Cargando…

Rupture du long extenseur du pouce secondaire à une fracture du radius distal réparée par une greffe tendineuse partielle à partir du long extenseur radial du carpe avec un bon résultat fonctionnel

We report the case of a 36-year old female patient injured in a fall from a horse. Radiological assessment showed closed comminuted fracture of the lower extremity of the left radius with extensive displacement (A & B). Initial management was based on open osteosynthesis with screwed anterior pl...

Descripción completa

Detalles Bibliográficos
Autores principales: Nkaoui, Mustafa, Yazidi, Amine El
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The African Field Epidemiology Network 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5847133/
https://www.ncbi.nlm.nih.gov/pubmed/29541299
http://dx.doi.org/10.11604/pamj.2017.28.152.12362
_version_ 1783305691851653120
author Nkaoui, Mustafa
Yazidi, Amine El
author_facet Nkaoui, Mustafa
Yazidi, Amine El
author_sort Nkaoui, Mustafa
collection PubMed
description We report the case of a 36-year old female patient injured in a fall from a horse. Radiological assessment showed closed comminuted fracture of the lower extremity of the left radius with extensive displacement (A & B). Initial management was based on open osteosynthesis with screwed anterior plate and nails (C) followed by functional rehabilitation. Patient's evolution was marked by the occurrence of secondary fracture of the extensor longus, clinically objectified by thumb extension deficit and confirmed by dynamic Ultrasound (D). The patient underwent surgery with exploration of the frayed tendon caught in a voluminous bony callus (E). Conservative treatment was not possible, repair was based on resection and partial graft from the extensor carpi radialis longus after dissection via the same approach. Outcome after rehabilitation was excellent (F) with gradual resumption of work from the second month.
format Online
Article
Text
id pubmed-5847133
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher The African Field Epidemiology Network
record_format MEDLINE/PubMed
spelling pubmed-58471332018-03-14 Rupture du long extenseur du pouce secondaire à une fracture du radius distal réparée par une greffe tendineuse partielle à partir du long extenseur radial du carpe avec un bon résultat fonctionnel Nkaoui, Mustafa Yazidi, Amine El Pan Afr Med J Images in Medicine We report the case of a 36-year old female patient injured in a fall from a horse. Radiological assessment showed closed comminuted fracture of the lower extremity of the left radius with extensive displacement (A & B). Initial management was based on open osteosynthesis with screwed anterior plate and nails (C) followed by functional rehabilitation. Patient's evolution was marked by the occurrence of secondary fracture of the extensor longus, clinically objectified by thumb extension deficit and confirmed by dynamic Ultrasound (D). The patient underwent surgery with exploration of the frayed tendon caught in a voluminous bony callus (E). Conservative treatment was not possible, repair was based on resection and partial graft from the extensor carpi radialis longus after dissection via the same approach. Outcome after rehabilitation was excellent (F) with gradual resumption of work from the second month. The African Field Epidemiology Network 2017-10-18 /pmc/articles/PMC5847133/ /pubmed/29541299 http://dx.doi.org/10.11604/pamj.2017.28.152.12362 Text en © Mustafa Nkaoui et al. http://creativecommons.org/licenses/by/2.0/ The Pan African Medical Journal - ISSN 1937-8688. This is an Open Access article distributed under the terms of the Creative Commons Attribution License which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Images in Medicine
Nkaoui, Mustafa
Yazidi, Amine El
Rupture du long extenseur du pouce secondaire à une fracture du radius distal réparée par une greffe tendineuse partielle à partir du long extenseur radial du carpe avec un bon résultat fonctionnel
title Rupture du long extenseur du pouce secondaire à une fracture du radius distal réparée par une greffe tendineuse partielle à partir du long extenseur radial du carpe avec un bon résultat fonctionnel
title_full Rupture du long extenseur du pouce secondaire à une fracture du radius distal réparée par une greffe tendineuse partielle à partir du long extenseur radial du carpe avec un bon résultat fonctionnel
title_fullStr Rupture du long extenseur du pouce secondaire à une fracture du radius distal réparée par une greffe tendineuse partielle à partir du long extenseur radial du carpe avec un bon résultat fonctionnel
title_full_unstemmed Rupture du long extenseur du pouce secondaire à une fracture du radius distal réparée par une greffe tendineuse partielle à partir du long extenseur radial du carpe avec un bon résultat fonctionnel
title_short Rupture du long extenseur du pouce secondaire à une fracture du radius distal réparée par une greffe tendineuse partielle à partir du long extenseur radial du carpe avec un bon résultat fonctionnel
title_sort rupture du long extenseur du pouce secondaire à une fracture du radius distal réparée par une greffe tendineuse partielle à partir du long extenseur radial du carpe avec un bon résultat fonctionnel
topic Images in Medicine
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5847133/
https://www.ncbi.nlm.nih.gov/pubmed/29541299
http://dx.doi.org/10.11604/pamj.2017.28.152.12362
work_keys_str_mv AT nkaouimustafa rupturedulongextenseurdupoucesecondaireaunefractureduradiusdistalrepareeparunegreffetendineusepartielleapartirdulongextenseurradialducarpeavecunbonresultatfonctionnel
AT yazidiamineel rupturedulongextenseurdupoucesecondaireaunefractureduradiusdistalrepareeparunegreffetendineusepartielleapartirdulongextenseurradialducarpeavecunbonresultatfonctionnel