Cargando…
Optimized Calibration Procedure of the Damage Parameters of 6082-T6 Sheets
The constitutive equation of AA6082-T6 sheets is investigated by an extended Rousselier damage model. Previous research is mainly comprised of single-pull test specimens, notched tensile specimens, tensile specimens with a hole, and shear specimens. To decrease the natural material errors, a new spe...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5848945/ https://www.ncbi.nlm.nih.gov/pubmed/29415473 http://dx.doi.org/10.3390/ma11020248 |
_version_ | 1783305968360095744 |
---|---|
author | Xu, Fan Zhang, Hao Zhao, Shengdun Chen, Chao Cao, Miao Chen, Wei |
author_facet | Xu, Fan Zhang, Hao Zhao, Shengdun Chen, Chao Cao, Miao Chen, Wei |
author_sort | Xu, Fan |
collection | PubMed |
description | The constitutive equation of AA6082-T6 sheets is investigated by an extended Rousselier damage model. Previous research is mainly comprised of single-pull test specimens, notched tensile specimens, tensile specimens with a hole, and shear specimens. To decrease the natural material errors, a new specimen is used. In this paper, a clinched joint is regarded as a specimen to calibrate the initial void volume fraction [Formula: see text] and the shear damage parameter [Formula: see text] by using the orthogonal analysis method, which can reduce the simulation times and accuracy. It also reveals that the initial void volume fraction [Formula: see text] affects the void volume fraction in the neck and the groove of the clinched joint, and the shear damage parameter [Formula: see text] affects just the void volume fraction [Formula: see text] in the neck of the clinched joint. It checks the force-displacement curve, shape of the clinched joint, and the fracture location, and approves that these damage parameters can describe the deformation process, fracture location, and shape of the clinched joint. |
format | Online Article Text |
id | pubmed-5848945 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-58489452018-03-14 Optimized Calibration Procedure of the Damage Parameters of 6082-T6 Sheets Xu, Fan Zhang, Hao Zhao, Shengdun Chen, Chao Cao, Miao Chen, Wei Materials (Basel) Article The constitutive equation of AA6082-T6 sheets is investigated by an extended Rousselier damage model. Previous research is mainly comprised of single-pull test specimens, notched tensile specimens, tensile specimens with a hole, and shear specimens. To decrease the natural material errors, a new specimen is used. In this paper, a clinched joint is regarded as a specimen to calibrate the initial void volume fraction [Formula: see text] and the shear damage parameter [Formula: see text] by using the orthogonal analysis method, which can reduce the simulation times and accuracy. It also reveals that the initial void volume fraction [Formula: see text] affects the void volume fraction in the neck and the groove of the clinched joint, and the shear damage parameter [Formula: see text] affects just the void volume fraction [Formula: see text] in the neck of the clinched joint. It checks the force-displacement curve, shape of the clinched joint, and the fracture location, and approves that these damage parameters can describe the deformation process, fracture location, and shape of the clinched joint. MDPI 2018-02-06 /pmc/articles/PMC5848945/ /pubmed/29415473 http://dx.doi.org/10.3390/ma11020248 Text en © 2018 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Xu, Fan Zhang, Hao Zhao, Shengdun Chen, Chao Cao, Miao Chen, Wei Optimized Calibration Procedure of the Damage Parameters of 6082-T6 Sheets |
title | Optimized Calibration Procedure of the Damage Parameters of 6082-T6 Sheets |
title_full | Optimized Calibration Procedure of the Damage Parameters of 6082-T6 Sheets |
title_fullStr | Optimized Calibration Procedure of the Damage Parameters of 6082-T6 Sheets |
title_full_unstemmed | Optimized Calibration Procedure of the Damage Parameters of 6082-T6 Sheets |
title_short | Optimized Calibration Procedure of the Damage Parameters of 6082-T6 Sheets |
title_sort | optimized calibration procedure of the damage parameters of 6082-t6 sheets |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5848945/ https://www.ncbi.nlm.nih.gov/pubmed/29415473 http://dx.doi.org/10.3390/ma11020248 |
work_keys_str_mv | AT xufan optimizedcalibrationprocedureofthedamageparametersof6082t6sheets AT zhanghao optimizedcalibrationprocedureofthedamageparametersof6082t6sheets AT zhaoshengdun optimizedcalibrationprocedureofthedamageparametersof6082t6sheets AT chenchao optimizedcalibrationprocedureofthedamageparametersof6082t6sheets AT caomiao optimizedcalibrationprocedureofthedamageparametersof6082t6sheets AT chenwei optimizedcalibrationprocedureofthedamageparametersof6082t6sheets |