Cargando…

Accuracy and Safety of the Cytosponge for Assessing Histologic Activity in Eosinophilic Esophagitis: A Two-Center Study

OBJECTIVES: Management of eosinophilic esophagitis (EoE) requires repeated endoscopic mucosal sampling to assess disease activity. A less invasive and expensive means of monitoring of EoE is required. The objective of this study was to assess the accuracy, safety, and tolerability of the cytosponge...

Descripción completa

Detalles Bibliográficos
Autores principales: Katzka, David A, Smyrk, Thomas C, Alexander, Jeffrey A, Geno, Debra M, Beitia, RoseMary A, Chang, Audrey O, Shaheen, Nicholas J, Fitzgerald, Rebecca C, Dellon, Evan S
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5848207/
https://www.ncbi.nlm.nih.gov/pubmed/28809387
http://dx.doi.org/10.1038/ajg.2017.244
_version_ 1783305845043363840
author Katzka, David A
Smyrk, Thomas C
Alexander, Jeffrey A
Geno, Debra M
Beitia, RoseMary A
Chang, Audrey O
Shaheen, Nicholas J
Fitzgerald, Rebecca C
Dellon, Evan S
author_facet Katzka, David A
Smyrk, Thomas C
Alexander, Jeffrey A
Geno, Debra M
Beitia, RoseMary A
Chang, Audrey O
Shaheen, Nicholas J
Fitzgerald, Rebecca C
Dellon, Evan S
author_sort Katzka, David A
collection PubMed
description OBJECTIVES: Management of eosinophilic esophagitis (EoE) requires repeated endoscopic mucosal sampling to assess disease activity. A less invasive and expensive means of monitoring of EoE is required. The objective of this study was to assess the accuracy, safety, and tolerability of the cytosponge compared to endoscopy and biopsy for histologic assessment of EoE. METHODS: In this prospective two-center cross-sectional study, patients with known EoE underwent cytosponge sampling followed by endoscopy and biopsy. Sample adequacy and eosinophil counts (eos/HPF) were determined for both cytosponge and endoscopic samples. The cytosponge was assessed for diagnostic accuracy, safety, and patient preference as compared to endoscopy. RESULTS: Six patients (7%) failed to swallow the sponge. One hundred and five procedures were successfully performed in 80 patients (66% male, 100% white, 19% stricture). The cytosponge sample was adequate in 102 and the biopsy in 104; 101 procedures had adequate samples by both techniques. Fifty-seven biopsies were graded as active EoE with ≥15 eos/HPF as the gold standard. Eosinophil counts highly correlated between the biopsy and cytosponge (r=0.78, P<0.0001). Using a cutoff of ≤15 eos/HPF for inactive disease, the sensitivity and specificity of the cytosponge was 75% and 86%, respectively. Six patients had active EoE on cytosponge not found on biopsy. For biopsies with inactive EoE, the cytosponge identified 38/44. No complications occurred, and cytosponge endoscopic abrasion scores were low (0.34/4). Patients preferred cytosponge to endoscopy with higher rating scores (7.27 vs. 6.11, P=0.002). CONCLUSIONS: Compared to endoscopy with biopsy, cytosponge provided a minimally invasive, safe, well tolerated, and accurate method to assess EoE histologic activity. (ClinicalTrial.gov number NCT01585103).
format Online
Article
Text
id pubmed-5848207
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Nature Publishing Group
record_format MEDLINE/PubMed
spelling pubmed-58482072018-03-15 Accuracy and Safety of the Cytosponge for Assessing Histologic Activity in Eosinophilic Esophagitis: A Two-Center Study Katzka, David A Smyrk, Thomas C Alexander, Jeffrey A Geno, Debra M Beitia, RoseMary A Chang, Audrey O Shaheen, Nicholas J Fitzgerald, Rebecca C Dellon, Evan S Am J Gastroenterol Esophagus OBJECTIVES: Management of eosinophilic esophagitis (EoE) requires repeated endoscopic mucosal sampling to assess disease activity. A less invasive and expensive means of monitoring of EoE is required. The objective of this study was to assess the accuracy, safety, and tolerability of the cytosponge compared to endoscopy and biopsy for histologic assessment of EoE. METHODS: In this prospective two-center