Cargando…
Accuracy and Safety of the Cytosponge for Assessing Histologic Activity in Eosinophilic Esophagitis: A Two-Center Study
OBJECTIVES: Management of eosinophilic esophagitis (EoE) requires repeated endoscopic mucosal sampling to assess disease activity. A less invasive and expensive means of monitoring of EoE is required. The objective of this study was to assess the accuracy, safety, and tolerability of the cytosponge...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5848207/ https://www.ncbi.nlm.nih.gov/pubmed/28809387 http://dx.doi.org/10.1038/ajg.2017.244 |
_version_ | 1783305845043363840 |
---|---|
author | Katzka, David A Smyrk, Thomas C Alexander, Jeffrey A Geno, Debra M Beitia, RoseMary A Chang, Audrey O Shaheen, Nicholas J Fitzgerald, Rebecca C Dellon, Evan S |
author_facet | Katzka, David A Smyrk, Thomas C Alexander, Jeffrey A Geno, Debra M Beitia, RoseMary A Chang, Audrey O Shaheen, Nicholas J Fitzgerald, Rebecca C Dellon, Evan S |
author_sort | Katzka, David A |
collection | PubMed |
description | OBJECTIVES: Management of eosinophilic esophagitis (EoE) requires repeated endoscopic mucosal sampling to assess disease activity. A less invasive and expensive means of monitoring of EoE is required. The objective of this study was to assess the accuracy, safety, and tolerability of the cytosponge compared to endoscopy and biopsy for histologic assessment of EoE. METHODS: In this prospective two-center cross-sectional study, patients with known EoE underwent cytosponge sampling followed by endoscopy and biopsy. Sample adequacy and eosinophil counts (eos/HPF) were determined for both cytosponge and endoscopic samples. The cytosponge was assessed for diagnostic accuracy, safety, and patient preference as compared to endoscopy. RESULTS: Six patients (7%) failed to swallow the sponge. One hundred and five procedures were successfully performed in 80 patients (66% male, 100% white, 19% stricture). The cytosponge sample was adequate in 102 and the biopsy in 104; 101 procedures had adequate samples by both techniques. Fifty-seven biopsies were graded as active EoE with ≥15 eos/HPF as the gold standard. Eosinophil counts highly correlated between the biopsy and cytosponge (r=0.78, P<0.0001). Using a cutoff of ≤15 eos/HPF for inactive disease, the sensitivity and specificity of the cytosponge was 75% and 86%, respectively. Six patients had active EoE on cytosponge not found on biopsy. For biopsies with inactive EoE, the cytosponge identified 38/44. No complications occurred, and cytosponge endoscopic abrasion scores were low (0.34/4). Patients preferred cytosponge to endoscopy with higher rating scores (7.27 vs. 6.11, P=0.002). CONCLUSIONS: Compared to endoscopy with biopsy, cytosponge provided a minimally invasive, safe, well tolerated, and accurate method to assess EoE histologic activity. (ClinicalTrial.gov number NCT01585103). |
format | Online Article Text |
id | pubmed-5848207 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | Nature Publishing Group |
record_format | MEDLINE/PubMed |
spelling | pubmed-58482072018-03-15 Accuracy and Safety of the Cytosponge for Assessing Histologic Activity in Eosinophilic Esophagitis: A Two-Center Study Katzka, David A Smyrk, Thomas C Alexander, Jeffrey A Geno, Debra M Beitia, RoseMary A Chang, Audrey O Shaheen, Nicholas J Fitzgerald, Rebecca C Dellon, Evan S Am J Gastroenterol Esophagus OBJECTIVES: Management of eosinophilic esophagitis (EoE) requires repeated endoscopic mucosal sampling to assess disease activity. A less invasive and expensive means of monitoring of EoE is required. The objective of this study was to assess the accuracy, safety, and tolerability of the cytosponge compared to endoscopy and biopsy for histologic assessment of EoE. METHODS: In this prospective two-center cross-sectional study, patients with known EoE underwent cytosponge sampling followed by endoscopy and biopsy. Sample