Cargando…

Data on two- and three-dimensional optical coherence tomography guidance for the treatment for the bifurcation lesion

This article comprised the data related to the research article entitled “Feasibility and usefulness of three-dimensional optical coherence tomography guidance for optimal side branch treatment in coronary bifurcation stenting” (Nagoshi et al., In press) [1]. In this article we reports details about...

Descripción completa

Detalles Bibliográficos
Autores principales: Nagoshi, Ryoji, Okamura, Takayuki, Murasato, Yoshinobu, Fujimura, Tatsuhiro, Yamawaki, Masahiro, Ono, Shiro, Serikawa, Takeshi, Hikichi, Yutaka, Nakao, Fumiaki, Sakamoto, Tomohiro, Shinke, Toshiro, Kijima, Yoichi, Kozuki, Amane, Shibata, Hiroyuki, Shite, Junya
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5847640/
https://www.ncbi.nlm.nih.gov/pubmed/29541673
http://dx.doi.org/10.1016/j.dib.2017.12.024
_version_ 1783305766714736640
author Nagoshi, Ryoji
Okamura, Takayuki
Murasato, Yoshinobu
Fujimura, Tatsuhiro
Yamawaki, Masahiro
Ono, Shiro
Serikawa, Takeshi
Hikichi, Yutaka
Nakao, Fumiaki
Sakamoto, Tomohiro
Shinke, Toshiro
Kijima, Yoichi
Kozuki, Amane
Shibata, Hiroyuki
Shite, Junya
author_facet Nagoshi, Ryoji
Okamura, Takayuki
Murasato, Yoshinobu
Fujimura, Tatsuhiro
Yamawaki, Masahiro
Ono, Shiro
Serikawa, Takeshi
Hikichi, Yutaka
Nakao, Fumiaki
Sakamoto, Tomohiro
Shinke, Toshiro
Kijima, Yoichi
Kozuki, Amane
Shibata, Hiroyuki
Shite, Junya
author_sort Nagoshi, Ryoji
collection PubMed
description This article comprised the data related to the research article entitled “Feasibility and usefulness of three-dimensional optical coherence tomography guidance for optimal side branch treatment in coronary bifurcation stenting” (Nagoshi et al., In press) [1]. In this article we reports details about two patterns of guide wire (GW) recrossing position after crossover stenting in bifurcation lesion classified with three-dimensional optical coherence tomography (3D-OCT) (Okamura et al., 2014) [2] and follow-up data about the treatment with percutaneous coronary intervention(PCI) for bifurcation lesion in terms of the two- (2D) or 3D-OCT guidance. Subgroup analysis about differences in the parameters between the proximal and the distal GW recrossing patterns are analyzed here.
format Online
Article
Text
id pubmed-5847640
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-58476402018-03-14 Data on two- and three-dimensional optical coherence tomography guidance for the treatment for the bifurcation lesion Nagoshi, Ryoji Okamura, Takayuki Murasato, Yoshinobu Fujimura, Tatsuhiro Yamawaki, Masahiro Ono, Shiro Serikawa, Takeshi Hikichi, Yutaka Nakao, Fumiaki Sakamoto, Tomohiro Shinke, Toshiro Kijima, Yoichi Kozuki, Amane Shibata, Hiroyuki Shite, Junya Data Brief Medicine and Dentistry This article comprised the data related to the research article entitled “Feasibility and usefulness of three-dimensional optical coherence tomography guidance for optimal side branch treatment in coronary bifurcation stenting” (Nagoshi et al., In press) [1]. In this article we reports details about two patterns of guide wire (GW) recrossing position after crossover stenting in bifurcation lesion classified with three-dimensional optical coherence tomography (3D-OCT) (Okamura et al., 2014) [2] and follow-up data about the treatment with percutaneous coronary intervention(PCI) for bifurcation lesion in terms of the two- (2D) or 3D-OCT guidance. Subgroup analysis about differences in the parameters between the proximal and the distal GW recrossing patterns are analyzed here. Elsevier 2017-12-14 /pmc/articles/PMC5847640/ /pubmed/29541673 http://dx.doi.org/10.1016/j.dib.2017.12.024 Text en © 2018 The Authors http://creativecommons.org/licenses/by/4.0/ This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Medicine and Dentistry
