Shielding verification and neutron dose evaluation of the Mevion S250 proton therapy unit

For passive scattering proton therapy systems, neutron contamination is the main concern both from an occupational and patient safety perspective. The Mevion S250 compact proton therapy system is the first of its kind, offering an in‐room cyclotron design which prompts more concern for shielding ass...

Descripción completa

Detalles Bibliográficos
Autores principales: Prusator, Michael T., Ahmad, Salahuddin, Chen, Yong
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5849833/
https://www.ncbi.nlm.nih.gov/pubmed/29468842
http://dx.doi.org/10.1002/acm2.12256
_version_ 1783306114848260096
author Prusator, Michael T.
Ahmad, Salahuddin
Chen, Yong
author_facet Prusator, Michael T.
Ahmad, Salahuddin
Chen, Yong
author_sort Prusator, Michael T.
collection PubMed
description For passive scattering proton therapy systems, neutron contamination is the main concern both from an occupational and patient safety perspective. The Mevion S250 compact proton therapy system is the first of its kind, offering an in‐room cyclotron design which prompts more concern for shielding assessment. The purpose of this study was to accomplish an in‐depth evaluation of both the shielding design and in‐room neutron production at our facility using both Monte Carlo simulation and measurement. We found that the shielding in place at our facility is adequate, with simulated annual neutron ambient dose equivalents at 30 cm outside wall/door perimeter ranging from background to 0.07 mSv and measured dose equivalents ranging from background to 0.06 mSv. The in‐room measurements reveal that the H*/D decreases when the distance from isocenter and field size increases. Furthermore, the H*/D generally increases when the angle around isocenter increases. Our results from in‐room measurements show consistent trends with our Monte Carlo model of the Mevion system.
format Online
Article
Text
id pubmed-5849833
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-58498332018-04-02 Shielding verification and neutron dose evaluation of the Mevion S250 proton therapy unit Prusator, Michael T. Ahmad, Salahuddin Chen, Yong J Appl Clin Med Phys Radiation Protection & Regulations For passive scattering proton therapy systems, neutron contamination is the main concern both from an occupational and patient safety perspective. The Mevion S250 compact proton therapy system is the first of its kind, offering an in‐room cyclotron design which prompts more concern for shielding assessment. The purpose of this study was to accomplish an in‐depth evaluation of both the shielding design and in‐room neutron production at our facility using both Monte Carlo simulation and measurement. We found that the shielding in place at our facility is adequate, with simulated annual neutron ambient dose equivalents at 30 cm outside wall/door perimeter ranging from background to 0.07 mSv and measured dose equivalents ranging from background to 0.06 mSv. The in‐room measurements reveal that the H*/D decreases when the distance from isocenter and field size increases. Furthermore, the H*/D generally increases when the angle around isocenter increases. Our results from in‐room measurements show consistent trends with our Monte Carlo model of the Mevion system. John Wiley and Sons Inc. 2018-02-22 /pmc/articles/PMC5849833/ /pubmed/29468842 http://dx.doi.org/10.1002/acm2.12256 Text en © 2018 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine. This is an open access article under the terms of the Creative Commons Attribution (http://creativecommons.org/licenses/by/4.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Radiation Protection & Regulations
Prusator, Michael T.
Ahmad, Salahuddin
Chen, Yong
Shielding verification and neutron dose evaluation of the Mevion S250 proton therapy unit
title Shielding verification and neutron dose evaluation of the Mevion S250 proton therapy unit
title_full Shielding verification and neutron dose evaluation of the Mevion S250 proton therapy unit
title_fullStr Shielding verification and neutron dose evaluation of the Mevion S250 proton therapy unit
title_full_unstemmed Shielding verification and neutron dose evaluation of the Mevion S250 proton therapy unit
title_short Shielding verification and neutron dose evaluation of the Mevion S250 proton therapy unit
title_sort shielding verification and neutron dose evaluation of the mevion s250 proton therapy unit
topic Radiation Protection & Regulations
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5849833/
https://www.ncbi.nlm.nih.gov/pubmed/29468842
http://dx.doi.org/10.1002/acm2.12256
work_keys_str_mv AT prusatormichaelt shieldingverificationandneutrondoseevaluationofthemevions250protontherapyunit
AT ahmadsalahuddin shieldingverificationandneutrondoseevaluationofthemevions250protontherapyunit
AT chenyong shieldingverificationandneutrondoseevaluationofthemevions250protontherapyunit