Cargando…

Volumetric modulated arc therapy treatment planning of thoracic vertebral metastases using stereotactic body radiotherapy

PURPOSE/OBJECTIVES: To retrospectively evaluate the plan quality, treatment efficiency, and accuracy of volumetric modulated arc therapy (VMAT) plans for thoracic spine metastases using stereotactic body radiotherapy (SBRT). MATERIALS/METHODS: Seven patients with thoracic vertebral metastases treate...

Descripción completa

Detalles Bibliográficos
Autores principales: Mallory, Matthew, Pokhrel, Damodar, Badkul, Rajeev, Jiang, Hongyu, Lominska, Christopher, Wang, Fen
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5849835/
https://www.ncbi.nlm.nih.gov/pubmed/29349867
http://dx.doi.org/10.1002/acm2.12252
_version_ 1783306115314876416
author Mallory, Matthew
Pokhrel, Damodar
Badkul, Rajeev
Jiang, Hongyu
Lominska, Christopher
Wang, Fen
author_facet Mallory, Matthew
Pokhrel, Damodar
Badkul, Rajeev
Jiang, Hongyu
Lominska, Christopher
Wang, Fen
author_sort Mallory, Matthew
collection PubMed
description PURPOSE/OBJECTIVES: To retrospectively evaluate the plan quality, treatment efficiency, and accuracy of volumetric modulated arc therapy (VMAT) plans for thoracic spine metastases using stereotactic body radiotherapy (SBRT). MATERIALS/METHODS: Seven patients with thoracic vertebral metastases treated with noncoplanar hybrid arcs (NCHA) (1 to 2 3D‐conformal partial arcs +7 to 9 IMRT beams) were re‐optimized with VMAT plans using three coplanar arcs. Tumors were located between T2 and T7 and PTVs ranged between 24.3 and 240.1 cc (median 48.1 cc). All prescriptions were 30 Gy in 5 fractions with 6 MV beams treated using the Novalis Tx linac equipped with high definition multileaf collimators (HDMLC). MR images were fused with planning CTs for target and OAR contouring. Plans were compared for target coverage using conformality index (CI), homogeneity index (HI), D90, D98, D2, and Dmedian. Normal tissue sparing was evaluated by comparing doses to the spinal cord (Dmax, D0.35, and D1.2 cc), esophagus (Dmax and D5 cc), heart (Dmax, D15 cc), and lung (V5 and V10). Data analysis was performed with a two‐sided t‐test for each set of parameters. Dose delivery efficiency and accuracy of each VMAT plan was assessed via quality assurance (QA) using a MapCHECK device. The Beam‐on time (BOT) was recorded, and a gamma index was used to compare dose agreement between the planned and measured doses. RESULTS: VMAT plans resulted in improved CI (1.02 vs. 1.36, P = 0.05), HI (0.14 vs. 0.27, P = 0.01), D98 (28.4 vs. 26.8 Gy, P = 0.03), D2 (32.9 vs. 36.0 Gy, P = 0.02), and Dmedian (31.4 vs. 33.7 Gy, P = 0.01). D90 was improved but not statistically significant (30.4 vs. 31.0 Gy, P = 0.38). VMAT plans showed statistically significant improvements in normal tissue sparing: Esophagus D(max) (22.5 vs. 27.0 Gy, P = 0.03), Esophagus 5 cc (17.6 vs. 21.5 Gy, P = 0.02), and Heart D(max) (13.1 vs. 15.8 Gy, P = 0.03). Improvements were also observed in spinal cord and lung sparing as well but were not statistically significant. The BOT showed significant reduction for VMAT, 4.7 ± 0.6 min vs. 7.1 ± 1 min for NCHA (not accounting for couch kicks). VMAT plans demonstrated an accurate dose delivery of 95.5 ± 1.0% for clinical gamma passing rate of 3%/3 mm criteria, which was similar to NCHA plans. CONCLUSIONS: VMAT plans have shown improved dose distributions and normal tissue sparing compared to NCHA plans. Significant reductions in treatment time could potentially minimize patient discomfort and intrafraction movement errors. VMAT planning for SBRT is an attractive option for the treatment of metastases to thoracic vertebrae, and further investigation using alternative fractionation schedules is warranted.
format Online
Article
Text
id pubmed-5849835
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-58498352018-04-02 Volumetric modulated arc therapy treatment planning of thoracic vertebral metastases using stereotactic body radiotherapy Mallory, Matthew Pokhrel, Damodar Badkul, Rajeev Jiang, Hongyu Lominska, Christopher Wang, Fen J Appl Clin Med Phys Radiation Oncology Physics PURPOSE/OBJECTIVES: To retrospectively evaluate the plan quality, treatment efficiency, and accuracy of volumetric modulated arc therapy (VMAT) plans for thoracic spine metastases using stereotactic body radiotherapy (SBRT). MATERIALS/METHODS: Seven patients with thoracic vertebral metastases treated with noncoplanar hybrid arcs (NCHA) (1 to 2 3D‐conformal partial arcs +7 to 9 IMRT beams) were re‐optimized with VMAT plans using three coplanar arcs. Tumors were