A study on the effect of detector resolution on gamma index passing rate for VMAT and IMRT QA

The main objectives of this study are to (1) analyze the sensitivity of various gamma index passing rates using different types of detectors having different resolutions and (2) investigate the sensitivity of various gamma criteria in intensity‐modulated radiation therapy (IMRT) and volumetrically m...

Descripción completa

Detalles Bibliográficos
Autores principales: Woon, WuiAnn, Ravindran, Paul B, Ekayanake, Piyasiri, S, Vikraman, Lim, Yivonne YF, Khalid, Jamsari
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5849818/
https://www.ncbi.nlm.nih.gov/pubmed/29460465
http://dx.doi.org/10.1002/acm2.12285
_version_ 1783306111350210560
author Woon, WuiAnn
Ravindran, Paul B
Ekayanake, Piyasiri
S, Vikraman
Lim, Yivonne YF
Khalid, Jamsari
author_facet Woon, WuiAnn
Ravindran, Paul B
Ekayanake, Piyasiri
S, Vikraman
Lim, Yivonne YF
Khalid, Jamsari
author_sort Woon, WuiAnn
collection PubMed
description The main objectives of this study are to (1) analyze the sensitivity of various gamma index passing rates using different types of detectors having different resolutions and (2) investigate the sensitivity of various gamma criteria in intensity‐modulated radiation therapy (IMRT) and volumetrically modulated arc therapy (VMAT) quality assurance (QA) for the detection of systematic multileaf collimator (MLC) errors using an electronic portal imaging device (EPID) and planar (MapCheck2) and cylindrical (ArcCheck) diode arrays. We also evaluated whether the correlation between the gamma passing rate (%GP) and the percentage dose error (%DE) of the dose–volume histogram (DVH) metrics was affected by the finite spatial resolution of the array detectors. We deliberately simulated systematic MLC errors of 0.25 mm, 0.50 mm, 0.75 mm, and 1 mm in five clinical nasopharyngeal carcinoma cases, thus creating 40 plans with systematic MLC errors. All measurements were analyzed field by field using gamma criteria of 3%/3 mm, 3%/2 mm, 3%/1 mm, and 2%/2 mm, with a passing rate of 90% applied as the action level. Our results showed that 3%/1 mm is the most sensitive criterion for the detection of systematic MLC errors when using EPID, with the steepest slope from the best‐fit line and an area under the receiver operating characteristic (ROC) curve >0.95. With respect to the 3%/1 mm criterion, a strong correlation between %GP and %DE of the DVH metrics was observed only when using the EPID. However, with respect to the same criteria, a 0.75 mm systematic MLC error can go undetected when using MapCheck2 and ArcCheck, with an area under the ROC curve <0.75. Furthermore, a lack of correlation between %GP and %DE of the DVH metrics was observed in MapCheck2 and ArcCheck. In conclusion, low‐spatial resolution detectors can affect the results of a per‐field gamma analysis and render the analysis unable to accurately separate erroneous and non‐erroneous plans. Meeting these new sensitive criteria is expected to ensure clinically acceptable dose errors.
format Online
Article
Text
id pubmed-5849818
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-58498182018-04-02 A study on the effect of detector resolution on gamma index passing rate for VMAT and IMRT QA Woon, WuiAnn Ravindran, Paul B Ekayanake, Piyasiri S, Vikraman Lim, Yivonne YF Khalid, Jamsari J Appl Clin Med Phys Radiation Oncology Physics The main objectives of this study are to (1) analyze the sensitivity of various gamma index passing rates using different types of detectors having different resolutions and (2) investigate the sensitivity of various gamma criteria in intensity‐modulated radiation therapy (IMRT) and volumetrically modulated arc therapy (VMAT) quality assurance (QA) for the detection of systematic multileaf collimator (MLC) errors using an electronic portal imaging device (EPID) and planar (MapCheck2) and cylindrical (ArcCheck) diode arrays. We also evaluated whether the correlation between the