Protocol for Objective Measurement of Infants’ Physical Activity using Accelerometry

PURPOSE: This study aimed to evaluate methods for infants’ physical activity measurement based on accelerometry, including the minimum number of measurement days and placement of a wrist or ankle device. We also evaluated the acceptability of the device among infants and mothers. METHODS: A cross-se...

Descripción completa

Detalles Bibliográficos
Autores principales: RICARDO, LUIZA ISNARDI CARDOSO, DA SILVA, INÁCIO CROCHEMORE MOHNSAM, MARTINS, RAFAELA COSTA, WENDT, ANDREA, GONÇALVES, HELEN, HALLAL, PEDRO RODRIGUES CURI, WEHRMEISTER, FERNANDO CÉSAR
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Lippincott Williams & Wilkins 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5849301/
https://www.ncbi.nlm.nih.gov/pubmed/29206783
http://dx.doi.org/10.1249/MSS.0000000000001512
_version_ 1783306027236589568
author RICARDO, LUIZA ISNARDI CARDOSO
DA SILVA, INÁCIO CROCHEMORE MOHNSAM
MARTINS, RAFAELA COSTA
WENDT, ANDREA
GONÇALVES, HELEN
HALLAL, PEDRO RODRIGUES CURI
WEHRMEISTER, FERNANDO CÉSAR
author_facet RICARDO, LUIZA ISNARDI CARDOSO
DA SILVA, INÁCIO CROCHEMORE MOHNSAM
MARTINS, RAFAELA COSTA
WENDT, ANDREA
GONÇALVES, HELEN
HALLAL, PEDRO RODRIGUES CURI
WEHRMEISTER, FERNANDO CÉSAR
author_sort RICARDO, LUIZA ISNARDI CARDOSO
collection PubMed
description PURPOSE: This study aimed to evaluate methods for infants’ physical activity measurement based on accelerometry, including the minimum number of measurement days and placement of a wrist or ankle device. We also evaluated the acceptability of the device among infants and mothers. METHODS: A cross-sectional mixed-methods study was conducted on a convenience sample of 90 infants. Physical activity was measured using the Actigraph GT3X+ accelerometer placed on the wrist and/or ankle for 7 consecutive days (worn for 24 h), and a qualitative interview was performed to verify acceptability. The intraclass correlation coefficient (ICC) method and the Bland and Altman’s dispersion diagram were used to verify the minimum number of measurement days. All analyses were stratified by walking status. RESULTS: The mean (SD) age was 12.9 (1.70) months; the mean acceleration varied between 25.8 mg (95% confidence interval (CI), 14.3–52.7) and 27.3 mg (95% CI, 17.9–44.5) using the wrist placement, and between 24.9 mg (95% CI, 10.6–48.4) and 26.2 mg (95% CI, 11.7–65.6) using the ankle placement. The ICC results showed a lower acceleration variability between days among infants incapable of walking; they achieved an ICC of 0.80 with 1 d of measurement in both placements. Among those capable of walking, the minimum number of days to achieve an ICC of 0.80 was 2 d measured at the wrist (0.85; 95% CI, 0.71–0.93) and 3 d measured at the ankle (0.92; 95% CI, 0.84–0.96). The qualitative results pointed to the wrist placement as the preferred placement among the overall sample. CONCLUSIONS: Two and three measurement days with the accelerometer placed on the wrist and ankle, respectively, seemed to adequately represent a week of measurement. The accelerometer placed on the wrist had better acceptance by the infants and mothers.
format Online
Article
Text
id pubmed-5849301
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Lippincott Williams & Wilkins
record_format MEDLINE/PubMed
