Cargando…
A digital assessment system for evaluating kinetic tremor in essential tremor and Parkinson’s disease
BACKGROUND: Spiral drawing on papers is a common tremor evaluation tool for diagnosing patients with essential tremor (ET) or Parkinson’s disease (PD). No standard drawing methods and parameters that use graphic tablets are yet available for objective evaluation. METHODS: This study established a tr...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5845296/ https://www.ncbi.nlm.nih.gov/pubmed/29523097 http://dx.doi.org/10.1186/s12883-018-1027-2 |
_version_ | 1783305399863083008 |
---|---|
author | Lin, Po-Chieh Chen, Kai-Hsiang Yang, Bing-Shiang Chen, Yu-Jung |
author_facet | Lin, Po-Chieh Chen, Kai-Hsiang Yang, Bing-Shiang Chen, Yu-Jung |
author_sort | Lin, Po-Chieh |
collection | PubMed |
description | BACKGROUND: Spiral drawing on papers is a common tremor evaluation tool for diagnosing patients with essential tremor (ET) or Parkinson’s disease (PD). No standard drawing methods and parameters that use graphic tablets are yet available for objective evaluation. METHODS: This study established a tremor assessment system for tremor severity by using graphic tablets. Twelve patients with ET and twelve patients with PD were tested to establish system algorithms, and six additional patients were tested with the developed system to evaluate its performance. The patients also performed spiral drawing with three guiding paradigms on a graphic tablet: traced along a given spiral (S1), performed freehand drawing (S2), and traced along a guiding point (S3). Three parameters were calculated to quantify tremor severity: the means of radial difference per radian (|dr/dθ|), the means of radial difference per second (|dr/dt|), and the area under curve (AUC) of the frequency spectrum of the velocity. Each patient’s drawing was also evaluated using a visual rating scale (VRS) by experienced physicians. The interrater reliability was examined to identify the most consistent test paradigm. RESULTS: The parameter |dr/dθ| and AUC correlated well with the VRS (R > 0.8) in S1, S2 and S3 tests. The S1 test presented the best interrater reliability (Weighted Kappa coefficient, k = 0.80) among three tests. The Weighted Kappa coefficients are 0.67 and 0.71 in S2 and S3 tests, respectively. CONCLUSIONS: We developed three different guiding paradigms for spiral drawing on a digital graphic tablet for clinical tests. Three parameters were calculated to represent the tremor severity in spiral drawing and used to quantify temporal and spatial characteristics of tremor, and provided good correlation with current clinical assessments. The test “traced along a given spiral” is recommended due to its good interrater reliability. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1186/s12883-018-1027-2) contains supplementary material, which is available to authorized users. |
format | Online Article Text |
id | pubmed-5845296 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-58452962018-03-19 A digital assessment system for evaluating kinetic tremor in essential tremor and Parkinson’s disease Lin, Po-Chieh Chen, Kai-Hsiang Yang, Bing-Shiang Chen, Yu-Jung BMC Neurol Research Article BACKGROUND: Spiral drawing on papers is a common tremor evaluation tool for diagnosing patients with essential tremor (ET) or Parkinson’s disease (PD). No standard drawing methods and parameters that use graphic tablets are yet available for objective evaluation. METHODS: This study established a tremor assessment system for tremor severity by using graphic tablets. Twelve patients with ET and twelve patients with PD were tested to establish system algorithms, and six additional patients were tested with the developed system to evaluate its performance. The patients also performed spiral drawing with three guiding paradigms on a graphic tablet: traced along a given spiral (S1), performed freehand drawing (S2), and traced along a guiding point (S3). Three parameters were calculated to quantify tremor severity: the means of radial difference per radian (|dr/dθ|), the means of radial difference per second (|dr/dt|), and the area under curve (AUC) of the frequency spectrum of the velocity. Each patient’s drawing was also evaluated using a visual rating scale (VRS) by experienced physicians. The interrater reliability was examined to identify the most consistent test paradigm. RESULTS: The parameter |dr/dθ| and AUC correlated well with the VRS (R > 0.8) in S1, S2 and S3 tests. The S1 test presented the best interrater reliability (Weighted Kappa coefficient, k = 0.80) among three tests. The Weighted Kappa coefficients are 0.67 and 0.71 in S2 and S3 tests, respectively. CONCLUSIONS: We developed three different guiding paradigms for spiral drawing on a digital graphic tablet for clinical tests. Three parameters were calculated to represent the tremor severity in spiral drawing and used to quantify temporal and spatial characteristics of tremor, and provided good correlation with current clinical assessments. The test “traced along a given spiral” is recommended due to its good interrater reliability. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1186/s12883-018-1027-2) contains supplementary material, which is available to authorized users. BioMed Central 2018-03-09 /pmc/articles/PMC5845296/ /pubmed/29523097 http://dx.doi.org/10.1186/s12883-018-1027-2 Text en © The Author(s). 2018 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. |
spellingShingle | Research Article Lin, Po-Chieh Chen, Kai-Hsiang Yang, Bing-Shiang Chen, Yu-Jung A digital assessment system for evaluating kinetic tremor in essential tremor and Parkinson’s disease |
title | A digital assessment system for evaluating kinetic tremor in essential tremor and Parkinson’s disease |
title_full | A digital assessment system for evaluating kinetic tremor in essential tremor and Parkinson’s disease |
title_fullStr | A digital assessment system for evaluating kinetic tremor in essential tremor and Parkinson’s disease |
title_full_unstemmed | A digital assessment system for evaluating kinetic tremor in essential tremor and Parkinson’s disease |
title_short | A digital assessment system for evaluating kinetic tremor in essential tremor and Parkinson’s disease |
title_sort | digital assessment system for evaluating kinetic tremor in essential tremor and parkinson’s disease |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5845296/ https://www.ncbi.nlm.nih.gov/pubmed/29523097 http://dx.doi.org/10.1186/s12883-018-1027-2 |
work_keys_str_mv | AT linpochieh adigitalassessmentsystemforevaluatingkinetictremorinessentialtremorandparkinsonsdisease AT chenkaihsiang adigitalassessmentsystemforevaluatingkinetictremorinessentialtremorandparkinsonsdisease AT yangbingshiang adigitalassessmentsystemforevaluatingkinetictremorinessentialtremorandparkinsonsdisease AT chenyujung adigitalassessmentsystemforevaluatingkinetictremorinessentialtremorandparkinsonsdisease AT linpochieh digitalassessmentsystemforevaluatingkinetictremorinessentialtremorandparkinsonsdisease AT chenkaihsiang digitalassessmentsystemforevaluatingkinetictremorinessentialtremorandparkinsonsdisease AT yangbingshiang digitalassessmentsystemforevaluatingkinetictremorinessentialtremorandparkinsonsdisease AT chenyujung digitalassessmentsystemforevaluatingkinetictremorinessentialtremorandparkinsonsdisease |