Axial and oblique C2 pedicle diameters and feasibility of C2 pedicle screw placement: Technical note
BACKGROUND: For C2 pedicle screw placement/instrumentation, it is critical to adequately measure the axial and oblique C2 pedicle diameters utilizing the intraoperative O-arm. METHODS: Thirty-three patients who underwent C2 pedicle screw placement (2013–2016) utilizing the O-arm with tri-planar reco...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Medknow Publications & Media Pvt Ltd
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5838850/ https://www.ncbi.nlm.nih.gov/pubmed/29527398 http://dx.doi.org/10.4103/sni.sni_438_17 |
_version_ | 1783304315044102144 |
---|---|
author | Yin, Dali Oh, Gerald Neckrysh, Sergey |
author_facet | Yin, Dali Oh, Gerald Neckrysh, Sergey |
author_sort | Yin, Dali |
collection | PubMed |
description | BACKGROUND: For C2 pedicle screw placement/instrumentation, it is critical to adequately measure the axial and oblique C2 pedicle diameters utilizing the intraoperative O-arm. METHODS: Thirty-three patients who underwent C2 pedicle screw placement (2013–2016) utilizing the O-arm with tri-planar reconstruction. As O-arm software does not allow calibrated measurements with the application's measurement tool, we directly measured axial and oblique widths of the C2 pedicles on the screen with a regular ruler (e.g., “screen width of C2 pedicle”). RESULTS: The axial width of the C2 pedicles ranged from 6 to 15 mm on the right (mean 10.44 ± 2.15 mm) to 7 to 14 mm (10.29 ± 1.72 mm) on the left. The oblique width of C2 pedicles ranged from 10 to 19 mm on the right (mean, 14.73 ± 1.85 mm) and from 12 to 19 mm on the left (mean, of 15.33 ± 1.67 mm). These measurements indicated that oblique screen widths of the C2 pedicles were 1.4 and 1.5 times higher than their axial screen widths on the right and left sides, respectively. CONCLUSIONS: The oblique screen widths of the C2 pedicles better predict the feasibility of C2 pedicle screw placement vs. their axial screen width as measured with a regular ruler. |
format | Online Article Text |
id | pubmed-5838850 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Medknow Publications & Media Pvt Ltd |
record_format | MEDLINE/PubMed |
spelling | pubmed-58388502018-03-09 Axial and oblique C2 pedicle diameters and feasibility of C2 pedicle screw placement: Technical note Yin, Dali Oh, Gerald Neckrysh, Sergey Surg Neurol Int Spine: Technical Note BACKGROUND: For C2 pedicle screw placement/instrumentation, it is critical to adequately measure the axial and oblique C2 pedicle diameters utilizing the intraoperative O-arm. METHODS: Thirty-three patients who underwent C2 pedicle screw placement (2013–2016) utilizing the O-arm with tri-planar reconstruction. As O-arm software does not allow calibrated measurements with the application's measurement tool, we directly measured axial and oblique widths of the C2 pedicles on the screen with a regular ruler (e.g., “screen width of C2 pedicle”). RESULTS: The axial width of the C2 pedicles ranged from 6 to 15 mm on the right (mean 10.44 ± 2.15 mm) to 7 to 14 mm (10.29 ± 1.72 mm) on the left. The oblique width of C2 pedicles ranged from 10 to 19 mm on the right (mean, 14.73 ± 1.85 mm) and from 12 to 19 mm on the left (mean, of 15.33 ± 1.67 mm). These measurements indicated that oblique screen widths of the C2 pedicles were 1.4 and 1.5 times higher than their axial screen widths on the right and left sides, respectively. CONCLUSIONS: The oblique screen widths of the C2 pedicles better predict the feasibility of C2 pedicle screw placement vs. their axial screen width as measured with a regular ruler. Medknow Publications & Media Pvt Ltd 2018-02-16 /pmc/articles/PMC5838850/ /pubmed/29527398 http://dx.doi.org/10.4103/sni.sni_438_17 Text en Copyright: © 2018 Surgical Neurology International http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 3.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as the author is credited and the new creations are licensed under the identical terms. |
spellingShingle | Spine: Technical Note Yin, Dali Oh, Gerald Neckrysh, Sergey Axial and oblique C2 pedicle diameters and feasibility of C2 pedicle screw placement: Technical note |
title | Axial and oblique C2 pedicle diameters and feasibility of C2 pedicle screw placement: Technical note |
title_full | Axial and oblique C2 pedicle diameters and feasibility of C2 pedicle screw placement: Technical note |
title_fullStr | Axial and oblique C2 pedicle diameters and feasibility of C2 pedicle screw placement: Technical note |
title_full_unstemmed | Axial and oblique C2 pedicle diameters and feasibility of C2 pedicle screw placement: Technical note |
title_short | Axial and oblique C2 pedicle diameters and feasibility of C2 pedicle screw placement: Technical note |
title_sort | axial and oblique c2 pedicle diameters and feasibility of c2 pedicle screw placement: technical note |
topic | Spine: Technical Note |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5838850/ https://www.ncbi.nlm.nih.gov/pubmed/29527398 http://dx.doi.org/10.4103/sni.sni_438_17 |
work_keys_str_mv | AT yindali axialandobliquec2pediclediametersandfeasibilityofc2pediclescrewplacementtechnicalnote AT ohgerald axialandobliquec2pediclediametersandfeasibilityofc2pediclescrewplacementtechnicalnote AT neckryshsergey axialandobliquec2pediclediametersandfeasibilityofc2pediclescrewplacementtechnicalnote |