Treatment of Long Viabahn Stents Occlusions in the Superficial Femoral Artery: A Report of Two Cases
title_sort jetstream xc device for treatment of long viabahn stents occlusions in the superficial femoral artery: a report of two cases
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5835424/
https://www.ncbi.nlm.nih.gov/pubmed/29515712
http://dx.doi.org/10.3400/avd.cr.17-00028
work_keys_str_mv AT kimtaehoon jetstreamxcdevicefortreatmentoflongviabahnstentsocclusionsinthesuperficialfemoralarteryareportoftwocases
AT chavarrianelson jetstreamxcdevicefortreatmentoflongviabahnstentsocclusionsinthesuperficialfemoralarteryareportoftwocases
AT dahalkhagendra jetstreamxcdevicefortreatmentoflongviabahnstentsocclusionsinthesuperficialfemoralarteryareportoftwocases
AT azrinmichael jetstreamxcdevicefortreatmentoflongviabahnstentsocclusionsinthesuperficialfemoralarteryareportoftwocases
AT leejuyong jetstreamxcdevicefortreatmentoflongviabahnstentsocclusionsinthesuperficialfemoralarteryareportoftwocases