Acute Perioperative Comparison of Patient-Specific Instrumentation versus Conventional Instrumentation Utilization during Bilateral Total Knee Arthroplasty
Utilizing patient-specific instrumentation during total knee arthroplasty has gained popularity in recent years with theoretical advantages in blood loss, intraoperative time, length of stay, postoperative alignment, and functional outcome, amongst others. No study has compared acute perioperative m...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5841073/ https://www.ncbi.nlm.nih.gov/pubmed/29682602 http://dx.doi.org/10.1155/2018/9326459 |
_version_ | 1783304693761441792 |
---|---|
author | Steimle, Jerrod A. Groover, Michael T. Webb, Brad A. Ceccarelli, Brian J. |
author_facet | Steimle, Jerrod A. Groover, Michael T. Webb, Brad A. Ceccarelli, Brian J. |
author_sort | Steimle, Jerrod A. |
collection | PubMed |
description | Utilizing patient-specific instrumentation during total knee arthroplasty has gained popularity in recent years with theoretical advantages in blood loss, intraoperative time, length of stay, postoperative alignment, and functional outcome, amongst others. No study has compared acute perioperative measures between patient-specific instrumentation and conventional instrumentation in the bilateral total knee arthroplasty setting. We compared patient-specific instrumentation versus conventional instrumentation in the setting of bilateral total knee arthroplasty to determine any benefits in the immediate perioperative period including surgical time, blood loss, pain medication use, length of stay, and discharge disposition. A total of 49 patients with standard instrumentation and 31 patients with patient-specific instrumentation were retrospectively reviewed in a two-year period at one facility. At baseline, the groups were comparable with respect to age, ASA, BMI, and comorbid conditions. We analyzed data on operative time, blood loss, hemoglobin change, need for transfusion, pain medication use, length of stay, and discharge disposition. There was no statistically significant difference between groups in regards to these parameters. Patient-specific instrumentation in the setting of bilateral total knee arthroplasty did not provide any immediate perioperative benefit compared to conventional instrumentation. |
format | Online Article Text |
id | pubmed-5841073 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Hindawi |
record_format | MEDLINE/PubMed |
spelling | pubmed-58410732018-04-21 Acute Perioperative Comparison of Patient-Specific Instrumentation versus Conventional Instrumentation Utilization during Bilateral Total Knee Arthroplasty Steimle, Jerrod A. Groover, Michael T. Webb, Brad A. Ceccarelli, Brian J. Surg Res Pract Research Article Utilizing patient-specific instrumentation during total knee arthroplasty has gained popularity in recent years with theoretical advantages in blood loss, intraoperative time, length of stay, postoperative alignment, and functional outcome, amongst others. No study has compared acute perioperative measures between patient-specific instrumentation and conventional instrumentation in the bilateral total knee arthroplasty setting. We compared patient-specific instrumentation versus conventional instrumentation in the setting of bilateral total knee arthroplasty to determine any benefits in the immediate perioperative period including surgical time, blood loss, pain medication use, length of stay, and discharge disposition. A total of 49 patients with standard instrumentation and 31 patients with patient-specific instrumentation were retrospectively reviewed in a two-year period at one facility. At baseline, the groups were comparable with respect to age, ASA, BMI, and comorbid conditions. We analyzed data on operative time, blood loss, hemoglobin change, need for transfusion, pain medication use, length of stay, and discharge disposition. There was no statistically significant difference between groups in regards to these parameters. Patient-specific instrumentation in the setting of bilateral total knee arthroplasty did not provide any immediate perioperative benefit compared to conventional instrumentation. Hindawi 2018-02-21 /pmc/articles/PMC5841073/ /pubmed/29682602 http://dx.doi.org/10.1155/2018/9326459 Text en Copyright © 2018 Jerrod A. Steimle et al. http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Steimle, Jerrod A. Groover, Michael T. Webb, Brad A. Ceccarelli, Brian J. Acute Perioperative Comparison of Patient-Specific Instrumentation versus Conventional Instrumentation Utilization during Bilateral Total Knee Arthroplasty |
title | Acute Perioperative Comparison of Patient-Specific Instrumentation versus Conventional Instrumentation Utilization during Bilateral Total Knee Arthroplasty |
title_full | Acute Perioperative Comparison of Patient-Specific Instrumentation versus Conventional Instrumentation Utilization during Bilateral Total Knee Arthroplasty |
title_fullStr | Acute Perioperative Comparison of Patient-Specific Instrumentation versus Conventional Instrumentation Utilization during Bilateral Total Knee Arthroplasty |
title_full_unstemmed | Acute Perioperative Comparison of Patient-Specific Instrumentation versus Conventional Instrumentation Utilization during Bilateral Total Knee Arthroplasty |
title_short | Acute Perioperative Comparison of Patient-Specific Instrumentation versus Conventional Instrumentation Utilization during Bilateral Total Knee Arthroplasty |
title_sort | acute perioperative comparison of patient-specific instrumentation versus conventional instrumentation utilization during bilateral total knee arthroplasty |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5841073/ https://www.ncbi.nlm.nih.gov/pubmed/29682602 http://dx.doi.org/10.1155/2018/9326459 |
work_keys_str_mv | AT steimlejerroda acuteperioperativecomparisonofpatientspecificinstrumentationversusconventionalinstrumentationutilizationduringbilateraltotalkneearthroplasty AT groovermichaelt acuteperioperativecomparisonofpatientspecificinstrumentationversusconventionalinstrumentationutilizationduringbilateraltotalkneearthroplasty AT webbbrada acuteperioperativecomparisonofpatientspecificinstrumentationversusconventionalinstrumentationutilizationduringbilateraltotalkneearthroplasty AT ceccarellibrianj acuteperioperativecomparisonofpatientspecificinstrumentationversusconventionalinstrumentationutilizationduringbilateraltotalkneearthroplasty |