Cargando…
Protocol for Objective Measurement of Infants’ Physical Activity using Accelerometry
PURPOSE: This study aimed to evaluate methods for infants’ physical activity measurement based on accelerometry, including the minimum number of measurement days and placement of a wrist or ankle device. We also evaluated the acceptability of the device among infants and mothers. METHODS: A cross-se...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Lippincott Williams & Wilkins
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5849301/ https://www.ncbi.nlm.nih.gov/pubmed/29206783 http://dx.doi.org/10.1249/MSS.0000000000001512 |
_version_ | 1783306027236589568 |
---|---|
author | RICARDO, LUIZA ISNARDI CARDOSO DA SILVA, INÁCIO CROCHEMORE MOHNSAM MARTINS, RAFAELA COSTA WENDT, ANDREA GONÇALVES, HELEN HALLAL, PEDRO RODRIGUES CURI WEHRMEISTER, FERNANDO CÉSAR |
author_facet | RICARDO, LUIZA ISNARDI CARDOSO DA SILVA, INÁCIO CROCHEMORE MOHNSAM MARTINS, RAFAELA COSTA WENDT, ANDREA GONÇALVES, HELEN HALLAL, PEDRO RODRIGUES CURI WEHRMEISTER, FERNANDO CÉSAR |
author_sort | RICARDO, LUIZA ISNARDI CARDOSO |
collection | PubMed |
description | PURPOSE: This study aimed to evaluate methods for infants’ physical activity measurement based on accelerometry, including the minimum number of measurement days and placement of a wrist or ankle device. We also evaluated the acceptability of the device among infants and mothers. METHODS: A cross-sectional mixed-methods study was conducted on a convenience sample of 90 infants. Physical activity was measured using the Actigraph GT3X+ accelerometer placed on the wrist and/or ankle for 7 consecutive days (worn for 24 h), and a qualitative interview was performed to verify acceptability. The intraclass correlation coefficient (ICC) method and the Bland and Altman’s dispersion diagram were used to verify the minimum number of measurement days. All analyses were stratified by walking status. RESULTS: The mean (SD) age was 12.9 (1.70) months; the mean acceleration varied between 25.8 mg (95% confidence interval (CI), 14.3–52.7) and 27.3 mg (95% CI, 17.9–44.5) using the wrist placement, and between 24.9 mg (95% CI, 10.6–48.4) and 26.2 mg (95% CI, 11.7–65.6) using the ankle placement. The ICC results showed a lower acceleration variability between days among infants incapable of walking; they achieved an ICC of 0.80 with 1 d of measurement in both placements. Among those capable of walking, the minimum number of days to achieve an ICC of 0.80 was 2 d measured at the wrist (0.85; 95% CI, 0.71–0.93) and 3 d measured at the ankle (0.92; 95% CI, 0.84–0.96). The qualitative results pointed to the wrist placement as the preferred placement among the overall sample. CONCLUSIONS: Two and three measurement days with the accelerometer placed on the wrist and ankle, respectively, seemed to adequately represent a week of measurement. The accelerometer placed on the wrist had better acceptance by the infants and mothers. |
format | Online Article Text |
id | pubmed-5849301 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Lippincott Williams & Wilkins |
record_format | MEDLINE/PubMed |
spelling | pubmed-58493012018-07-11 Protocol for Objective Measurement of Infants’ Physical Activity using Accelerometry RICARDO, LUIZA ISNARDI CARDOSO DA SILVA, INÁCIO CROCHEMORE MOHNSAM MARTINS, RAFAELA COSTA WENDT, ANDREA GONÇALVES, HELEN HALLAL, PEDRO RODRIGUES CURI WEHRMEISTER, FERNANDO CÉSAR Med Sci Sports Exerc Applied Sciences PURPOSE: This study aimed to evaluate methods for infants’ physical activity measurement based on accelerometry, including the minimum number of measurement days and placement of a wrist or ankle device. We also evaluated the acceptability of the device among infants and mothers. METHODS: