Cargando…

Endoscopic bronchial occlusion for postoperative persistent bronchopleural fistula with computed tomography fluoroscopy guidance and virtual bronchoscopic navigation: A case report

RATIONALE: The development of postoperative bronchopleural fistula (BPF) remains a challenge in thoracic surgery. We herein report a case of BPF successfully treated with endoscopic bronchial occlusion under computed tomography (CT) fluoroscopy and virtual bronchoscopic navigation (VBN). PATIENT CON...

Descripción completa

Detalles Bibliográficos
Autores principales: Yanagiya, Masahiro, Matsumoto, Jun, Nagano, Masaaki, Kusakabe, Masashi, Matsumoto, Yoko, Furukawa, Ryutaro, Ohara, Sayaka, Usui, Kazuhiro
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer Health 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5839832/
https://www.ncbi.nlm.nih.gov/pubmed/29443771
http://dx.doi.org/10.1097/MD.0000000000009921
_version_ 1783304473188237312
author Yanagiya, Masahiro
Matsumoto, Jun
Nagano, Masaaki
Kusakabe, Masashi
Matsumoto, Yoko
Furukawa, Ryutaro
Ohara, Sayaka
Usui, Kazuhiro
author_facet Yanagiya, Masahiro
Matsumoto, Jun
Nagano, Masaaki
Kusakabe, Masashi
Matsumoto, Yoko
Furukawa, Ryutaro
Ohara, Sayaka
Usui, Kazuhiro
author_sort Yanagiya, Masahiro
collection PubMed
description RATIONALE: The development of postoperative bronchopleural fistula (BPF) remains a challenge in thoracic surgery. We herein report a case of BPF successfully treated with endoscopic bronchial occlusion under computed tomography (CT) fluoroscopy and virtual bronchoscopic navigation (VBN). PATIENT CONCERNS: A 63-year-old man underwent right upper lobectomy with concomitant S6a subsegmentectomy for lung adenocarcinoma. On postoperative day 24, he complained of shaking chills with high fever. DIAGNOSES: BPF with subsequent pneumonia and empyema. INTERVENTIONS: Despite aggressive surgical interventions for the BPF, air leakage persisted postoperatively. On days 26 and 34 after the final operation, endobronchial occlusions were performed under CT fluoroscopy and VBN. OUTCOMES: The air leaks greatly decreased and the patient was discharged. LESSONS: CT fluoroscopy and VBN can be useful techniques for endobronchial occlusion in the treatment of BPF.
format Online
Article
Text
id pubmed-5839832
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Wolters Kluwer Health
record_format MEDLINE/PubMed
spelling pubmed-58398322018-03-13 Endoscopic bronchial occlusion for postoperative persistent bronchopleural fistula with computed tomography fluoroscopy guidance and virtual bronchoscopic navigation: A case report Yanagiya, Masahiro Matsumoto, Jun Nagano, Masaaki Kusakabe, Masashi Matsumoto, Yoko Furukawa, Ryutaro Ohara, Sayaka Usui, Kazuhiro Medicine (Baltimore) 6700 RATIONALE: The development of postoperative bronchopleural fistula (BPF) remains a challenge in thoracic surgery. We herein report a case of BPF successfully treated with endoscopic bronchial occlusion under computed tomography (CT) fluoroscopy and virtual bronchoscopic navigation (VBN). PATIENT CONCERNS: A 63-year-old man underwent right upper lobectomy with concomitant S6a subsegmentectomy for lung adenocarcinoma. On postoperative day 24, he complained of shaking chills with high fever. DIAGNOSES: BPF with subsequent pneumonia and empyema. INTERVENTIONS: Despite aggressive surgical interventions for the BPF, air leakage persisted postoperatively. On days 26 and 34 after the final operation, endobronchial occlusions were performed under CT fluoroscopy and VBN. OUTCOMES: The air leaks greatly decreased and the patient was discharged. LESSONS: CT fluoroscopy and VBN can be useful techniques for endobronchial occlusion in the