cross-sectional study, patients with known EoE underwent cytosponge sampling followed by endoscopy and biopsy. Sample adequacy and eosinophil counts (eos/HPF) were determined for both cytosponge and endoscopic samples. The cytosponge was assessed for diagnostic accuracy, safety, and patient preference as compared to endoscopy. RESULTS: Six patients (7%) failed to swallow the sponge. One hundred and five procedures were successfully performed in 80 patients (66% male, 100% white, 19% stricture). The cytosponge sample was adequate in 102 and the biopsy in 104; 101 procedures had adequate samples by both techniques. Fifty-seven biopsies were graded as active EoE with ≥15 eos/HPF as the gold standard. Eosinophil counts highly correlated between the biopsy and cytosponge (r=0.78, P<0.0001). Using a cutoff of ≤15 eos/HPF for inactive disease, the sensitivity and specificity of the cytosponge was 75% and 86%, respectively. Six patients had active EoE on cytosponge not found on biopsy. For biopsies with inactive EoE, the cytosponge identified 38/44. No complications occurred, and cytosponge endoscopic abrasion scores were low (0.34/4). Patients preferred cytosponge to endoscopy with higher rating scores (7.27 vs. 6.11, P=0.002). CONCLUSIONS: Compared to endoscopy with biopsy, cytosponge provided a minimally invasive, safe, well tolerated, and accurate method to assess EoE histologic activity. (ClinicalTrial.gov number NCT01585103). Nature Publishing Group 2017 2017-08-15 /pmc/articles/PMC5848207/ /pubmed/28809387 http://dx.doi.org/10.1038/ajg.2017.244 Text en Copyright © 2017 American College of Gastroenterology
spellingShingle Esophagus
Katzka, David A
Smyrk, Thomas C
Alexander, Jeffrey A
Geno, Debra M
Beitia, RoseMary A
Chang, Audrey O
Shaheen, Nicholas J
Fitzgerald, Rebecca C
Dellon, Evan S
Accuracy and Safety of the Cytosponge for Assessing Histologic Activity in Eosinophilic Esophagitis: A Two-Center Study
title Accuracy and Safety of the Cytosponge for Assessing Histologic Activity in Eosinophilic Esophagitis: A Two-Center Study
title_full Accuracy and Safety of the Cytosponge for Assessing Histologic Activity in Eosinophilic Esophagitis: A Two-Center Study
title_fullStr Accuracy and Safety of the Cytosponge for Assessing Histologic Activity in Eosinophilic Esophagitis: A Two-Center Study
title_full_unstemmed Accuracy and Safety of the Cytosponge for Assessing Histologic Activity in Eosinophilic Esophagitis: A Two-Center Study
title_short Accuracy and Safety of the Cytosponge for Assessing Histologic Activity in Eosinophilic Esophagitis: A Two-Center Study
title_sort accuracy and safety of the cytosponge for assessing histologic activity in eosinophilic esophagitis: a two-center study
topic Esophagus
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5848207/
https://www.ncbi.nlm.nih.gov/pubmed/28809387
http://dx.doi.org/10.1038/ajg.2017.244
work_keys_str_mv AT katzkadavida accuracyandsafetyofthecytospongeforassessinghistologicactivityineosinophilicesophagitisatwocenterstudy
AT smyrkthomasc accuracyandsafetyofthecytospongeforassessinghistologicactivityineosinophilicesophagitisatwocenterstudy
AT alexanderjeffreya accuracyandsafetyofthecytospongeforassessinghistologicactivityineosinophilicesophagitisatwocenterstudy
AT genodebram accuracyandsafetyofthecytospongeforassessinghistologicactivityineosinophilicesophagitisatwocenterstudy
AT beitiarosemarya accuracyandsafetyofthecytospongeforassessinghistologicactivityineosinophilicesophagitisatwocenterstudy
AT changaudreyo accuracyandsafetyofthecytospongeforassessinghistologicactivityineosinophilicesophagitisatwocenterstudy
AT shaheennicholasj accuracyandsafetyofthecytospongeforassessinghistologicactivityineosinophilicesophagitisatwocenterstudy
AT fitzgeraldrebeccac accuracyandsafetyofthecytospongeforassessinghistologicactivityineosinophilicesophagitisatwocenterstudy
AT dellonevans accuracyandsafetyofthecytospongeforassessinghistologicactivityineosinophilicesophagitisatwocenterstudy