It is essential to build a system to generate proper neural stimulus signals with adjusting parameters. We developed a stimulator with up to four channels for separate settings in periodic and non-periodic modes. The device can support a closed-loop experimental system which utilizes neural informat...

Descripción completa

Detalles Bibliográficos
Autores principales: An, Hyejin, Shin, Hyun-Chool
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Society for Brain and Neural Science 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5840462/
https://www.ncbi.nlm.nih.gov/pubmed/29535570
http://dx.doi.org/10.5607/en.2018.27.1.57
_version_ 1783304585318760448
author An, Hyejin
Shin, Hyun-Chool
author_facet An, Hyejin
Shin, Hyun-Chool
author_sort An, Hyejin
collection PubMed
description It is essential to build a system to generate proper neural stimulus signals with adjusting parameters. We developed a stimulator with up to four channels for separate settings in periodic and non-periodic modes. The device can support a closed-loop experimental system which utilizes neural information in real time as a feedback for controlling stimuli. To confirm whether stimulating signals are properly produced and delivered inside the brain, two experiments with rats were conducted. We observed that the change of firing rates and the cross-power spectral density increased after stimulation which meant that electric signals were transferred well and that they affected the neurons' activities. Thus, it is expected that the stimulator can be utilized to produce appropriate stimulation signals in accordance with various objectives.
format Online
Article
Text
id pubmed-5840462
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher The Korean Society for Brain and Neural Science
record_format MEDLINE/PubMed
spelling pubmed-58404622018-03-13 Development of Electrical Neural Stimulator Generating Periodic and Non-periodic Signals and Supporting Closed-loop Experimental System An, Hyejin Shin, Hyun-Chool Exp Neurobiol Technologue It is essential to build a system to generate proper neural stimulus signals with adjusting parameters. We developed a stimulator with up to four channels for separate settings in periodic and non-periodic modes. The device can support a closed-loop experimental system which utilizes neural information in real time as a feedback for controlling stimuli. To confirm whether stimulating signals are properly produced and delivered inside the brain, two experiments with rats were conducted. We observed that the change of firing rates and the cross-power spectral density increased after stimulation which meant that electric signals were transferred well and that they affected the neurons' activities. Thus, it is expected that the stimulator can be utilized to produce appropriate stimulation signals in accordance with various objectives. The Korean Society for Brain and Neural Science 2018-02 2018-02-26 /pmc/articles/PMC5840462/ /pubmed/29535570 http://dx.doi.org/10.5607/en.2018.27.1.57 Text en Copyright © Experimental Neurobiology 2017. http://creativecommons.org/licenses/by-nc/4.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Technologue
An, Hyejin
Shin, Hyun-Chool
Development of Electrical Neural Stimulator Generating Periodic and Non-periodic Signals and Supporting Closed-loop Experimental System
title Development of Electrical Neural Stimulator Generating Periodic and Non-periodic Signals and Supporting Closed-loop Experimental System
title_full Development of Electrical Neural Stimulator Generating Periodic and Non-periodic Signals and Supporting Closed-loop Experimental System
title_fullStr Development of Electrical Neural Stimulator Generating Periodic and Non-periodic Signals and Supporting Closed-loop Experimental System
title_full_unstemmed Development of Electrical Neural Stimulator Generating Periodic and Non-periodic Signals and Supporting Closed-loop Experimental System
title_short Development of Electrical Neural Stimulator Generating Periodic and Non-periodic Signals and Supporting Closed-loop Experimental System
title_sort development of electrical neural stimulator generating periodic and non-periodic signals and supporting closed-loop experimental system
topic Technologue
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5840462/
https://www.ncbi.nlm.nih.gov/pubmed/29535570
http://dx.doi.org/10.5607/en.2018.27.1.57
work_keys_str_mv AT anhyejin developmentofelectricalneuralstimulatorgeneratingperiodicandnonperiodicsignalsandsupportingclosedloopexperimentalsystem
AT shinhyunchool developmentofelectricalneuralstimulatorgeneratingperiodicandnonperiodicsignalsandsupportingclosedloopexperimentalsystem