Nagoshi, Ryoji
Okamura, Takayuki
Murasato, Yoshinobu
Fujimura, Tatsuhiro
Yamawaki, Masahiro
Ono, Shiro
Serikawa, Takeshi
Hikichi, Yutaka
Nakao, Fumiaki
Sakamoto, Tomohiro
Shinke, Toshiro
Kijima, Yoichi
Kozuki, Amane
Shibata, Hiroyuki
Shite, Junya
Data on two- and three-dimensional optical coherence tomography guidance for the treatment for the bifurcation lesion
title Data on two- and three-dimensional optical coherence tomography guidance for the treatment for the bifurcation lesion
title_full Data on two- and three-dimensional optical coherence tomography guidance for the treatment for the bifurcation lesion
title_fullStr Data on two- and three-dimensional optical coherence tomography guidance for the treatment for the bifurcation lesion
title_full_unstemmed Data on two- and three-dimensional optical coherence tomography guidance for the treatment for the bifurcation lesion
title_short Data on two- and three-dimensional optical coherence tomography guidance for the treatment for the bifurcation lesion
title_sort data on two- and three-dimensional optical coherence tomography guidance for the treatment for the bifurcation lesion
topic Medicine and Dentistry
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5847640/
https://www.ncbi.nlm.nih.gov/pubmed/29541673
http://dx.doi.org/10.1016/j.dib.2017.12.024
work_keys_str_mv AT nagoshiryoji dataontwoandthreedimensionalopticalcoherencetomographyguidanceforthetreatmentforthebifurcationlesion
AT okamuratakayuki dataontwoandthreedimensionalopticalcoherencetomographyguidanceforthetreatmentforthebifurcationlesion
AT murasatoyoshinobu dataontwoandthreedimensionalopticalcoherencetomographyguidanceforthetreatmentforthebifurcationlesion
AT fujimuratatsuhiro dataontwoandthreedimensionalopticalcoherencetomographyguidanceforthetreatmentforthebifurcationlesion
AT yamawakimasahiro dataontwoandthreedimensionalopticalcoherencetomographyguidanceforthetreatmentforthebifurcationlesion
AT onoshiro dataontwoandthreedimensionalopticalcoherencetomographyguidanceforthetreatmentforthebifurcationlesion
AT serikawatakeshi dataontwoandthreedimensionalopticalcoherencetomographyguidanceforthetreatmentforthebifurcationlesion
AT hikichiyutaka dataontwoandthreedimensionalopticalcoherencetomographyguidanceforthetreatmentforthebifurcationlesion
AT nakaofumiaki dataontwoandthreedimensionalopticalcoherencetomographyguidanceforthetreatmentforthebifurcationlesion
AT sakamototomohiro dataontwoandthreedimensionalopticalcoherencetomographyguidanceforthetreatmentforthebifurcationlesion
AT shinketoshiro dataontwoandthreedimensionalopticalcoherencetomographyguidanceforthetreatmentforthebifurcationlesion
AT kijimayoichi dataontwoandthreedimensionalopticalcoherencetomographyguidanceforthetreatmentforthebifurcationlesion
AT kozukiamane dataontwoandthreedimensionalopticalcoherencetomographyguidanceforthetreatmentforthebifurcationlesion
AT shibatahiroyuki dataontwoandthreedimensionalopticalcoherencetomographyguidanceforthetreatmentforthebifurcationlesion
AT shitejunya dataontwoandthreedimensionalopticalcoherencetomographyguidanceforthetreatmentforthebifurcationlesion