Cargando…

Mitral Valve Anatomic Predictors of Hemodynamic Success With Transcatheter Mitral Valve Repair

BACKGROUND: Mitral regurgitation is a heterogeneous disease. Determining which patients derive optimal outcomes from transcatheter edge‐to‐edge mitral valve repair (TMVR) remains challenging. We sought to determine whether baseline mitral valve anatomic characteristics are predictive of left atrial...

Descripción completa

Detalles Bibliográficos
Autores principales: Thaden, Jeremy J., Malouf, Joseph F., Nkomo, Vuyisile T., Pislaru, Sorin V., Holmes, David R., Reeder, Guy S., Rihal, Charanjit S., Eleid, Mackram F.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5850157/
https://www.ncbi.nlm.nih.gov/pubmed/29331957
http://dx.doi.org/10.1161/JAHA.117.007315
_version_ 1783306179080880128
author Thaden, Jeremy J.
Malouf, Joseph F.
Nkomo, Vuyisile T.
Pislaru, Sorin V.
Holmes, David R.
Reeder, Guy S.
Rihal, Charanjit S.
Eleid, Mackram F.
author_facet Thaden, Jeremy J.
Malouf, Joseph F.
Nkomo, Vuyisile T.
Pislaru, Sorin V.
Holmes, David R.
Reeder, Guy S.
Rihal, Charanjit S.
Eleid, Mackram F.
author_sort Thaden, Jeremy J.
collection PubMed
description BACKGROUND: Mitral regurgitation is a heterogeneous disease. Determining which patients derive optimal outcomes from transcatheter edge‐to‐edge mitral valve repair (TMVR) remains challenging. We sought to determine whether baseline mitral valve anatomic characteristics are predictive of left atrial pressure (LAP) changes during TMVR with MitraClip. METHODS AND RESULTS: Consecutive patients with severe mitral regurgitation undergoing TMVR (n=112) underwent continuous intraprocedural LAP monitoring and retrospective echocardiographic analysis for specific mitral anatomic characteristics. Procedural success (optimal LAP reduction) was defined as ≥40% reduction in left atrial V‐wave pressure compared with baseline. Echocardiographic predictors of optimal LAP reduction and increased postprocedure mean diastolic gradient were evaluated. Mean age was 79±14 years, and 36 patients (32%) were women. Primary, mixed, and secondary mitral regurgitation were present in 78 patients (70%), 22 patients (20%), and 12 patients (10%), respectively. Baseline mean LAP and V‐wave were 22±6 and 38±13 mm Hg; after TMVR, these decreased to 19±5 and 27±10 mm Hg, respectively (P<0.0001 for both). Independent predictors of optimal LAP reduction were the presence of a flail scallop, mitral regurgitation localized to a single scallop, and high‐quality 3‐dimensional echocardiographic imaging. Independent predictors of elevated postprocedure mean diastolic gradient were elevated preprocedure mean diastolic gradient, mitral annular calcification, and implantation of multiple clips. CONCLUSIONS: Mitral valve pathoanatomic features, including a flail leaflet and single jet, are predictive of optimal LAP reduction with TMVR. High‐quality 3‐dimensional imaging may help select patients with the highest likelihood of optimal hemodynamic results with TMVR. These data expand current knowledge about patient selection for TMVR and deserve further study in larger cohorts.
format Online
Article
Text
id pubmed-5850157
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-58501572018-03-21 Mitral Valve Anatomic Predictors of Hemodynamic Success With Transcatheter Mitral Valve Repair Thaden, Jeremy J. Malouf, Joseph F. Nkomo, Vuyisile T. Pislaru, Sorin V. Holmes, David R. Reeder, Guy S. Rihal, Charanjit S. Eleid, Mackram F. J Am Heart Assoc Original Research BACKGROUND: Mitral regurgitation is a heterogeneous disease. Determining which patients derive optimal outcomes from transcatheter edge‐to‐edge mitral valve repair (TMVR) remains challenging. We sought to determine whether baseline mitral valve anatomic characteristics are predictive of left atrial pressure (LAP) changes during TMVR with MitraClip. METHODS AND RESULTS: Consecutive patients with severe mitral regurgitation