Cargando…

Clinical Feasibility of Continuously Monitored Data for Heart Rate, Physical Activity, and Sleeping by Wearable Activity Trackers in Patients with Thyrotoxicosis: Protocol for a Prospective Longitudinal Observational Study

BACKGROUND: Thyrotoxicosis is a common disease caused by an excess of thyroid hormones. The prevalence of thyrotoxicosis about 2% and 70-90% of thyrotoxicosis cases are caused by Graves' disease, an autoimmune disease, which has a high recurrence rate when treated with antithyroid drugs such as...

Descripción completa

Detalles Bibliográficos
Autores principales: Lee, Jie-Eun, Lee, Dong Hwa, Oh, Tae Jung, Kim, Kyoung Min, Choi, Sung Hee, Lim, Soo, Park, Young Joo, Park, Do Joon, Jang, Hak Chul, Moon, Jae Hoon
Formato: Online Artículo Texto
Lenguaje:English
Publicado: JMIR Publications 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5842324/
https://www.ncbi.nlm.nih.gov/pubmed/29467121
http://dx.doi.org/10.2196/resprot.8119
_version_ 1783304878611759104
author Lee, Jie-Eun
Lee, Dong Hwa
Oh, Tae Jung
Kim, Kyoung Min
Choi, Sung Hee
Lim, Soo
Park, Young Joo
Park, Do Joon
Jang, Hak Chul
Moon, Jae Hoon
author_facet Lee, Jie-Eun
Lee, Dong Hwa
Oh, Tae Jung
Kim, Kyoung Min
Choi, Sung Hee
Lim, Soo
Park, Young Joo
Park, Do Joon
Jang, Hak Chul
Moon, Jae Hoon
author_sort Lee, Jie-Eun
collection PubMed
description BACKGROUND: Thyrotoxicosis is a common disease caused by an excess of thyroid hormones. The prevalence of thyrotoxicosis about 2% and 70-90% of thyrotoxicosis cases are caused by Graves' disease, an autoimmune disease, which has a high recurrence rate when treated with antithyroid drugs such as methimazole or propylthiouracil. The clinical symptoms and signs of thyrotoxicosis include palpitation, weight loss, restlessness, and difficulty sleeping. Although these clinical changes in thyrotoxicosis can be detected by currently available wearable activity trackers, there have been few trials of the clinical application of wearable devices in patients with thyrotoxicosis. OBJECTIVE: The aim of this study is to investigate the clinical applicability of wearable device-generated data to the management of thyrotoxicosis. We are analyzing continuously monitored data for heart rate, physical activity, and sleep in patients with thyrotoxicosis during their clinical course after treatment. METHODS: Thirty thyrotoxic patients and 10 control subjects were enrolled in this study at Seoul National University Bundang Hospital. Heart rate, physical activity, and sleep are being monitored using a Fitbit Charge HR or Fitbit Charge 2. Clinical data including anthropometric measures, thyroid function test, and hyperthyroidism symptom scale are recorded. RESULTS: Study enrollment began in December 2016, and the intervention and follow-up phases are ongoing. The results of the data analysis are expected to be available by September 2017. CONCLUSIONS: This study will provide a foundational feasibility trial of the clinical applications of biosignal measurements to the differential diagnosis, prediction of clinical course, early detection of recurrence, and treatment in patients with thyrotoxicosis. TRIAL REGISTRATION: ClinicalTrials.gov NCT03009357; https://clinicaltrials.gov/ct2/show/NCT03009357 (Archived by WebCite at http://www.webcitation.org/6wh4MWPm2)
format Online
Article
Text
id pubmed-5842324
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher JMIR Publications
record_format MEDLINE/PubMed
spelling pubmed-58423242018-03-09 Clinical Feasibility of Continuously Monitored Data for Heart Rate, Physical Activity, and Sleeping by Wearable Activity Trackers in Patients with Thyrotoxicosis: Protocol for a Prospective Longitudinal Observational Study Lee, Jie-Eun Lee, Dong Hwa Oh, Tae Jung Kim, Kyoung Min Choi, Sung Hee Lim, Soo Park, Young Joo Park, Do Joon Jang, Hak Chul Moon, Jae Hoon JMIR Res Protoc Protocol BACKGROUND: Thyrotoxicosis is a common disease caused by an excess of thyroid hormones. The prevalence of thyrotoxicosis about 2% and 70-90% of thyrotoxicosis cases are caused by Graves' disease, an autoimmune disease, which has a high recurrence rate when treated with antithyroid drugs such as methimazole or propylthiouracil. The clinical symptoms and signs of thyrotoxicosis include palpitation, weight loss, restlessness, and difficulty sleeping. Although these clinical changes in thyrotoxicosis can be detected by currently available wearable activity trackers, there have been few trials of the clinical application of wearable devices in patients with thyrotoxicosis. OBJECTIVE: The aim of this study is to investigate the clinical applicability of wearable device-generated data to the management of thyrotoxicosis. We are analyzing continuously monitored data for heart rate, physical activity, and sleep in patients with thyrotoxicosis during their clinical course after treatment. METHODS: Thirty thyrotoxic patients and 10 control subjects were enrolled in this study at Seoul National University Bundang Hospital. Heart rate, physical activity, and sleep are being monitored using a Fitbit Charge HR or Fitbit Charge 2. Clinical data including anthropometric measures, thyroid function test, and hyperthyroidism symptom scale are recorded. RESULTS: Study enrollment began in