Cargando…

Thermafil: A New Clinical Approach Due to New Dimensional Evaluations

BACKGROUND: There are a lot of techniques to obturate the root canals, but lateral condensation of gutta-percha is the most used one. An important aspect of thermafil is the error margin tolerated by the manufacturer in the production of plastic carriers. In literature, there is no evidence about di...

Descripción completa

Detalles Bibliográficos
Autores principales: Vittoria, G., Pantaleo, G., Blasi, A., Spagnuolo, G., Iandolo, A., Amato, M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Bentham Open 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5838644/
https://www.ncbi.nlm.nih.gov/pubmed/29541263
http://dx.doi.org/10.2174/1874210601812010173
_version_ 1783304291646177280
author Vittoria, G.
Pantaleo, G.
Blasi, A.
Spagnuolo, G.
Iandolo, A.
Amato, M.
author_facet Vittoria, G.
Pantaleo, G.
Blasi, A.
Spagnuolo, G.
Iandolo, A.
Amato, M.
author_sort Vittoria, G.
collection PubMed
description BACKGROUND: There are a lot of techniques to obturate the root canals, but lateral condensation of gutta-percha is the most used one. An important aspect of thermafil is the error margin tolerated by the manufacturer in the production of plastic carriers. In literature, there is no evidence about discrepancy percentage between different carriers. It is demonstrated that the error margin of gutta-percha is 0.5% and is 0.2% for metal files (ISO standards). OBJECTIVE: The aim of this study was to evaluate the real dimensions of thermafil plastic carriers observed by the stereo microscope measuring the dimensional discrepancy between them. METHODS: For this study, 80 new thermafil (Dentsply Maillefer) have been selected. 40 thermafil 0.25 and 40 thermafil 0.30. Through 60X stereo microscope, the dimensions of the plastic carrier tips have been measured. The dimensions of the plastic carrier were also measured after a heating cycle. ZL GAL 11TUSM (Zetaline stereo evolution) microscope was used to observe the samples. Measurements were made through a dedicated software (Image Focus). All samples were analysed at 60X. RESULTS: A non-parametric paired test (Wilcoxon test) was used to compare baseline and after heating values; p-values ≤ 0.05 were assumed to be statistically significant. CONCLUSION: The samples we measured showed a mean value of the diameters in Thermafil 25 that was 0.27 mm, for Thermafil 30 the mean value was 0.33 mm. We have measured a dimensional variable of 8% in the 25 group while in group 30 the maximum possible variation found was 4%, that’s why we propose a new protocol of obturation with thermafil. We can also conclude that a single heating process does not affect clinically the plastic carrier dimensions.
format Online
Article
Text
id pubmed-5838644
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Bentham Open
record_format MEDLINE/PubMed
spelling pubmed-58386442018-03-14 Thermafil: A New Clinical Approach Due to New Dimensional Evaluations Vittoria, G. Pantaleo, G. Blasi, A. Spagnuolo, G. Iandolo, A. Amato, M. Open Dent J Dentistry BACKGROUND: There are a lot of techniques to obturate the root canals, but lateral condensation of gutta-percha is the most used one. An important aspect of thermafil is the error margin tolerated by the manufacturer in the production of plastic carriers. In literature, there is no evidence about discrepancy percentage between different carriers. It is demonstrated that the error margin of gutta-percha is 0.5% and is 0.2% for metal files (ISO standards). OBJECTIVE: The aim of this study was to evaluate the real dimensions of thermafil plastic carriers observed by the stereo microscope measuring the dimensional discrepancy between them. METHODS: For this study, 80 new thermafil (Dentsply Maillefer) have been selected. 40 thermafil 0.25 and 40 thermafil 0.30. Through 60X stereo microscope, the dimensions of the plastic carrier tips have been measured. The dimensions of the plastic carrier were also measured after a heating cycle. ZL GAL 11TUSM (Zetaline stereo evolution) microscope was used to observe the samples. Measurements were made through a dedicated software (Image Focus). All samples were analysed at 60X. RESULTS: A non-parametric paired test (Wilcoxon test) was used to compare baseline and after heating values; p-values ≤ 0.05 were assumed to be statistically significant. CONCLUSION: The samples we measured showed a mean value of the diameters in Thermafil 25 that was 0.27 mm, for Thermafil 30 the mean value was 0.33 mm. We have measured a dimensional variable of 8% in the 25 group while in group 30 the maximum possible variation found was 4%, that’s why we propose a new protocol of obturation with thermafil. We can also conclude that a single heating process does not affect clinically the plastic carrier dimensions. Bentham Open 2018-02-22 /pmc/articles/PMC5838644/ /pubmed/29541263 http://dx.doi.org/10.2174/1874210601812010173 Text en © 2018 Vittoria et al. https://creativecommons.org/licenses/by/4.0/legalcode This is an open access article distributed under the terms of the Creative Commons Attribution 4.0 International Public License (CC-BY 4.0), a copy of which is available at: (https://creativecommons.org/licenses/by/4.0/legalcode). This license permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Dentistry
Vittoria, G.
Pantaleo, G.
Blasi, A.
Spagnuolo, G.
Iandolo, A.
Amato, M.
Thermafil: A New Clinical Approach Due to New Dimensional Evaluations
title Thermafil: A New Clinical Approach Due to New Dimensional Evaluations
title_full Thermafil: A New Clinical Approach Due to New Dimensional Evaluations
title_fullStr Thermafil: A New Clinical Approach Due to New Dimensional Evaluations
title_full_unstemmed Thermafil: A New Clinical Approach Due to New Dimensional Evaluations
title_short Thermafil: A New Clinical Approach Due to New Dimensional Evaluations
title_sort thermafil: a new clinical approach due to new dimensional evaluations
topic Dentistry
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5838644/
https://www.ncbi.nlm.nih.gov/pubmed/29541263
http://dx.doi.org/10.2174/1874210601812010173
work_keys_str_mv AT vittoriag thermafilanewclinicalapproachduetonewdimensionalevaluations
AT pantaleog thermafilanewclinicalapproachduetonewdimensionalevaluations
AT blasia thermafilanewclinicalapproachduetonewdimensionalevaluations
AT spagnuolog thermafilanewclinicalapproachduetonewdimensionalevaluations
AT iandoloa thermafilanewclinicalapproachduetonewdimensionalevaluations
AT amatom thermafilanewclinicalapproachduetonewdimensionalevaluations