Cargando…

Axial and oblique C2 pedicle diameters and feasibility of C2 pedicle screw placement: Technical note

BACKGROUND: For C2 pedicle screw placement/instrumentation, it is critical to adequately measure the axial and oblique C2 pedicle diameters utilizing the intraoperative O-arm. METHODS: Thirty-three patients who underwent C2 pedicle screw placement (2013–2016) utilizing the O-arm with tri-planar reco...

Descripción completa

Detalles Bibliográficos
Autores principales: Yin, Dali, Oh, Gerald, Neckrysh, Sergey
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5838850/
https://www.ncbi.nlm.nih.gov/pubmed/29527398
http://dx.doi.org/10.4103/sni.sni_438_17
_version_ 1783304315044102144
author Yin, Dali
Oh, Gerald
Neckrysh, Sergey
author_facet Yin, Dali
Oh, Gerald
Neckrysh, Sergey
author_sort Yin, Dali
collection PubMed
description BACKGROUND: For C2 pedicle screw placement/instrumentation, it is critical to adequately measure the axial and oblique C2 pedicle diameters utilizing the intraoperative O-arm. METHODS: Thirty-three patients who underwent C2 pedicle screw placement (2013–2016) utilizing the O-arm with tri-planar reconstruction. As O-arm software does not allow calibrated measurements with the application's measurement tool, we directly measured axial and oblique widths of the C2 pedicles on the screen with a regular ruler (e.g., “screen width of C2 pedicle”). RESULTS: The axial width of the C2 pedicles ranged from 6 to 15 mm on the right (mean 10.44 ± 2.15 mm) to 7 to 14 mm (10.29 ± 1.72 mm) on the left. The oblique width of C2 pedicles ranged from 10 to 19 mm on the right (mean, 14.73 ± 1.85 mm) and from 12 to 19 mm on the left (mean, of 15.33 ± 1.67 mm). These measurements indicated that oblique screen widths of the C2 pedicles were 1.4 and 1.5 times higher than their axial screen widths on the right and left sides, respectively. CONCLUSIONS: The oblique screen widths of the C2 pedicles better predict the feasibility of C2 pedicle screw placement vs. their axial screen width as measured with a regular ruler.
format Online
Article
Text
id pubmed-5838850
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-58388502018-03-09 Axial and oblique C2 pedicle diameters and feasibility of C2 pedicle screw placement: Technical note Yin, Dali Oh, Gerald Neckrysh, Sergey Surg Neurol Int Spine: Technical Note BACKGROUND: For C2 pedicle screw placement/instrumentation, it is critical to adequately measure the axial and oblique C2 pedicle diameters utilizing the intraoperative O-arm. METHODS: Thirty-three patients who underwent C2 pedicle screw placement (2013–2016) utilizing the O-arm with tri-planar reconstruction. As O-arm software does not allow calibrated measurements with the application's measurement tool, we directly measured axial and oblique widths of the C2 pedicles on the screen with a regular ruler (e.g., “screen width of C2 pedicle”). RESULTS: The axial width of the C2 pedicles ranged from 6 to 15 mm on the right (mean 10.44 ± 2.15 mm) to 7 to 14 mm (10.29 ± 1.72 mm) on the left. The oblique width of C2 pedicles ranged from 10 to 19 mm on the right (mean, 14.73 ± 1.85 mm) and from 12 to 19 mm on the left (mean, of 15.33 ± 1.67 mm). These measurements indicated that oblique screen widths of the C2 pedicles were 1.4 and 1.5 times higher than their axial screen widths on the right and left sides, respectively. CONCLUSIONS: The oblique screen widths of the C2 pedicles better predict the feasibility of C2 pedicle screw placement vs. their axial screen width as measured with a regular ruler. Medknow Publications & Media Pvt Ltd 2018-02-16 /pmc/articles/PMC5838850/ /pubmed/29527398 http://dx.doi.org/10.4103/sni.sni_438_17 Text en Copyright: © 2018 Surgical Neurology International http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 3.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as the author is credited and the new creations are licensed under the identical terms.
spellingShingle Spine: Technical Note
Yin, Dali
Oh, Gerald
Neckrysh, Sergey
Axial and oblique C2 pedicle diameters and feasibility of C2 pedicle screw placement: Technical note
title Axial and oblique C2 pedicle diameters and feasibility of C2 pedicle screw placement: Technical note
title_full Axial and oblique C2 pedicle diameters and feasibility of C2 pedicle screw placement: Technical note
title_fullStr Axial and oblique C2 pedicle diameters and feasibility of C2 pedicle screw placement: Technical note
title_full_unstemmed Axial and oblique C2 pedicle diameters and feasibility of C2 pedicle screw placement: Technical note
title_short Axial and oblique C2 pedicle diameters and feasibility of C2 pedicle screw placement: Technical note
title_sort axial and oblique c2 pedicle diameters and feasibility of c2 pedicle screw placement: technical note
topic Spine: Technical Note
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5838850/
https://www.ncbi.nlm.nih.gov/pubmed/29527398
http://dx.doi.org/10.4103/sni.sni_438_17
work_keys_str_mv AT yindali axialandobliquec2pediclediametersandfeasibilityofc2pediclescrewplacementtechnicalnote
AT ohgerald axialandobliquec2pediclediametersandfeasibilityofc2pediclescrewplacementtechnicalnote
AT neckryshsergey axialandobliquec2pediclediametersandfeasibilityofc2pediclescrewplacementtechnicalnote