adequacy and eosinophil counts (eos/HPF) were determined for both cytosponge and endoscopic samples. The cytosponge was assessed for diagnostic accuracy, safety, and patient preference as compared to endoscopy. RESULTS: Six patients (7%) failed to swallow the sponge. One hundred and five procedures were successfully performed in 80 patients (66% male, 100% white, 19% stricture). The cytosponge sample was adequate in 102 and the biopsy in 104; 101 procedures had adequate samples by both techniques. Fifty-seven biopsies were graded as active EoE with ≥15 eos/HPF as the gold standard. Eosinophil counts highly correlated between the biopsy and cytosponge (r=0.78, P<0.0001). Using a cutoff of ≤15 eos/HPF for inactive disease, the sensitivity and specificity of the cytosponge was 75% and 86%, respectively. Six patients had active EoE on cytosponge not found on biopsy. For biopsies with inactive EoE, the cytosponge identified 38/44. No complications occurred, and cytosponge endoscopic abrasion scores were low (0.34/4). Patients preferred cytosponge to endoscopy with higher rating scores (7.27 vs. 6.11, P=0.002). CONCLUSIONS: Compared to endoscopy with biopsy, cytosponge provided a minimally invasive, safe, well tolerated, and accurate method to assess EoE histologic activity. (ClinicalTrial.gov number NCT01585103). Nature Publishing Group 2017 2017-08-15 /pmc/articles/PMC5848207/ /pubmed/28809387 http://dx.doi.org/10.1038/ajg.2017.244 Text en Copyright © 2017 American College of Gastroenterology |
spellingShingle | Esophagus Katzka, David A Smyrk, Thomas C Alexander, Jeffrey A Geno, Debra M Beitia, RoseMary A Chang, Audrey O Shaheen, Nicholas J Fitzgerald, Rebecca C Dellon, Evan S Accuracy and Safety of the Cytosponge for Assessing Histologic Activity in Eosinophilic Esophagitis: A Two-Center Study |
title | Accuracy and Safety of the Cytosponge for Assessing Histologic Activity in Eosinophilic Esophagitis: A Two-Center Study |
title_full | Accuracy and Safety of the Cytosponge for Assessing Histologic Activity in Eosinophilic Esophagitis: A Two-Center Study |
title_fullStr | Accuracy and Safety of the Cytosponge for Assessing Histologic Activity in Eosinophilic Esophagitis: A Two-Center Study |
title_full_unstemmed | Accuracy and Safety of the Cytosponge for Assessing Histologic Activity in Eosinophilic Esophagitis: A Two-Center Study |
title_short | Accuracy and Safety of the Cytosponge for Assessing Histologic Activity in Eosinophilic Esophagitis: A Two-Center Study |
title_sort | accuracy and safety of the cytosponge for assessing histologic activity in eosinophilic esophagitis: a two-center study |
topic | Esophagus |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5848207/ https://www.ncbi.nlm.nih.gov/pubmed/28809387 http://dx.doi.org/10.1038/ajg.2017.244 |
work_keys_str_mv | AT katzkadavida accuracyandsafetyofthecytospongeforassessinghistologicactivityineosinophilicesophagitisatwocenterstudy AT smyrkthomasc accuracyandsafetyofthecytospongeforassessinghistologicactivityineosinophilicesophagitisatwocenterstudy AT alexanderjeffreya accuracyandsafetyofthecytospongeforassessinghistologicactivityineosinophilicesophagitisatwocenterstudy AT genodebram accuracyandsafetyofthecytospongeforassessinghistologicactivityineosinophilicesophagitisatwocenterstudy AT beitiarosemarya accuracyandsafetyofthecytospongeforassessinghistologicactivityineosinophilicesophagitisatwocenterstudy AT changaudreyo accuracyandsafetyofthecytospongeforassessinghistologicactivityineosinophilicesophagitisatwocenterstudy AT shaheennicholasj accuracyandsafetyofthecytospongeforassessinghistologicactivityineosinophilicesophagitisatwocenterstudy AT fitzgeraldrebeccac accuracyandsafetyofthecytospongeforassessinghistologicactivityineosinophilicesophagitisatwocenterstudy AT dellonevans accuracyandsafetyofthecytospongeforassessinghistologicactivityineosinophilicesophagitisatwocenterstudy |