spelling pubmed-58493012018-07-11 Protocol for Objective Measurement of Infants’ Physical Activity using Accelerometry RICARDO, LUIZA ISNARDI CARDOSO DA SILVA, INÁCIO CROCHEMORE MOHNSAM MARTINS, RAFAELA COSTA WENDT, ANDREA GONÇALVES, HELEN HALLAL, PEDRO RODRIGUES CURI WEHRMEISTER, FERNANDO CÉSAR Med Sci Sports Exerc Applied Sciences PURPOSE: This study aimed to evaluate methods for infants’ physical activity measurement based on accelerometry, including the minimum number of measurement days and placement of a wrist or ankle device. We also evaluated the acceptability of the device among infants and mothers. METHODS: A cross-sectional mixed-methods study was conducted on a convenience sample of 90 infants. Physical activity was measured using the Actigraph GT3X+ accelerometer placed on the wrist and/or ankle for 7 consecutive days (worn for 24 h), and a qualitative interview was performed to verify acceptability. The intraclass correlation coefficient (ICC) method and the Bland and Altman’s dispersion diagram were used to verify the minimum number of measurement days. All analyses were stratified by walking status. RESULTS: The mean (SD) age was 12.9 (1.70) months; the mean acceleration varied between 25.8 mg (95% confidence interval (CI), 14.3–52.7) and 27.3 mg (95% CI, 17.9–44.5) using the wrist placement, and between 24.9 mg (95% CI, 10.6–48.4) and 26.2 mg (95% CI, 11.7–65.6) using the ankle placement. The ICC results showed a lower acceleration variability between days among infants incapable of walking; they achieved an ICC of 0.80 with 1 d of measurement in both placements. Among those capable of walking, the minimum number of days to achieve an ICC of 0.80 was 2 d measured at the wrist (0.85; 95% CI, 0.71–0.93) and 3 d measured at the ankle (0.92; 95% CI, 0.84–0.96). The qualitative results pointed to the wrist placement as the preferred placement among the overall sample. CONCLUSIONS: Two and three measurement days with the accelerometer placed on the wrist and ankle, respectively, seemed to adequately represent a week of measurement. The accelerometer placed on the wrist had better acceptance by the infants and mothers. Lippincott Williams & Wilkins 2018-05 2017-12-02 /pmc/articles/PMC5849301/ /pubmed/29206783 http://dx.doi.org/10.1249/MSS.0000000000001512 Text en Copyright © 2017 The Author(s). Published by Wolters Kluwer Health, Inc. on behalf of the American College of Sports Medicine. This is an open access article distributed under the Creative Commons Attribution License 4.0 (CCBY) (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Applied Sciences
RICARDO, LUIZA ISNARDI CARDOSO
DA SILVA, INÁCIO CROCHEMORE MOHNSAM
MARTINS, RAFAELA COSTA
WENDT, ANDREA
GONÇALVES, HELEN
HALLAL, PEDRO RODRIGUES CURI
WEHRMEISTER, FERNANDO CÉSAR
Protocol for Objective Measurement of Infants’ Physical Activity using Accelerometry
title Protocol for Objective Measurement of Infants’ Physical Activity using Accelerometry
title_full Protocol for Objective Measurement of Infants’ Physical Activity using Accelerometry
title_fullStr Protocol for Objective Measurement of Infants’ Physical Activity using Accelerometry
title_full_unstemmed Protocol for Objective Measurement of Infants’ Physical Activity using Accelerometry
title_short Protocol for Objective Measurement of Infants’ Physical Activity using Accelerometry
title_sort protocol for objective measurement of infants’ physical activity using accelerometry
topic Applied Sciences
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5849301/
https://www.ncbi.nlm.nih.gov/pubmed/29206783
http://dx.doi.org/10.1249/MSS.0000000000001512
work_keys_str_mv AT ricardoluizaisnardicardoso protocolforobjectivemeasurementofinfantsphysicalactivityusingaccelerometry
AT dasilvainaciocrochemoremohnsam protocolforobjectivemeasurementofinfantsphysicalactivityusingaccelerometry
AT martinsrafaelacosta protocolforobjectivemeasurementofinfantsphysicalactivityusingaccelerometry
AT wendtandrea protocolforobjectivemeasurementofinfantsphysicalactivityusingaccelerometry
AT goncalveshelen protocolforobjectivemeasurementofinfantsphysicalactivityusingaccelerometry
AT hallalpedrorodriguescuri protocolforobjectivemeasurementofinfantsphysicalactivityusingaccelerometry
AT wehrmeisterfernandocesar protocolforobjectivemeasurementofinfantsphysicalactivityusingaccelerometry