undergoing TMVR (n=112) underwent continuous intraprocedural LAP monitoring and retrospective echocardiographic analysis for specific mitral anatomic characteristics. Procedural success (optimal LAP reduction) was defined as ≥40% reduction in left atrial V‐wave pressure compared with baseline. Echocardiographic predictors of optimal LAP reduction and increased postprocedure mean diastolic gradient were evaluated. Mean age was 79±14 years, and 36 patients (32%) were women. Primary, mixed, and secondary mitral regurgitation were present in 78 patients (70%), 22 patients (20%), and 12 patients (10%), respectively. Baseline mean LAP and V‐wave were 22±6 and 38±13 mm Hg; after TMVR, these decreased to 19±5 and 27±10 mm Hg, respectively (P<0.0001 for both). Independent predictors of optimal LAP reduction were the presence of a flail scallop, mitral regurgitation localized to a single scallop, and high‐quality 3‐dimensional echocardiographic imaging. Independent predictors of elevated postprocedure mean diastolic gradient were elevated preprocedure mean diastolic gradient, mitral annular calcification, and implantation of multiple clips. CONCLUSIONS: Mitral valve pathoanatomic features, including a flail leaflet and single jet, are predictive of optimal LAP reduction with TMVR. High‐quality 3‐dimensional imaging may help select patients with the highest likelihood of optimal hemodynamic results with TMVR. These data expand current knowledge about patient selection for TMVR and deserve further study in larger cohorts. John Wiley and Sons Inc. 2018-01-13 /pmc/articles/PMC5850157/ /pubmed/29331957 http://dx.doi.org/10.1161/JAHA.117.007315 Text en © 2018 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley. This is an open access article under the terms of the Creative Commons Attribution‐NonCommercial‐NoDerivs (http://creativecommons.org/licenses/by-nc-nd/4.0/) License, which permits use and distribution in any medium, provided the original work is properly cited, the use is non‐commercial and no modifications or adaptations are made.
spellingShingle Original Research
Thaden, Jeremy J.
Malouf, Joseph F.
Nkomo, Vuyisile T.
Pislaru, Sorin V.
Holmes, David R.
Reeder, Guy S.
Rihal, Charanjit S.
Eleid, Mackram F.
Mitral Valve Anatomic Predictors of Hemodynamic Success With Transcatheter Mitral Valve Repair
title Mitral Valve Anatomic Predictors of Hemodynamic Success With Transcatheter Mitral Valve Repair
title_full Mitral Valve Anatomic Predictors of Hemodynamic Success With Transcatheter Mitral Valve Repair
title_fullStr Mitral Valve Anatomic Predictors of Hemodynamic Success With Transcatheter Mitral Valve Repair
title_full_unstemmed Mitral Valve Anatomic Predictors of Hemodynamic Success With Transcatheter Mitral Valve Repair
title_short Mitral Valve Anatomic Predictors of Hemodynamic Success With Transcatheter Mitral Valve Repair
title_sort mitral valve anatomic predictors of hemodynamic success with transcatheter mitral valve repair
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5850157/
https://www.ncbi.nlm.nih.gov/pubmed/29331957
http://dx.doi.org/10.1161/JAHA.117.007315
work_keys_str_mv AT thadenjeremyj mitralvalveanatomicpredictorsofhemodynamicsuccesswithtranscathetermitralvalverepair
AT maloufjosephf mitralvalveanatomicpredictorsofhemodynamicsuccesswithtranscathetermitralvalverepair
AT nkomovuyisilet mitralvalveanatomicpredictorsofhemodynamicsuccesswithtranscathetermitralvalverepair
AT pislarusorinv mitralvalveanatomicpredictorsofhemodynamicsuccesswithtranscathetermitralvalverepair
AT holmesdavidr mitralvalveanatomicpredictorsofhemodynamicsuccesswithtranscathetermitralvalverepair
AT reederguys mitralvalveanatomicpredictorsofhemodynamicsuccesswithtranscathetermitralvalverepair
AT rihalcharanjits mitralvalveanatomicpredictorsofhemodynamicsuccesswithtranscathetermitralvalverepair
AT eleidmackramf mitralvalveanatomicpredictorsofhemodynamicsuccesswithtranscathetermitralvalverepair