A simple technique to improve calculated skin dose accuracy in a commercial treatment planning system
Radiation dermatitis during radiotherapy is correlated with skin dose and is a common clinical problem for head and neck and thoracic cancer patients. Therefore, accurate prediction of skin dose during treatment planning is clinically important. The objective of this study is to evaluate the accurac...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5849836/ https://www.ncbi.nlm.nih.gov/pubmed/29411506 http://dx.doi.org/10.1002/acm2.12275 |
_version_ | 1783306115543465984 |
---|---|
author | Wang, Lilie Cmelak, Anthony J. Ding, George X. |
author_facet | Wang, Lilie Cmelak, Anthony J. Ding, George X. |
author_sort | Wang, Lilie |
collection | PubMed |
description | Radiation dermatitis during radiotherapy is correlated with skin dose and is a common clinical problem for head and neck and thoracic cancer patients. Therefore, accurate prediction of skin dose during treatment planning is clinically important. The objective of this study is to evaluate the accuracy of skin dose calculated by a commercial treatment planning system (TPS). We evaluated the accuracy of skin dose calculations by the anisotropic analytical algorithm (AAA) implemented in Varian Eclipse (V.11) system. Skin dose is calculated as mean dose to a contoured structure of 0.5 cm thickness from the surface. The EGSnrc Monte Carlo (MC) simulations are utilized for the evaluation. The 6, 10 and 15 MV photon beams investigated are from a Varian TrueBeam linear accelerator. The accuracy of the MC dose calculations was validated by phantom measurements with optically stimulated luminescence detectors. The calculation accuracy of patient skin doses is studied by using CT based radiotherapy treatment plans including 3D conformal, static gantry IMRT, and VMAT treatment techniques. Results show the Varian Eclipse system underestimates skin doses by up to 14% of prescription dose for the patients studied when external body contour starts at the patient's skin. The external body contour is used in a treatment planning system to calculate dose distributions. The calculation accuracy of skin dose with Eclipse can be considerably improved to within 4% of target dose by extending the external body contour by 1 to 2 cm from the patient's skin. Dose delivered to deeper target volumes or organs at risk are not affected. Although Eclipse treatment planning system has its limitations in predicting patient skin dose, this study shows the calculation accuracy can be considerably improved to an acceptable level by extending the external body contour without affecting the dose calculation accuracy to the treatment target and internal organs at risk. This is achieved by moving the calculation entry point away from the skin. |
format | Online Article Text |
id | pubmed-5849836 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | John Wiley and Sons Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-58498362018-04-02 A simple technique to improve calculated skin dose accuracy in a commercial treatment planning system Wang, Lilie Cmelak, Anthony J. Ding, George X. J Appl Clin Med Phys Radiation Oncology Physics Radiation dermatitis during radiotherapy is correlated with skin dose and is a common clinical problem for head and neck and thoracic cancer patients. Therefore, accurate prediction of skin dose during treatment planning is clinically important. The objective of this study is to evaluate the accuracy of skin dose calculated by a commercial treatment planning system (TPS). We evaluated the accuracy of skin dose calculations by the anisotropic analytical algorithm (AAA) implemented in Varian Eclipse (V.11) system. Skin dose is calculated as mean dose to a contoured structure of 0.5 cm thickness from the surface. The EGSnrc Monte Carlo (MC) simulations are utilized for the evaluation. The 6, 10 and 15 MV photon beams investigated are from a Varian TrueBeam linear accelerator. The accuracy of the MC dose calculations was validated by phantom measurements with optically stimulated luminescence detectors. The calculation accuracy of patient skin doses is studied by using CT based radiotherapy treatment plans including 3D conformal, static gantry IMRT, and VMAT treatment techniques. Results show the Varian Eclipse system underestimates skin doses by up to 14% of prescription dose for the patients studied when external body contour starts at the patient's skin. The external body contour is used in a treatment planning system to calculate dose distributions. The calculation accuracy of skin dose with Eclipse can be considerably improved to within 4% of target dose by extending the external body contour by 1 to 2 cm from the patient's skin. Dose delivered to deeper target volumes or organs at risk are not affected. Although Eclipse treatment planning system has its limitations in predicting patient skin dose, this study shows the calculation accuracy can be considerably improved to an acceptable level by extending the external body contour without affecting the dose calculation accuracy to the treatment target and internal organs at risk. This is achieved by moving the calculation entry point away from the skin. John Wiley and Sons Inc. 2018-02-06 /pmc/articles/PMC5849836/ /pubmed/29411506 http://dx.doi.org/10.1002/acm2.12275 Text en © 2018 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine. This is an open access article under the terms of the Creative Commons Attribution (http://creativecommons.org/licenses/by/4.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Radiation Oncology Physics Wang, Lilie Cmelak, Anthony J. Ding, George X. A simple technique to improve calculated skin dose accuracy in a commercial treatment planning system |
title | A simple technique to improve calculated skin dose accuracy in a commercial treatment planning system |
title_full | A simple technique to improve calculated skin dose accuracy in a commercial treatment planning system |
title_fullStr | A simple technique to improve calculated skin dose accuracy in a commercial treatment planning system |
title_full_unstemmed | A simple technique to improve calculated skin dose accuracy in a commercial treatment planning system |
title_short | A simple technique to improve calculated skin dose accuracy in a commercial treatment planning system |
title_sort | simple technique to improve calculated skin dose accuracy in a commercial treatment planning system |
topic | Radiation Oncology Physics |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5849836/ https://www.ncbi.nlm.nih.gov/pubmed/29411506 http://dx.doi.org/10.1002/acm2.12275 |
work_keys_str_mv | AT wanglilie asimpletechniquetoimprovecalculatedskindoseaccuracyinacommercialtreatmentplanningsystem AT cmelakanthonyj asimpletechniquetoimprovecalculatedskindoseaccuracyinacommercialtreatmentplanningsystem AT dinggeorgex asimpletechniquetoimprovecalculatedskindoseaccuracyinacommercialtreatmentplanningsystem AT wanglilie simpletechniquetoimprovecalculatedskindoseaccuracyinacommercialtreatmentplanningsystem AT cmelakanthonyj simpletechniquetoimprovecalculatedskindoseaccuracyinacommercialtreatmentplanningsystem AT dinggeorgex simpletechniquetoimprovecalculatedskindoseaccuracyinacommercialtreatmentplanningsystem |