A cross-sectional mixed-methods study was conducted on a convenience sample of 90 infants. Physical activity was measured using the Actigraph GT3X+ accelerometer placed on the wrist and/or ankle for 7 consecutive days (worn for 24 h), and a qualitative interview was performed to verify acceptability. The intraclass correlation coefficient (ICC) method and the Bland and Altman’s dispersion diagram were used to verify the minimum number of measurement days. All analyses were stratified by walking status. RESULTS: The mean (SD) age was 12.9 (1.70) months; the mean acceleration varied between 25.8 mg (95% confidence interval (CI), 14.3–52.7) and 27.3 mg (95% CI, 17.9–44.5) using the wrist placement, and between 24.9 mg (95% CI, 10.6–48.4) and 26.2 mg (95% CI, 11.7–65.6) using the ankle placement. The ICC results showed a lower acceleration variability between days among infants incapable of walking; they achieved an ICC of 0.80 with 1 d of measurement in both placements. Among those capable of walking, the minimum number of days to achieve an ICC of 0.80 was 2 d measured at the wrist (0.85; 95% CI, 0.71–0.93) and 3 d measured at the ankle (0.92; 95% CI, 0.84–0.96). The qualitative results pointed to the wrist placement as the preferred placement among the overall sample. CONCLUSIONS: Two and three measurement days with the accelerometer placed on the wrist and ankle, respectively, seemed to adequately represent a week of measurement. The accelerometer placed on the wrist had better acceptance by the infants and mothers. Lippincott Williams & Wilkins 2018-05 2017-12-02 /pmc/articles/PMC5849301/ /pubmed/29206783 http://dx.doi.org/10.1249/MSS.0000000000001512 Text en Copyright © 2017 The Author(s). Published by Wolters Kluwer Health, Inc. on behalf of the American College of Sports Medicine. This is an open access article distributed under the Creative Commons Attribution License 4.0 (CCBY) (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Applied Sciences RICARDO, LUIZA ISNARDI CARDOSO DA SILVA, INÁCIO CROCHEMORE MOHNSAM MARTINS, RAFAELA COSTA WENDT, ANDREA GONÇALVES, HELEN HALLAL, PEDRO RODRIGUES CURI WEHRMEISTER, FERNANDO CÉSAR Protocol for Objective Measurement of Infants’ Physical Activity using Accelerometry |
title | Protocol for Objective Measurement of Infants’ Physical Activity using Accelerometry |
title_full | Protocol for Objective Measurement of Infants’ Physical Activity using Accelerometry |
title_fullStr | Protocol for Objective Measurement of Infants’ Physical Activity using Accelerometry |
title_full_unstemmed | Protocol for Objective Measurement of Infants’ Physical Activity using Accelerometry |
title_short | Protocol for Objective Measurement of Infants’ Physical Activity using Accelerometry |
title_sort | protocol for objective measurement of infants’ physical activity using accelerometry |
topic | Applied Sciences |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5849301/ https://www.ncbi.nlm.nih.gov/pubmed/29206783 http://dx.doi.org/10.1249/MSS.0000000000001512 |
work_keys_str_mv | AT ricardoluizaisnardicardoso protocolforobjectivemeasurementofinfantsphysicalactivityusingaccelerometry AT dasilvainaciocrochemoremohnsam protocolforobjectivemeasurementofinfantsphysicalactivityusingaccelerometry AT martinsrafaelacosta protocolforobjectivemeasurementofinfantsphysicalactivityusingaccelerometry AT wendtandrea protocolforobjectivemeasurementofinfantsphysicalactivityusingaccelerometry AT goncalveshelen protocolforobjectivemeasurementofinfantsphysicalactivityusingaccelerometry AT hallalpedrorodriguescuri protocolforobjectivemeasurementofinfantsphysicalactivityusingaccelerometry AT wehrmeisterfernandocesar protocolforobjectivemeasurementofinfantsphysicalactivityusingaccelerometry |