Cargando…

A preliminary study evaluating cardiac output measurement using Pressure Recording Analytical Method (PRAM) in anaesthetized dogs

BACKGROUND: Haemodynamic variations normally occur in anaesthetized animals, in relation to the animal status, administered drugs, sympathetic and parasympathetic tone, fluid therapy and surgical stimulus. The possibility to measure some cardiovascular parameters, such as cardiac output (CO), during...

Descripción completa

Detalles Bibliográficos
Autores principales: Briganti, Angela, Evangelista, Flavia, Centonze, Paola, Rizzo, Annaliso, Bentivegna, Francesco, Crovace, Antonio, Staffieri, Francesco
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5840695/
https://www.ncbi.nlm.nih.gov/pubmed/29510691
http://dx.doi.org/10.1186/s12917-018-1392-5
_version_ 1783304626196447232
author Briganti, Angela
Evangelista, Flavia
Centonze, Paola
Rizzo, Annaliso
Bentivegna, Francesco
Crovace, Antonio
Staffieri, Francesco
author_facet Briganti, Angela
Evangelista, Flavia
Centonze, Paola
Rizzo, Annaliso
Bentivegna, Francesco
Crovace, Antonio
Staffieri, Francesco
author_sort Briganti, Angela
collection PubMed
description BACKGROUND: Haemodynamic variations normally occur in anaesthetized animals, in relation to the animal status, administered drugs, sympathetic and parasympathetic tone, fluid therapy and surgical stimulus. The possibility to measure some cardiovascular parameters, such as cardiac output (CO), during anaesthesia would be beneficial for both the anaesthesia management and its outcome. New techniques for the monitoring of CO are aimed at finding methods which are non invasive, accurate and with good trending ability, which can be used in a clinical setting. The aim of this study was to compare the Pressure Recording Analytical Method (PRAM) with the pulmonary artery thermodilution (TD) for the measurement of cardiac output in 6 anaesthetized critically ill dogs. RESULTS: Fifty-four pairs of CO measurements were obtained with a median (range) of 3.33 L/min (0.81–7.21) for PRAM-CO and 3.48 L/min (1.41–6.56) for TD-CO. The Bland-Altman analysis showed a mean bias of 0.17 L/min with limits of agreement (LoA) of − 0.46 to 0.81 L/min. The percentage error resulted 18.2%. The 4-quadrant plot analysis showed an acceptable concordance (93%) between the 2 methods. The polar plot showed a good trending ability with the mean angular bias of 3.9° and radial LoA ± 12.1°. CONCLUSIONS: The PRAM resulted in good precision, acceptable concordance and good trending ability for the measure of CO in the anaesthetized dog, representing a promising alternative to thermodilution for the measurement of CO. Among all the pulse contour methods available on the market it is the only one that does not require any calibration or adjustment of the measurement. Further studies are required to verify the ability of this method to accurately measure cardiac output even during unstable hemodynamic conditions.
format Online
Article
Text
id pubmed-5840695
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-58406952018-03-09 A preliminary study evaluating cardiac output measurement using Pressure Recording Analytical Method (PRAM) in anaesthetized dogs Briganti, Angela Evangelista, Flavia Centonze, Paola Rizzo, Annaliso Bentivegna, Francesco Crovace, Antonio Staffieri, Francesco BMC Vet Res Research Article BACKGROUND: Haemodynamic variations normally occur in anaesthetized animals, in relation to the animal status, administered drugs, sympathetic and parasympathetic tone, fluid therapy and surgical stimulus. The possibility to measure some cardiovascular parameters, such as cardiac output (CO), during anaesthesia would be beneficial for both the anaesthesia management and its outcome. New techniques for the monitoring of CO are aimed at finding methods which are non invasive, accurate and with good trending ability, which can be used in a clinical setting. The aim of this study was to compare the Pressure Recording Analytical Method (PRAM) with the pulmonary artery thermodilution (TD) for the measurement of cardiac output in 6 anaesthetized critically ill dogs. RESULTS: Fifty-four pairs of CO measurements were obtained with a median (range) of 3.33 L/min (0.81–7.21) for