Cargando…

Early Results of the A.L.P.S. Proximal Humerus Locking Plate

BACKGROUND: Open reduction internal fixation of displaced 3 and 4-part proximal humerus fractures is an effective treatment modality particularly for the younger age group, but it is not without complications. Fixed angled locking screw plates are the mainstay of fixation. The A.L.P.S. Proximal Hume...

Descripción completa

Detalles Bibliográficos
Autores principales: Argyropoulos, Miltiadis, Kent, Matthew
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Bentham Open 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5842388/
https://www.ncbi.nlm.nih.gov/pubmed/29541270
http://dx.doi.org/10.2174/1874325001812010053
_version_ 1783304888760926208
author Argyropoulos, Miltiadis
Kent, Matthew
author_facet Argyropoulos, Miltiadis
Kent, Matthew
author_sort Argyropoulos, Miltiadis
collection PubMed
description BACKGROUND: Open reduction internal fixation of displaced 3 and 4-part proximal humerus fractures is an effective treatment modality particularly for the younger age group, but it is not without complications. Fixed angled locking screw plates are the mainstay of fixation. The A.L.P.S. Proximal Humerus Plating System is a new implant that has smooth locking pegs in the place of humeral head screws to help reduce glenoid damage in the event of cut-out and is designed to sit low on the humerus in order to reduce the risk of subacromial impingement. METHODS: Retrospective analysis of 15 consecutive patients who sustained closed displaced 3-part or 4-part fractures and had fixation surgery using the A.L.P.S. plate. Outcome measures were the time to radiographic and clinical union, Oxford Shoulder Score, quick DASH score and complications. RESULTS: Average follow-up was 31.9 weeks. Union was achieved in 100% of patients with a mean time to union of 15.1 weeks. In terms of function, mean OSS was 33.6 and mean quick DASH was 32.5. There were no instances of AVN. CONCLUSION: Our preliminary results of 15 patients followed up for a mean of 31.9 weeks show equitable union rates and time to union as well as functional scores compared to other available plating systems. This is the first study to report on this implant to date.
format Online
Article
Text
id pubmed-5842388
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Bentham Open
record_format MEDLINE/PubMed
spelling pubmed-58423882018-03-14 Early Results of the A.L.P.S. Proximal Humerus Locking Plate Argyropoulos, Miltiadis Kent, Matthew Open Orthop J Orthopaedics BACKGROUND: Open reduction internal fixation of displaced 3 and 4-part proximal humerus fractures is an effective treatment modality particularly for the younger age group, but it is not without complications. Fixed angled locking screw plates are the mainstay of fixation. The A.L.P.S. Proximal Humerus Plating System is a new implant that has smooth locking pegs in the place of humeral head screws to help reduce glenoid damage in the event of cut-out and is designed to sit low on the humerus in order to reduce the risk of subacromial impingement. METHODS: Retrospective analysis of 15 consecutive patients who sustained closed displaced 3-part or 4-part fractures and had fixation surgery using the A.L.P.S. plate. Outcome measures were the time to radiographic and clinical union, Oxford Shoulder Score, quick DASH score and complications. RESULTS: Average follow-up was 31.9 weeks. Union was achieved in 100% of patients with a mean time to union of 15.1 weeks. In terms of function, mean OSS was 33.6 and mean quick DASH was 32.5. There were no instances of AVN. CONCLUSION: Our preliminary results of 15 patients followed up for a mean of 31.9 weeks show equitable union rates and time to union as well as functional scores compared to other available plating systems. This is the first study to report on this implant to date. Bentham Open 2018-02-28 /pmc/articles/PMC5842388/ /pubmed/29541270 http://dx.doi.org/10.2174/1874325001812010053 Text en © 2018 Argyropoulos and Kent. https://creativecommons.org/licenses/by/4.0/legalcode This is an open access article distributed under the terms of the Creative Commons Attribution 4.0 International Public License (CC-BY 4.0), a copy of which is available at: https://creativecommons.org/licenses/by/4.0/legalcode. This license permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Orthopaedics
Argyropoulos, Miltiadis
Kent, Matthew
Early Results of the A.L.P.S. Proximal Humerus Locking Plate
title Early Results of the A.L.P.S. Proximal Humerus Locking Plate
title_full Early Results of the A.L.P.S. Proximal Humerus Locking Plate
title_fullStr Early Results of the A.L.P.S. Proximal Humerus Locking Plate
title_full_unstemmed Early Results of the A.L.P.S. Proximal Humerus Locking Plate
title_short Early Results of the A.L.P.S. Proximal Humerus Locking Plate
title_sort early results of the a.l.p.s. proximal humerus locking plate
topic Orthopaedics
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5842388/
https://www.ncbi.nlm.nih.gov/pubmed/29541270
http://dx.doi.org/10.2174/1874325001812010053
work_keys_str_mv AT argyropoulosmiltiadis earlyresultsofthealpsproximalhumeruslockingplate
AT kentmatthew earlyresultsofthealpsproximalhumeruslockingplate