Cargando…

Discrimination of Voice Pitch and Vocal-Tract Length in Cochlear Implant Users

OBJECTIVES: When listening to two competing speakers, normal-hearing (NH) listeners can take advantage of voice differences between the speakers. Users of cochlear implants (CIs) have difficulty in perceiving speech on speech. Previous literature has indicated sensitivity to voice pitch (related to...

Descripción completa

Detalles Bibliográficos
Autores principales: Gaudrain, Etienne, Başkent, Deniz
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Williams And Wilkins 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5839701/
https://www.ncbi.nlm.nih.gov/pubmed/28799983
http://dx.doi.org/10.1097/AUD.0000000000000480
_version_ 1783304445938892800
author Gaudrain, Etienne
Başkent, Deniz
author_facet Gaudrain, Etienne
Başkent, Deniz
author_sort Gaudrain, Etienne
collection PubMed
description OBJECTIVES: When listening to two competing speakers, normal-hearing (NH) listeners can take advantage of voice differences between the speakers. Users of cochlear implants (CIs) have difficulty in perceiving speech on speech. Previous literature has indicated sensitivity to voice pitch (related to fundamental frequency, F0) to be poor among implant users, while sensitivity to vocal-tract length (VTL; related to the height of the speaker and formant frequencies), the other principal voice characteristic, has not been directly investigated in CIs. A few recent studies evaluated F0 and VTL perception indirectly, through voice gender categorization, which relies on perception of both voice cues. These studies revealed that, contrary to prior literature, CI users seem to rely exclusively on F0 while not utilizing VTL to perform this task. The objective of the present study was to directly and systematically assess raw sensitivity to F0 and VTL differences in CI users to define the extent of the deficit in voice perception. DESIGN: The just-noticeable differences (JNDs) for F0 and VTL were measured in 11 CI listeners using triplets of consonant–vowel syllables in an adaptive three-alternative forced choice method. RESULTS: The results showed that while NH listeners had average JNDs of 1.95 and 1.73 semitones (st) for F0 and VTL, respectively, CI listeners showed JNDs of 9.19 and 7.19 st. These JNDs correspond to differences of 70% in F0 and 52% in VTL. For comparison to the natural range of voices in the population, the F0 JND in CIs remains smaller than the typical male–female F0 difference. However, the average VTL JND in CIs is about twice as large as the typical male–female VTL difference. CONCLUSIONS: These findings, thus, directly confirm that CI listeners do not seem to have sufficient access to VTL cues, likely as a result of limited spectral resolution, and, hence, that CI listeners’ voice perception deficit goes beyond poor perception of F0. These results provide a potential common explanation not only for a number of deficits observed in CI listeners, such as voice identification and gender categorization, but also for competing speech perception.
format Online
Article
Text
id pubmed-5839701
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Williams And Wilkins
record_format MEDLINE/PubMed
spelling pubmed-58397012018-03-20 Discrimination of Voice Pitch and Vocal-Tract Length in Cochlear Implant Users Gaudrain, Etienne Başkent, Deniz Ear Hear Research Articles OBJECTIVES: When listening to two competing speakers, normal-hearing (NH) listeners can take advantage of voice differences between the speakers. Users of cochlear implants (CIs) have difficulty in perceiving speech on speech. Previous literature has indicated sensitivity to voice pitch (related to fundamental frequency, F0) to be poor among implant users, while sensitivity to vocal-tract length (VTL; related to the height of the speaker and formant frequencies), the other principal voice characteristic, has not been directly investigated in CIs. A few recent studies evaluated F0 and VTL perception indirectly, through voice gender categorization, which relies on perception of both voice cues. These studies revealed that, contrary to prior literature, CI users seem to rely exclusively on F0 while not utilizing VTL to perform this task. The objective of the present study was to directly and systematically assess raw sensitivity to F0 and VTL differences in CI users to define the extent of the deficit in voice perception. DESIGN: The just-noticeable differences (JNDs) for F0 and VTL were measured in 11 CI listeners using triplets of consonant–vowel syllables in an adaptive three-alternative forced choice method. RESULTS: The results showed that while NH listeners had average JNDs of 1.95 and 1.73 semitones (st) for F0 and VTL, respectively, CI listeners showed JNDs of 9.19 and 7.19 st. These JNDs correspond to differences of 70% in F0 and 52% in VTL. For comparison to the natural range of voices in the population, the F0 JND in CIs remains smaller than the typical male–female F0 difference. However, the average VTL JND in CIs is about twice as large as the typical male–female VTL difference. CONCLUSIONS: These findings, thus, directly confirm that CI listeners do not seem to have sufficient access to VTL cues, likely as a result of limited spectral resolution, and, hence, that CI listeners’ voice perception deficit goes beyond poor perception of F0. These results provide a potential common explanation not only for a number of deficits observed in CI listeners, such as voice identification and gender categorization, but also for competing speech perception. Williams And Wilkins 2018-03 2018-02-23 /pmc/articles/PMC5839701/ /pubmed/28799983 http://dx.doi.org/10.1097/AUD.0000000000000480 Text en Copyright © 2017 The Author(s). Ear & Hearing is published on behalf of the American Auditory Society, by Wolters Kluwer Health, Inc. This is an open-access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (CCBY-NC-ND) (http://creativecommons.org/licenses/by-nc-nd/4.0/) , where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially without permission from the journal.
spellingShingle Research Articles
Gaudrain, Etienne
Başkent, Deniz
Discrimination of Voice Pitch and Vocal-Tract Length in Cochlear Implant Users
title Discrimination of Voice Pitch and Vocal-Tract Length in Cochlear Implant Users
title_full Discrimination of Voice Pitch and Vocal-Tract Length in Cochlear Implant Users
title_fullStr Discrimination of Voice Pitch and Vocal-Tract Length in Cochlear Implant Users
title_full_unstemmed Discrimination of Voice Pitch and Vocal-Tract Length in Cochlear Implant Users
title_short Discrimination of Voice Pitch and Vocal-Tract Length in Cochlear Implant Users
title_sort discrimination of voice pitch and vocal-tract length in cochlear implant users
topic Research Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5839701/
https://www.ncbi.nlm.nih.gov/pubmed/28799983
http://dx.doi.org/10.1097/AUD.0000000000000480
work_keys_str_mv AT gaudrainetienne discriminationofvoicepitchandvocaltractlengthincochlearimplantusers
AT baskentdeniz discriminationofvoicepitchandvocaltractlengthincochlearimplantusers