PRAM-CO and 3.48 L/min (1.41–6.56) for TD-CO. The Bland-Altman analysis showed a mean bias of 0.17 L/min with limits of agreement (LoA) of − 0.46 to 0.81 L/min. The percentage error resulted 18.2%. The 4-quadrant plot analysis showed an acceptable concordance (93%) between the 2 methods. The polar plot showed a good trending ability with the mean angular bias of 3.9° and radial LoA ± 12.1°. CONCLUSIONS: The PRAM resulted in good precision, acceptable concordance and good trending ability for the measure of CO in the anaesthetized dog, representing a promising alternative to thermodilution for the measurement of CO. Among all the pulse contour methods available on the market it is the only one that does not require any calibration or adjustment of the measurement. Further studies are required to verify the ability of this method to accurately measure cardiac output even during unstable hemodynamic conditions. BioMed Central 2018-03-06 /pmc/articles/PMC5840695/ /pubmed/29510691 http://dx.doi.org/10.1186/s12917-018-1392-5 Text en © The Author(s). 2018 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research Article
Briganti, Angela
Evangelista, Flavia
Centonze, Paola
Rizzo, Annaliso
Bentivegna, Francesco
Crovace, Antonio
Staffieri, Francesco
A preliminary study evaluating cardiac output measurement using Pressure Recording Analytical Method (PRAM) in anaesthetized dogs
title A preliminary study evaluating cardiac output measurement using Pressure Recording Analytical Method (PRAM) in anaesthetized dogs
title_full A preliminary study evaluating cardiac output measurement using Pressure Recording Analytical Method (PRAM) in anaesthetized dogs
title_fullStr A preliminary study evaluating cardiac output measurement using Pressure Recording Analytical Method (PRAM) in anaesthetized dogs
title_full_unstemmed A preliminary study evaluating cardiac output measurement using Pressure Recording Analytical Method (PRAM) in anaesthetized dogs
title_short A preliminary study evaluating cardiac output measurement using Pressure Recording Analytical Method (PRAM) in anaesthetized dogs
title_sort preliminary study evaluating cardiac output measurement using pressure recording analytical method (pram) in anaesthetized dogs
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5840695/
https://www.ncbi.nlm.nih.gov/pubmed/29510691
http://dx.doi.org/10.1186/s12917-018-1392-5
work_keys_str_mv AT brigantiangela apreliminarystudyevaluatingcardiacoutputmeasurementusingpressurerecordinganalyticalmethodpraminanaesthetizeddogs
AT evangelistaflavia apreliminarystudyevaluatingcardiacoutputmeasurementusingpressurerecordinganalyticalmethodpraminanaesthetizeddogs
AT centonzepaola apreliminarystudyevaluatingcardiacoutputmeasurementusingpressurerecordinganalyticalmethodpraminanaesthetizeddogs
AT rizzoannaliso apreliminarystudyevaluatingcardiacoutputmeasurementusingpressurerecordinganalyticalmethodpraminanaesthetizeddogs
AT bentivegnafrancesco apreliminarystudyevaluatingcardiacoutputmeasurementusingpressurerecordinganalyticalmethodpraminanaesthetizeddogs
AT crovaceantonio apreliminarystudyevaluatingcardiacoutputmeasurementusingpressurerecordinganalyticalmethodpraminanaesthetizeddogs
AT staffierifrancesco apreliminarystudyevaluatingcardiacoutputmeasurementusingpressurerecordinganalyticalmethodpraminanaesthetizeddogs
AT brigantiangela preliminarystudyevaluatingcardiacoutputmeasurementusingpressurerecordinganalyticalmethodpraminanaesthetizeddogs
AT evangelistaflavia preliminarystudyevaluatingcardiacoutputmeasurementusingpressurerecordinganalyticalmethodpraminanaesthetizeddogs
AT centonzepaola preliminarystudyevaluatingcardiacoutputmeasurementusingpressurerecordinganalyticalmethodpraminanaesthetizeddogs
AT rizzoannaliso preliminarystudyevaluatingcardiacoutputmeasurementusingpressurerecordinganalyticalmethodpraminanaesthetizeddogs
AT bentivegnafrancesco preliminarystudyevaluatingcardiacoutputmeasurementusingpressurerecordinganalyticalmethodpraminanaesthetizeddogs
AT crovaceantonio preliminarystudyevaluatingcardiacoutputmeasurementusingpressurerecordinganalyticalmethodpraminanaesthetizeddogs
AT staffierifrancesco preliminarystudyevaluatingcardiacoutputmeasurementusingpressurerecordinganalyticalmethodpraminanaesthetizeddogs