gamma passing rate (%GP) and the percentage dose error (%DE) of the dose–volume histogram (DVH) metrics was affected by the finite spatial resolution of the array detectors. We deliberately simulated systematic MLC errors of 0.25 mm, 0.50 mm, 0.75 mm, and 1 mm in five clinical nasopharyngeal carcinoma cases, thus creating 40 plans with systematic MLC errors. All measurements were analyzed field by field using gamma criteria of 3%/3 mm, 3%/2 mm, 3%/1 mm, and 2%/2 mm, with a passing rate of 90% applied as the action level. Our results showed that 3%/1 mm is the most sensitive criterion for the detection of systematic MLC errors when using EPID, with the steepest slope from the best‐fit line and an area under the receiver operating characteristic (ROC) curve >0.95. With respect to the 3%/1 mm criterion, a strong correlation between %GP and %DE of the DVH metrics was observed only when using the EPID. However, with respect to the same criteria, a 0.75 mm systematic MLC error can go undetected when using MapCheck2 and ArcCheck, with an area under the ROC curve <0.75. Furthermore, a lack of correlation between %GP and %DE of the DVH metrics was observed in MapCheck2 and ArcCheck. In conclusion, low‐spatial resolution detectors can affect the results of a per‐field gamma analysis and render the analysis unable to accurately separate erroneous and non‐erroneous plans. Meeting these new sensitive criteria is expected to ensure clinically acceptable dose errors. John Wiley and Sons Inc. 2018-02-20 /pmc/articles/PMC5849818/ /pubmed/29460465 http://dx.doi.org/10.1002/acm2.12285 Text en © 2018 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine. This is an open access article under the terms of the Creative Commons Attribution (http://creativecommons.org/licenses/by/4.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Radiation Oncology Physics
Woon, WuiAnn
Ravindran, Paul B
Ekayanake, Piyasiri
S, Vikraman
Lim, Yivonne YF
Khalid, Jamsari
A study on the effect of detector resolution on gamma index passing rate for VMAT and IMRT QA
title A study on the effect of detector resolution on gamma index passing rate for VMAT and IMRT QA
title_full A study on the effect of detector resolution on gamma index passing rate for VMAT and IMRT QA
title_fullStr A study on the effect of detector resolution on gamma index passing rate for VMAT and IMRT QA
title_full_unstemmed A study on the effect of detector resolution on gamma index passing rate for VMAT and IMRT QA
title_short A study on the effect of detector resolution on gamma index passing rate for VMAT and IMRT QA
title_sort study on the effect of detector resolution on gamma index passing rate for vmat and imrt qa
topic Radiation Oncology Physics
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5849818/
https://www.ncbi.nlm.nih.gov/pubmed/29460465
http://dx.doi.org/10.1002/acm2.12285
work_keys_str_mv AT woonwuiann astudyontheeffectofdetectorresolutionongammaindexpassingrateforvmatandimrtqa
AT ravindranpaulb astudyontheeffectofdetectorresolutionongammaindexpassingrateforvmatandimrtqa
AT ekayanakepiyasiri astudyontheeffectofdetectorresolutionongammaindexpassingrateforvmatandimrtqa
AT svikraman astudyontheeffectofdetectorresolutionongammaindexpassingrateforvmatandimrtqa
AT limyivonneyf astudyontheeffectofdetectorresolutionongammaindexpassingrateforvmatandimrtqa
AT khalidjamsari astudyontheeffectofdetectorresolutionongammaindexpassingrateforvmatandimrtqa
AT woonwuiann studyontheeffectofdetectorresolutionongammaindexpassingrateforvmatandimrtqa
AT ravindranpaulb studyontheeffectofdetectorresolutionongammaindexpassingrateforvmatandimrtqa
AT ekayanakepiyasiri studyontheeffectofdetectorresolutionongammaindexpassingrateforvmatandimrtqa
AT svikraman studyontheeffectofdetectorresolutionongammaindexpassingrateforvmatandimrtqa
AT limyivonneyf studyontheeffectofdetectorresolutionongammaindexpassingrateforvmatandimrtqa
AT khalidjamsari studyontheeffectofdetectorresolutionongammaindexpassingrateforvmatandimrtqa