December 2016, and the intervention and follow-up phases are ongoing. The results of the data analysis are expected to be available by September 2017. CONCLUSIONS: This study will provide a foundational feasibility trial of the clinical applications of biosignal measurements to the differential diagnosis, prediction of clinical course, early detection of recurrence, and treatment in patients with thyrotoxicosis. TRIAL REGISTRATION: ClinicalTrials.gov NCT03009357; https://clinicaltrials.gov/ct2/show/NCT03009357 (Archived by WebCite at http://www.webcitation.org/6wh4MWPm2) JMIR Publications 2018-02-21 /pmc/articles/PMC5842324/ /pubmed/29467121 http://dx.doi.org/10.2196/resprot.8119 Text en ©Jie-Eun Lee, Dong Hwa Lee, Tae Jung Oh, Kyoung Min Kim, Sung Hee Choi, Soo Lim, Young Joo Park, Do Joon Park, Hak Chul Jang, Jae Hoon Moon. Originally published in JMIR Research Protocols (http://www.researchprotocols.org), 21.02.2018. https://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work, first published in JMIR Research Protocols, is properly cited. The complete bibliographic information, a link to the original publication on http://www.researchprotocols.org, as well as this copyright and license information must be included.
spellingShingle Protocol
Lee, Jie-Eun
Lee, Dong Hwa
Oh, Tae Jung
Kim, Kyoung Min
Choi, Sung Hee
Lim, Soo
Park, Young Joo
Park, Do Joon
Jang, Hak Chul
Moon, Jae Hoon
Clinical Feasibility of Continuously Monitored Data for Heart Rate, Physical Activity, and Sleeping by Wearable Activity Trackers in Patients with Thyrotoxicosis: Protocol for a Prospective Longitudinal Observational Study
title Clinical Feasibility of Continuously Monitored Data for Heart Rate, Physical Activity, and Sleeping by Wearable Activity Trackers in Patients with Thyrotoxicosis: Protocol for a Prospective Longitudinal Observational Study
title_full Clinical Feasibility of Continuously Monitored Data for Heart Rate, Physical Activity, and Sleeping by Wearable Activity Trackers in Patients with Thyrotoxicosis: Protocol for a Prospective Longitudinal Observational Study
title_fullStr Clinical Feasibility of Continuously Monitored Data for Heart Rate, Physical Activity, and Sleeping by Wearable Activity Trackers in Patients with Thyrotoxicosis: Protocol for a Prospective Longitudinal Observational Study
title_full_unstemmed Clinical Feasibility of Continuously Monitored Data for Heart Rate, Physical Activity, and Sleeping by Wearable Activity Trackers in Patients with Thyrotoxicosis: Protocol for a Prospective Longitudinal Observational Study
title_short Clinical Feasibility of Continuously Monitored Data for Heart Rate, Physical Activity, and Sleeping by Wearable Activity Trackers in Patients with Thyrotoxicosis: Protocol for a Prospective Longitudinal Observational Study
title_sort clinical feasibility of continuously monitored data for heart rate, physical activity, and sleeping by wearable activity trackers in patients with thyrotoxicosis: protocol for a prospective longitudinal observational study
topic Protocol
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5842324/
https://www.ncbi.nlm.nih.gov/pubmed/29467121
http://dx.doi.org/10.2196/resprot.8119
work_keys_str_mv AT leejieeun clinicalfeasibilityofcontinuouslymonitoreddataforheartratephysicalactivityandsleepingbywearableactivitytrackersinpatientswiththyrotoxicosisprotocolforaprospectivelongitudinalobservationalstudy
AT leedonghwa clinicalfeasibilityofcontinuouslymonitoreddataforheartratephysicalactivityandsleepingbywearableactivitytrackersinpatientswiththyrotoxicosisprotocolforaprospectivelongitudinalobservationalstudy
AT ohtaejung clinicalfeasibilityofcontinuouslymonitoreddataforheartratephysicalactivityandsleepingbywearableactivitytrackersinpatientswiththyrotoxicosisprotocolforaprospectivelongitudinalobservationalstudy
AT kimkyoungmin clinicalfeasibilityofcontinuouslymonitoreddataforheartratephysicalactivityandsleepingbywearableactivitytrackersinpatientswiththyrotoxicosisprotocolforaprospectivelongitudinalobservationalstudy
AT choisunghee clinicalfeasibilityofcontinuouslymonitoreddataforheartratephysicalactivityandsleepingbywearableactivitytrackersinpatientswiththyrotoxicosisprotocolforaprospectivelongitudinalobservationalstudy
AT limsoo clinicalfeasibilityofcontinuouslymonitoreddataforheartratephysicalactivityandsleepingbywearableactivitytrackersinpatientswiththyrotoxicosisprotocolforaprospectivelongitudinalobservationalstudy
AT parkyoungjoo clinicalfeasibilityofcontinuouslymonitoreddataforheartratephysicalactivityandsleepingbywearableactivitytrackersinpatientswiththyrotoxicosisprotocolforaprospectivelongitudinalobservationalstudy
AT parkdojoon clinicalfeasibilityofcontinuouslymonitoreddataforheartratephysicalactivityandsleepingbywearableactivitytrackersinpatientswiththyrotoxicosisprotocolforaprospectivelongitudinalobservationalstudy
AT janghakchul clinicalfeasibilityofcontinuouslymonitoreddataforheartratephysicalactivityandsleepingbywearableactivitytrackersinpatientswiththyrotoxicosisprotocolforaprospectivelongitudinalobservationalstudy
AT moonjaehoon clinicalfeasibilityofcontinuouslymonitoreddataforheartratephysicalactivityandsleepingbywearableactivitytrackersinpatientswiththyrotoxicosisprotocolforaprospectivelongitudinalobservationalstudy