Cargando…
Preliminary Investigation of Poly-Ether-Ether-Ketone Based on Fused Deposition Modeling for Medical Applications
Poly-ether-ether-ketone (PEEK) fabricated by fused deposition modeling for medical applications was evaluated in terms of mechanical strength and in vitro cytotoxicity in this study. Orthogonal experiments were firstly designed to investigate the significant factors on tensile strength. Nozzle tempe...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5848985/ https://www.ncbi.nlm.nih.gov/pubmed/29439551 http://dx.doi.org/10.3390/ma11020288 |
_version_ | 1783305977822445568 |
---|---|
author | Zhao, Feng Li, Dichen Jin, Zhongmin |
author_facet | Zhao, Feng Li, Dichen Jin, Zhongmin |
author_sort | Zhao, Feng |
collection | PubMed |
description | Poly-ether-ether-ketone (PEEK) fabricated by fused deposition modeling for medical applications was evaluated in terms of mechanical strength and in vitro cytotoxicity in this study. Orthogonal experiments were firstly designed to investigate the significant factors on tensile strength. Nozzle temperature, platform temperature, and the filament diameter were tightly controlled for improved mechanical strength performance. These sensitive parameters affected the interlayer bonding and solid condition in the samples. Fourier transform infrared (FTIR) spectrometry analysis was secondly conducted to compare the functional groups in PEEK granules, filaments, and printed parts. In vitro cytotoxicity test was carried out at last, and no toxic substances were introduced during the printing process. |
format | Online Article Text |
id | pubmed-5848985 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-58489852018-03-14 Preliminary Investigation of Poly-Ether-Ether-Ketone Based on Fused Deposition Modeling for Medical Applications Zhao, Feng Li, Dichen Jin, Zhongmin Materials (Basel) Article Poly-ether-ether-ketone (PEEK) fabricated by fused deposition modeling for medical applications was evaluated in terms of mechanical strength and in vitro cytotoxicity in this study. Orthogonal experiments were firstly designed to investigate the significant factors on tensile strength. Nozzle temperature, platform temperature, and the filament diameter were tightly controlled for improved mechanical strength performance. These sensitive parameters affected the interlayer bonding and solid condition in the samples. Fourier transform infrared (FTIR) spectrometry analysis was secondly conducted to compare the functional groups in PEEK granules, filaments, and printed parts. In vitro cytotoxicity test was carried out at last, and no toxic substances were introduced during the printing process. MDPI 2018-02-12 /pmc/articles/PMC5848985/ /pubmed/29439551 http://dx.doi.org/10.3390/ma11020288 Text en © 2018 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Zhao, Feng Li, Dichen Jin, Zhongmin Preliminary Investigation of Poly-Ether-Ether-Ketone Based on Fused Deposition Modeling for Medical Applications |
title | Preliminary Investigation of Poly-Ether-Ether-Ketone Based on Fused Deposition Modeling for Medical Applications |
title_full | Preliminary Investigation of Poly-Ether-Ether-Ketone Based on Fused Deposition Modeling for Medical Applications |
title_fullStr | Preliminary Investigation of Poly-Ether-Ether-Ketone Based on Fused Deposition Modeling for Medical Applications |
title_full_unstemmed | Preliminary Investigation of Poly-Ether-Ether-Ketone Based on Fused Deposition Modeling for Medical Applications |
title_short | Preliminary Investigation of Poly-Ether-Ether-Ketone Based on Fused Deposition Modeling for Medical Applications |
title_sort | preliminary investigation of poly-ether-ether-ketone based on fused deposition modeling for medical applications |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5848985/ https://www.ncbi.nlm.nih.gov/pubmed/29439551 http://dx.doi.org/10.3390/ma11020288 |
work_keys_str_mv | AT zhaofeng preliminaryinvestigationofpolyetheretherketonebasedonfuseddepositionmodelingformedicalapplications AT lidichen preliminaryinvestigationofpolyetheretherketonebasedonfuseddepositionmodelingformedicalapplications AT jinzhongmin preliminaryinvestigationofpolyetheretherketonebasedonfuseddepositionmodelingformedicalapplications |