located between T2 and T7 and PTVs ranged between 24.3 and 240.1 cc (median 48.1 cc). All prescriptions were 30 Gy in 5 fractions with 6 MV beams treated using the Novalis Tx linac equipped with high definition multileaf collimators (HDMLC). MR images were fused with planning CTs for target and OAR contouring. Plans were compared for target coverage using conformality index (CI), homogeneity index (HI), D90, D98, D2, and Dmedian. Normal tissue sparing was evaluated by comparing doses to the spinal cord (Dmax, D0.35, and D1.2 cc), esophagus (Dmax and D5 cc), heart (Dmax, D15 cc), and lung (V5 and V10). Data analysis was performed with a two‐sided t‐test for each set of parameters. Dose delivery efficiency and accuracy of each VMAT plan was assessed via quality assurance (QA) using a MapCHECK device. The Beam‐on time (BOT) was recorded, and a gamma index was used to compare dose agreement between the planned and measured doses. RESULTS: VMAT plans resulted in improved CI (1.02 vs. 1.36, P = 0.05), HI (0.14 vs. 0.27, P = 0.01), D98 (28.4 vs. 26.8 Gy, P = 0.03), D2 (32.9 vs. 36.0 Gy, P = 0.02), and Dmedian (31.4 vs. 33.7 Gy, P = 0.01). D90 was improved but not statistically significant (30.4 vs. 31.0 Gy, P = 0.38). VMAT plans showed statistically significant improvements in normal tissue sparing: Esophagus D(max) (22.5 vs. 27.0 Gy, P = 0.03), Esophagus 5 cc (17.6 vs. 21.5 Gy, P = 0.02), and Heart D(max) (13.1 vs. 15.8 Gy, P = 0.03). Improvements were also observed in spinal cord and lung sparing as well but were not statistically significant. The BOT showed significant reduction for VMAT, 4.7 ± 0.6 min vs. 7.1 ± 1 min for NCHA (not accounting for couch kicks). VMAT plans demonstrated an accurate dose delivery of 95.5 ± 1.0% for clinical gamma passing rate of 3%/3 mm criteria, which was similar to NCHA plans. CONCLUSIONS: VMAT plans have shown improved dose distributions and normal tissue sparing compared to NCHA plans. Significant reductions in treatment time could potentially minimize patient discomfort and intrafraction movement errors. VMAT planning for SBRT is an attractive option for the treatment of metastases to thoracic vertebrae, and further investigation using alternative fractionation schedules is warranted. John Wiley and Sons Inc. 2018-01-19 /pmc/articles/PMC5849835/ /pubmed/29349867 http://dx.doi.org/10.1002/acm2.12252 Text en © 2018 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine. This is an open access article under the terms of the Creative Commons Attribution (http://creativecommons.org/licenses/by/4.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Radiation Oncology Physics
Mallory, Matthew
Pokhrel, Damodar
Badkul, Rajeev
Jiang, Hongyu
Lominska, Christopher
Wang, Fen
Volumetric modulated arc therapy treatment planning of thoracic vertebral metastases using stereotactic body radiotherapy
title Volumetric modulated arc therapy treatment planning of thoracic vertebral metastases using stereotactic body radiotherapy
title_full Volumetric modulated arc therapy treatment planning of thoracic vertebral metastases using stereotactic body radiotherapy
title_fullStr Volumetric modulated arc therapy treatment planning of thoracic vertebral metastases using stereotactic body radiotherapy
title_full_unstemmed Volumetric modulated arc therapy treatment planning of thoracic vertebral metastases using stereotactic body radiotherapy
title_short Volumetric modulated arc therapy treatment planning of thoracic vertebral metastases using stereotactic body radiotherapy
title_sort volumetric modulated arc therapy treatment planning of thoracic vertebral metastases using stereotactic body radiotherapy
topic Radiation Oncology Physics
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5849835/
https://www.ncbi.nlm.nih.gov/pubmed/29349867
http://dx.doi.org/10.1002/acm2.12252
work_keys_str_mv AT mallorymatthew volumetricmodulatedarctherapytreatmentplanningofthoracicvertebralmetastasesusingstereotacticbodyradiotherapy
AT pokhreldamodar volumetricmodulatedarctherapytreatmentplanningofthoracicvertebralmetastasesusingstereotacticbodyradiotherapy
AT badkulrajeev volumetricmodulatedarctherapytreatmentplanningofthoracicvertebralmetastasesusingstereotacticbodyradiotherapy
AT jianghongyu volumetricmodulatedarctherapytreatmentplanningofthoracicvertebralmetastasesusingstereotacticbodyradiotherapy
AT lominskachristopher volumetricmodulatedarctherapytreatmentplanningofthoracicvertebralmetastasesusingstereotacticbodyradiotherapy
AT wangfen volumetricmodulatedarctherapytreatmentplanningofthoracicvertebralmetastasesusingstereotacticbodyradiotherapy