Does the air condition system in busses spread allergic fungi into driver space?
The aim of this study was to establish whether the air-conditioning system in buses constitutes an additional source of indoor air contamination with fungi, and whether or not the fungi concentration depends on the period from the last disinfection of the system, combined with replacement of the cab...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Berlin Heidelberg
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5846988/ https://www.ncbi.nlm.nih.gov/pubmed/29209965 http://dx.doi.org/10.1007/s11356-017-0830-4 |
_version_ | 1783305666730917888 |
---|---|
author | Sowiak, Małgorzata Kozajda, Anna Jeżak, Karolina Szadkowska-Stańczyk, Irena |
author_facet | Sowiak, Małgorzata Kozajda, Anna Jeżak, Karolina Szadkowska-Stańczyk, Irena |
author_sort | Sowiak, Małgorzata |
collection | PubMed |
description | The aim of this study was to establish whether the air-conditioning system in buses constitutes an additional source of indoor air contamination with fungi, and whether or not the fungi concentration depends on the period from the last disinfection of the system, combined with replacement of the cabin dust particle filter. The air samples to fungi analysis using impact method were taken in 30 buses (20 with an air-conditioning system, ACS; 10 with a ventilation system, VS) in two series: 1 and 22 weeks after cabin filter replacement and disinfection of the air-conditioning system. During one test in each bus were taken two samples: before the air-conditioning or ventilation system switched on and 6 min after operating of these systems. The atmospheric air was the external background (EB). After 1 week of use of the system, the fungi concentrations before starting of the ACS and VS system were 527.8 and 1053.0 cfu/m(3), respectively, and after 22 weeks the concentrations were 351.9 and 1069.6 cfu/m(3), respectively. While in the sample after 6 min of ACS and VS system operating, the fungi concentration after 1 week of use was 127.6 and 233.7 cfu/m(3), respectively, and after 22 weeks it was 113.3 and 324.9 cfu/m(3), respectively. Results do not provide strong evidence that air-conditioning system is an additional source of indoor air contamination with fungi. A longer operation of the system promoted increase of fungi concentration in air-conditioned buses only. |
format | Online Article Text |
id | pubmed-5846988 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | Springer Berlin Heidelberg |
record_format | MEDLINE/PubMed |
spelling | pubmed-58469882018-03-20 Does the air condition system in busses spread allergic fungi into driver space? Sowiak, Małgorzata Kozajda, Anna Jeżak, Karolina Szadkowska-Stańczyk, Irena Environ Sci Pollut Res Int Research Article The aim of this study was to establish whether the air-conditioning system in buses constitutes an additional source of indoor air contamination with fungi, and whether or not the fungi concentration depends on the period from the last disinfection of the system, combined with replacement of the cabin dust particle filter. The air samples to fungi analysis using impact method were taken in 30 buses (20 with an air-conditioning system, ACS; 10 with a ventilation system, VS) in two series: 1 and 22 weeks after cabin filter replacement and disinfection of the air-conditioning system. During one test in each bus were taken two samples: before the air-conditioning or ventilation system switched on and 6 min after operating of these systems. The atmospheric air was the external background (EB). After 1 week of use of the system, the fungi concentrations before starting of the ACS and VS system were 527.8 and 1053.0 cfu/m(3), respectively, and after 22 weeks the concentrations were 351.9 and 1069.6 cfu/m(3), respectively. While in the sample after 6 min of ACS and VS system operating, the fungi concentration after 1 week of use was 127.6 and 233.7 cfu/m(3), respectively, and after 22 weeks it was 113.3 and 324.9 cfu/m(3), respectively. Results do not provide strong evidence that air-conditioning system is an additional source of indoor air contamination with fungi. A longer operation of the system promoted increase of fungi concentration in air-conditioned buses only. Springer Berlin Heidelberg 2017-12-05 2018 /pmc/articles/PMC5846988/ /pubmed/29209965 http://dx.doi.org/10.1007/s11356-017-0830-4 Text en © The Author(s) 2017 Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. |
spellingShingle | Research Article Sowiak, Małgorzata Kozajda, Anna Jeżak, Karolina Szadkowska-Stańczyk, Irena Does the air condition system in busses spread allergic fungi into driver space? |
title | Does the air condition system in busses spread allergic fungi into driver space? |
title_full | Does the air condition system in busses spread allergic fungi into driver space? |
title_fullStr | Does the air condition system in busses spread allergic fungi into driver space? |
title_full_unstemmed | Does the air condition system in busses spread allergic fungi into driver space? |
title_short | Does the air condition system in busses spread allergic fungi into driver space? |
title_sort | does the air condition system in busses spread allergic fungi into driver space? |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5846988/ https://www.ncbi.nlm.nih.gov/pubmed/29209965 http://dx.doi.org/10.1007/s11356-017-0830-4 |
work_keys_str_mv | AT sowiakmałgorzata doestheairconditionsysteminbussesspreadallergicfungiintodriverspace AT kozajdaanna doestheairconditionsysteminbussesspreadallergicfungiintodriverspace AT jezakkarolina doestheairconditionsysteminbussesspreadallergicfungiintodriverspace AT szadkowskastanczykirena doestheairconditionsysteminbussesspreadallergicfungiintodriverspace |