treatment of BPF. Wolters Kluwer Health 2018-02-16 /pmc/articles/PMC5839832/ /pubmed/29443771 http://dx.doi.org/10.1097/MD.0000000000009921 Text en Copyright © 2018 the Author(s). Published by Wolters Kluwer Health, Inc. http://creativecommons.org/licenses/by-sa/4.0 This is an open access article distributed under the Creative Commons Attribution-ShareAlike License 4.0, which allows others to remix, tweak, and build upon the work, even for commercial purposes, as long as the author is credited and the new creations are licensed under the identical terms. http://creativecommons.org/licenses/by-sa/4.0
spellingShingle 6700
Yanagiya, Masahiro
Matsumoto, Jun
Nagano, Masaaki
Kusakabe, Masashi
Matsumoto, Yoko
Furukawa, Ryutaro
Ohara, Sayaka
Usui, Kazuhiro
Endoscopic bronchial occlusion for postoperative persistent bronchopleural fistula with computed tomography fluoroscopy guidance and virtual bronchoscopic navigation: A case report
title Endoscopic bronchial occlusion for postoperative persistent bronchopleural fistula with computed tomography fluoroscopy guidance and virtual bronchoscopic navigation: A case report
title_full Endoscopic bronchial occlusion for postoperative persistent bronchopleural fistula with computed tomography fluoroscopy guidance and virtual bronchoscopic navigation: A case report
title_fullStr Endoscopic bronchial occlusion for postoperative persistent bronchopleural fistula with computed tomography fluoroscopy guidance and virtual bronchoscopic navigation: A case report
title_full_unstemmed Endoscopic bronchial occlusion for postoperative persistent bronchopleural fistula with computed tomography fluoroscopy guidance and virtual bronchoscopic navigation: A case report
title_short Endoscopic bronchial occlusion for postoperative persistent bronchopleural fistula with computed tomography fluoroscopy guidance and virtual bronchoscopic navigation: A case report
title_sort endoscopic bronchial occlusion for postoperative persistent bronchopleural fistula with computed tomography fluoroscopy guidance and virtual bronchoscopic navigation: a case report
topic 6700
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5839832/
https://www.ncbi.nlm.nih.gov/pubmed/29443771
http://dx.doi.org/10.1097/MD.0000000000009921
work_keys_str_mv AT yanagiyamasahiro endoscopicbronchialocclusionforpostoperativepersistentbronchopleuralfistulawithcomputedtomographyfluoroscopyguidanceandvirtualbronchoscopicnavigationacasereport
AT matsumotojun endoscopicbronchialocclusionforpostoperativepersistentbronchopleuralfistulawithcomputedtomographyfluoroscopyguidanceandvirtualbronchoscopicnavigationacasereport
AT naganomasaaki endoscopicbronchialocclusionforpostoperativepersistentbronchopleuralfistulawithcomputedtomographyfluoroscopyguidanceandvirtualbronchoscopicnavigationacasereport
AT kusakabemasashi endoscopicbronchialocclusionforpostoperativepersistentbronchopleuralfistulawithcomputedtomographyfluoroscopyguidanceandvirtualbronchoscopicnavigationacasereport
AT matsumotoyoko endoscopicbronchialocclusionforpostoperativepersistentbronchopleuralfistulawithcomputedtomographyfluoroscopyguidanceandvirtualbronchoscopicnavigationacasereport
AT furukawaryutaro endoscopicbronchialocclusionforpostoperativepersistentbronchopleuralfistulawithcomputedtomographyfluoroscopyguidanceandvirtualbronchoscopicnavigationacasereport
AT oharasayaka endoscopicbronchialocclusionforpostoperativepersistentbronchopleuralfistulawithcomputedtomographyfluoroscopyguidanceandvirtualbronchoscopicnavigationacasereport
AT usuikazuhiro endoscopicbronchialocclusionforpostoperativepersistentbronchopleuralfistulawithcomputedtomographyfluoroscopyguidanceandvirtualbronchoscopicnavigationacasereport