Cargando…
Thermafil: A New Clinical Approach Due to New Dimensional Evaluations
BACKGROUND: There are a lot of techniques to obturate the root canals, but lateral condensation of gutta-percha is the most used one. An important aspect of thermafil is the error margin tolerated by the manufacturer in the production of plastic carriers. In literature, there is no evidence about di...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Bentham Open
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5838644/ https://www.ncbi.nlm.nih.gov/pubmed/29541263 http://dx.doi.org/10.2174/1874210601812010173 |
_version_ | 1783304291646177280 |
---|---|
author | Vittoria, G. Pantaleo, G. Blasi, A. Spagnuolo, G. Iandolo, A. Amato, M. |
author_facet | Vittoria, G. Pantaleo, G. Blasi, A. Spagnuolo, G. Iandolo, A. Amato, M. |
author_sort | Vittoria, G. |
collection | PubMed |
description | BACKGROUND: There are a lot of techniques to obturate the root canals, but lateral condensation of gutta-percha is the most used one. An important aspect of thermafil is the error margin tolerated by the manufacturer in the production of plastic carriers. In literature, there is no evidence about discrepancy percentage between different carriers. It is demonstrated that the error margin of gutta-percha is 0.5% and is 0.2% for metal files (ISO standards). OBJECTIVE: The aim of this study was to evaluate the real dimensions of thermafil plastic carriers observed by the stereo microscope measuring the dimensional discrepancy between them. METHODS: For this study, 80 new thermafil (Dentsply Maillefer) have been selected. 40 thermafil 0.25 and 40 thermafil 0.30. Through 60X stereo microscope, the dimensions of the plastic carrier tips have been measured. The dimensions of the plastic carrier were also measured after a heating cycle. ZL GAL 11TUSM (Zetaline stereo evolution) microscope was used to observe the samples. Measurements were made through a dedicated software (Image Focus). All samples were analysed at 60X. RESULTS: A non-parametric paired test (Wilcoxon test) was used to compare baseline and after heating values; p-values ≤ 0.05 were assumed to be statistically significant. CONCLUSION: The samples we measured showed a mean value of the diameters in Thermafil 25 that was 0.27 mm, for Thermafil 30 the mean value was 0.33 mm. We have measured a dimensional variable of 8% in the 25 group while in group 30 the maximum possible variation found was 4%, that’s why we propose a new protocol of obturation with thermafil. We can also conclude that a single heating process does not affect clinically the plastic carrier dimensions. |
format | Online Article Text |
id | pubmed-5838644 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Bentham Open |
record_format | MEDLINE/PubMed |
spelling | pubmed-58386442018-03-14 Thermafil: A New Clinical Approach Due to New Dimensional Evaluations Vittoria, G. Pantaleo, G. Blasi, A. Spagnuolo, G. Iandolo, A. Amato, M. Open Dent J Dentistry BACKGROUND: There are a lot of techniques to obturate the root canals, but lateral condensation of gutta-percha is the most used one. An important aspect of thermafil is the error margin tolerated by the manufacturer in the production of plastic carriers. In literature, there is no evidence about discrepancy percentage between different carriers. It is demonstrated that the error margin of gutta-percha is 0.5% and is 0.2% for metal files (ISO standards). OBJECTIVE: The aim of this study was to evaluate the real dimensions of thermafil plastic carriers observed by the stereo microscope measuring the dimensional discrepancy between them. METHODS: For this study, 80 new thermafil (Dentsply Maillefer) have been selected. 40 thermafil 0.25 and 40 thermafil 0.30. Through 60X stereo microscope, the dimensions of the plastic carrier tips have been measured. The dimensions of the plastic carrier were also measured after a heating cycle. ZL GAL 11TUSM (Zetaline stereo evolution) microscope was used to observe the samples. Measurements were made through a dedicated software (Image Focus). All samples were analysed at 60X. RESULTS: A non-parametric paired test (Wilcoxon test) was used to compare baseline and after heating values; p-values ≤ 0.05 were assumed to be statistically significant. CONCLUSION: The samples we measured showed a mean value of the diameters in Thermafil 25 that was 0.27 mm, for Thermafil 30 the mean value was 0.33 mm. We have measured a dimensional variable of 8% in the 25 group while in group 30 the maximum possible variation found was 4%, that’s why we propose a new protocol of obturation with thermafil. We can also conclude that a single heating process does not affect clinically the plastic carrier dimensions. Bentham Open 2018-02-22 /pmc/articles/PMC5838644/ /pubmed/29541263 http://dx.doi.org/10.2174/1874210601812010173 Text en © 2018 Vittoria et al. https://creativecommons.org/licenses/by/4.0/legalcode This is an open access article distributed under the terms of the Creative Commons Attribution 4.0 International Public License (CC-BY 4.0), a copy of which is available at: (https://creativecommons.org/licenses/by/4.0/legalcode). This license permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Dentistry Vittoria, G. Pantaleo, G. Blasi, A. Spagnuolo, G. Iandolo, A. Amato, M. Thermafil: A New Clinical Approach Due to New Dimensional Evaluations |
title | Thermafil: A New Clinical Approach Due to New Dimensional Evaluations |
title_full | Thermafil: A New Clinical Approach Due to New Dimensional Evaluations |
title_fullStr | Thermafil: A New Clinical Approach Due to New Dimensional Evaluations |
title_full_unstemmed | Thermafil: A New Clinical Approach Due to New Dimensional Evaluations |
title_short | Thermafil: A New Clinical Approach Due to New Dimensional Evaluations |
title_sort | thermafil: a new clinical approach due to new dimensional evaluations |
topic | Dentistry |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5838644/ https://www.ncbi.nlm.nih.gov/pubmed/29541263 http://dx.doi.org/10.2174/1874210601812010173 |
work_keys_str_mv | AT vittoriag thermafilanewclinicalapproachduetonewdimensionalevaluations AT pantaleog thermafilanewclinicalapproachduetonewdimensionalevaluations AT blasia thermafilanewclinicalapproachduetonewdimensionalevaluations AT spagnuolog thermafilanewclinicalapproachduetonewdimensionalevaluations AT iandoloa thermafilanewclinicalapproachduetonewdimensionalevaluations AT amatom thermafilanewclinicalapproachduetonewdimensionalevaluations |