Characteristics of Astigmatism after MyoRing Implantation
Considering the rising number of MyoRing implantation procedures in keratoconic corneas and the refractive outcomes associated with this treatment modality, this study aimed to evaluate and compare the magnitude and axis orientation of total and corneal astigmatism between before and after MyoRing i...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Medical Hypothesis, Discovery & Innovation Ophthalmology
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5847308/ https://www.ncbi.nlm.nih.gov/pubmed/29560367 |
_version_ | 1783305725301227520 |
---|---|
author | KHOSRAVI, Bahram KHORRAMI-NEJAD, Masoud RAJABI, Sattar AMIRI, Mohamad HASHEMIAN, Hesam KHODAPARAST, Mehdi |
author_facet | KHOSRAVI, Bahram KHORRAMI-NEJAD, Masoud RAJABI, Sattar AMIRI, Mohamad HASHEMIAN, Hesam KHODAPARAST, Mehdi |
author_sort | KHOSRAVI, Bahram |
collection | PubMed |
description | Considering the rising number of MyoRing implantation procedures in keratoconic corneas and the refractive outcomes associated with this treatment modality, this study aimed to evaluate and compare the magnitude and axis orientation of total and corneal astigmatism between before and after MyoRing implantation in 34 eyes of 28 patients with keratoconus (KCN) (mean age: 29.41 ± 7.0 years). The inclusion criterion was a reliable diagnosis of clinical KCN based on corneal biomicroscopic and tomographic findings. The mean total astigmatism of ocular refraction decreased significantly from -4.27 ± 3.15 D (before MyoRing implantation) to -2.18 ± 1.63 D (after MyoRing implantation) (P < 0.001). The mean astigmatism in the anterior and posterior surface of the cornea decreased significantly by 1.16 D (P = 0.001) and 0.24 D (P = 0.009), respectively, after MyoRing implantation. Before MyoRing implantation, the axis orientation of total ocular astigmatism for with-the-rule, oblique, and against-the-rule astigmatism was 21%, 42%, and 37%, respectively; at 6 months after MyoRing implantation, it was 18%, 24%, and 58%, respectively. Before MyoRing implantation, the axis orientation for with-the-rule, against-the-rule, and oblique astigmatism of the anterior surface of the cornea was 59%, 24%, and 17%, respectively; at 6 months after MyoRing implantation, it was 52%, 24%, and 24%, respectively. Before MyoRing implantation, the axis orientation of with-the-rule, oblique, and against-the-rule astigmatism of the posterior surface of the cornea was 68%, 29%, and 3%, respectively; at 6 months after MyoRing implantation, it was 67%, 12%, and 12%, respectively. MyoRing implantation significantly decreased the amount of total, anterior, and posterior corneal astigmatism. |
format | Online Article Text |
id | pubmed-5847308 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | Medical Hypothesis, Discovery & Innovation Ophthalmology |
record_format | MEDLINE/PubMed |
spelling | pubmed-58473082018-03-20 Characteristics of Astigmatism after MyoRing Implantation KHOSRAVI, Bahram KHORRAMI-NEJAD, Masoud RAJABI, Sattar AMIRI, Mohamad HASHEMIAN, Hesam KHODAPARAST, Mehdi Med Hypothesis Discov Innov Ophthalmol Original Article Considering the rising number of MyoRing implantation procedures in keratoconic corneas and the refractive outcomes associated with this treatment modality, this study aimed to evaluate and compare the magnitude and axis orientation of total and corneal astigmatism between before and after MyoRing implantation in 34 eyes of 28 patients with keratoconus (KCN) (mean age: 29.41 ± 7.0 years). The inclusion criterion was a reliable diagnosis of clinical KCN based on corneal biomicroscopic and tomographic findings. The mean total astigmatism of ocular refraction decreased significantly from -4.27 ± 3.15 D (before MyoRing implantation) to -2.18 ± 1.63 D (after MyoRing implantation) (P < 0.001). The mean astigmatism in the anterior and posterior surface of the cornea decreased significantly by 1.16 D (P = 0.001) and 0.24 D (P = 0.009), respectively, after MyoRing implantation. Before MyoRing implantation, the axis orientation of total ocular astigmatism for with-the-rule, oblique, and against-the-rule astigmatism was 21%, 42%, and 37%, respectively; at 6 months after MyoRing implantation, it was 18%, 24%, and 58%, respectively. Before MyoRing implantation, the axis orientation for with-the-rule, against-the-rule, and oblique astigmatism of the anterior surface of the cornea was 59%, 24%, and 17%, respectively; at 6 months after MyoRing implantation, it was 52%, 24%, and 24%, respectively. Before MyoRing implantation, the axis orientation of with-the-rule, oblique, and against-the-rule astigmatism of the posterior surface of the cornea was 68%, 29%, and 3%, respectively; at 6 months after MyoRing implantation, it was 67%, 12%, and 12%, respectively. MyoRing implantation significantly decreased the amount of total, anterior, and posterior corneal astigmatism. Medical Hypothesis, Discovery & Innovation Ophthalmology 2017 /pmc/articles/PMC5847308/ /pubmed/29560367 Text en © 2017, Med Hypothesis Discov Innov Ophthalmol. This is an open-access article distributed under the terms of the Creative Commons Attribution Non-Commercial 3.0 License (CC BY-NC 3.0), (https://creativecommons.org/licenses/by-nc/3.0/) which allows users to read, copy, distribute and make derivative works for non-commercial purposes from the material, as long as the author of the original work is cited properly. |
spellingShingle | Original Article KHOSRAVI, Bahram KHORRAMI-NEJAD, Masoud RAJABI, Sattar AMIRI, Mohamad HASHEMIAN, Hesam KHODAPARAST, Mehdi Characteristics of Astigmatism after MyoRing Implantation |
title | Characteristics of Astigmatism after MyoRing Implantation |
title_full | Characteristics of Astigmatism after MyoRing Implantation |
title_fullStr | Characteristics of Astigmatism after MyoRing Implantation |
title_full_unstemmed | Characteristics of Astigmatism after MyoRing Implantation |
title_short | Characteristics of Astigmatism after MyoRing Implantation |
title_sort | characteristics of astigmatism after myoring implantation |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5847308/ https://www.ncbi.nlm.nih.gov/pubmed/29560367 |
work_keys_str_mv | AT khosravibahram characteristicsofastigmatismaftermyoringimplantation AT khorraminejadmasoud characteristicsofastigmatismaftermyoringimplantation AT rajabisattar characteristicsofastigmatismaftermyoringimplantation AT amirimohamad characteristicsofastigmatismaftermyoringimplantation AT hashemianhesam characteristicsofastigmatismaftermyoringimplantation AT khodaparastmehdi characteristicsofastigmatismaftermyoringimplantation |