Cargando…

Volumetric‐based image guidance is superior to marker‐based alignments for stereotactic body radiotherapy of prostate cancer

PURPOSES: The aim of this study was to evaluate a dual marker‐based and soft‐tissue based image guidance for inter‐fractional corrections in stereotactic body radiotherapy (SBRT) of prostate cancer. METHODS/MATERIALS: We reviewed 18 patients treated with SBRT for prostate cancer. An endorectal ballo...

Descripción completa

Detalles Bibliográficos
Autores principales: Li, Wen, Lu, Lan, Stephans, Kevin L, Sharma, Naveen, Vassil, Andrew, Shen, Zhilei Liu, Stockham, Abigail, Djemil, Toufik, Tendulkar, Rahul D, Xia, Ping
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5849820/
https://www.ncbi.nlm.nih.gov/pubmed/29450961
http://dx.doi.org/10.1002/acm2.12280
_version_ 1783306111811584000
author Li, Wen
Lu, Lan
Stephans, Kevin L
Sharma, Naveen
Vassil, Andrew
Shen, Zhilei Liu
Stockham, Abigail
Djemil, Toufik
Tendulkar, Rahul D
Xia, Ping
author_facet Li, Wen
Lu, Lan
Stephans, Kevin L
Sharma, Naveen
Vassil, Andrew
Shen, Zhilei Liu
Stockham, Abigail
Djemil, Toufik
Tendulkar, Rahul D
Xia, Ping
author_sort Li, Wen
collection PubMed
description PURPOSES: The aim of this study was to evaluate a dual marker‐based and soft‐tissue based image guidance for inter‐fractional corrections in stereotactic body radiotherapy (SBRT) of prostate cancer. METHODS/MATERIALS: We reviewed 18 patients treated with SBRT for prostate cancer. An endorectal balloon was inserted at simulation and each treatment. Planning margins were 3 mm/0 mm posteriorly. Prior to each treatment, a dual image guidance protocol was applied to align three makers using stereoscopic x ray images and then to the soft tissue using kilo‐voltage cone beam CT (kV‐CBCT). After treatment, prostate (CTV), rectal wall, and bladder were delineated on each kV‐CBCT, and delivered dose was recalculated. Dosimetric endpoints were analyzed, including V(36.25 Gy) for prostate, and D(0.03 cc) for bladder and rectal wall. RESULTS: Following initial marker alignment, additional translational shifts were applied to 22 of 84 fractions after kV‐CBCT. Among the 22 fractions, ten fractions exceeded 3 mm shifts in any direction, including one in the left‐right direction, four in the superior‐inferior direction, and five in the anterior‐posterior direction. With and without the additional kV‐CBCT shifts, the average V(36.25 Gy) of the prostate for the 22 fractions was 97.6 ± 2.6% with the kV x ray image alone, and was 98.1 ± 2.4% after applying the additional kV‐CBCT shifts. The improvement was borderline statistical significance using Wilcoxon signed‐rank test (P = 0.007). D(0.03 cc) was 45.8 ± 6.3 Gy vs. 45.1 ± 4.9 Gy for the rectal wall; and 49.5 ± 8.6 Gy vs. 49.3 ± 7.9 Gy for the bladder before and after applying kV‐CBCT shifts. CONCLUSIONS: Marker‐based alignment alone is not sufficient. Additional adjustments are needed for some patients based kV‐CBCT.
format Online
Article
Text
id pubmed-5849820
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-58498202018-04-02 Volumetric‐based image guidance is superior to marker‐based alignments for stereotactic body radiotherapy of prostate cancer Li, Wen Lu, Lan Stephans, Kevin L Sharma, Naveen Vassil, Andrew Shen, Zhilei Liu Stockham, Abigail Djemil, Toufik Tendulkar, Rahul D Xia, Ping J Appl Clin Med Phys Radiation Oncology Physics PURPOSES: The aim of this study was to evaluate a dual marker‐based and soft‐tissue based image guidance for inter‐fractional corrections in stereotactic body radiotherapy (SBRT) of prostate cancer. METHODS/MATERIALS: We reviewed 18 patients treated with SBRT for prostate cancer. An endorectal balloon was inserted at simulation and each treatment. Planning margins were 3 mm/0 mm posteriorly. Prior to each treatment, a dual image guidance protocol was applied to align three makers using stereoscopic x ray images and then to the soft tissue using kilo‐voltage cone beam CT (kV‐CBCT). After treatment, prostate (CTV), rectal wall, and bladder were delineated on each kV‐CBCT, and delivered dose was recalculated. Dosimetric endpoints were analyzed, including V(36.25 Gy) for prostate, and D(0.03 cc) for bladder and rectal wall. RESULTS: Following initial marker alignment, additional translational shifts were applied to 22 of 84 fractions after kV‐CBCT. Among the 22 fractions, ten fractions exceeded 3 mm shifts in any direction, including one in the left‐right direction, four in the superior‐inferior direction, and five in the anterior‐posterior direction. With and without the additional kV‐CBCT shifts, the average V(36.25 Gy) of the prostate for the 22 fractions was 97.6 ± 2.6% with the kV x ray image alone, and was 98.1 ± 2.4% after applying the additional kV‐CBCT shifts. The improvement was borderline statistical significance using Wilcoxon signed‐rank test (P = 0.007). D(0.03 cc) was 45.8 ± 6.3 Gy vs. 45.1 ± 4.9 Gy for the rectal wall; and 49.5 ± 8.6 Gy vs. 49.3 ± 7.9 Gy for the bladder before and after applying kV‐CBCT shifts. CONCLUSIONS: Marker‐based alignment alone is not sufficient. Additional adjustments are needed for some patients based kV‐CBCT. John Wiley and Sons Inc. 2018-02-15 /pmc/articles/PMC5849820/ /pubmed/29450961 http://dx.doi.org/10.1002/acm2.12280 Text en © 2018 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine. This is an open access article under the terms of the Creative Commons Attribution (http://creativecommons.org/licenses/by/4.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Radiation Oncology Physics
Li, Wen
Lu, Lan
Stephans, Kevin L
Sharma, Naveen
Vassil, Andrew
Shen, Zhilei Liu
Stockham, Abigail
Djemil, Toufik
Tendulkar, Rahul D
Xia, Ping
Volumetric‐based image guidance is superior to marker‐based alignments for stereotactic body radiotherapy of prostate cancer
title Volumetric‐based image guidance is superior to marker‐based alignments for stereotactic body radiotherapy of prostate cancer
title_full Volumetric‐based image guidance is superior to marker‐based alignments for stereotactic body radiotherapy of prostate cancer
title_fullStr Volumetric‐based image guidance is superior to marker‐based alignments for stereotactic body radiotherapy of prostate cancer
title_full_unstemmed Volumetric‐based image guidance is superior to marker‐based alignments for stereotactic body radiotherapy of prostate cancer
title_short Volumetric‐based image guidance is superior to marker‐based alignments for stereotactic body radiotherapy of prostate cancer
title_sort volumetric‐based image guidance is superior to marker‐based alignments for stereotactic body radiotherapy of prostate cancer
topic Radiation Oncology Physics
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5849820/
https://www.ncbi.nlm.nih.gov/pubmed/29450961
http://dx.doi.org/10.1002/acm2.12280
work_keys_str_mv AT liwen volumetricbasedimageguidanceissuperiortomarkerbasedalignmentsforstereotacticbodyradiotherapyofprostatecancer
AT lulan volumetricbasedimageguidanceissuperiortomarkerbasedalignmentsforstereotacticbodyradiotherapyofprostatecancer
AT stephanskevinl volumetricbasedimageguidanceissuperiortomarkerbasedalignmentsforstereotacticbodyradiotherapyofprostatecancer
AT sharmanaveen volumetricbasedimageguidanceissuperiortomarkerbasedalignmentsforstereotacticbodyradiotherapyofprostatecancer
AT vassilandrew volumetricbasedimageguidanceissuperiortomarkerbasedalignmentsforstereotacticbodyradiotherapyofprostatecancer
AT shenzhileiliu volumetricbasedimageguidanceissuperiortomarkerbasedalignmentsforstereotacticbodyradiotherapyofprostatecancer
AT stockhamabigail volumetricbasedimageguidanceissuperiortomarkerbasedalignmentsforstereotacticbodyradiotherapyofprostatecancer
AT djemiltoufik volumetricbasedimageguidanceissuperiortomarkerbasedalignmentsforstereotacticbodyradiotherapyofprostatecancer
AT tendulkarrahuld volumetricbasedimageguidanceissuperiortomarkerbasedalignmentsforstereotacticbodyradiotherapyofprostatecancer
AT xiaping volumetricbasedimageguidanceissuperiortomarkerbasedalignmentsforstereotacticbodyradiotherapyofprostatecancer