Cargando…
Quantitating the Transfer of the HTLV-1 p8 Protein Between T-Cells by Flow Cytometry
The Human T-cell leukemia virus type 1 (HTLV-1)-encoded accessory protein p8 is cleaved from the precursor protein p12 encoded by the HTLV-1 open reading frame I. Both p12 and p8 are thought to contribute to efficient viral persistence. Mechanistically, p8 induces T-cell conjugates and cellular cond...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Frontiers Media S.A.
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5850991/ https://www.ncbi.nlm.nih.gov/pubmed/29563906 http://dx.doi.org/10.3389/fmicb.2018.00400 |
_version_ | 1783306316964429824 |
---|---|
author | Donhauser, Norbert Heym, Stefanie Thoma-Kress, Andrea K. |
author_facet | Donhauser, Norbert Heym, Stefanie Thoma-Kress, Andrea K. |
author_sort | Donhauser, Norbert |
collection | PubMed |
description | The Human T-cell leukemia virus type 1 (HTLV-1)-encoded accessory protein p8 is cleaved from the precursor protein p12 encoded by the HTLV-1 open reading frame I. Both p12 and p8 are thought to contribute to efficient viral persistence. Mechanistically, p8 induces T-cell conjugates and cellular conduits. The latter are considered to facilitate transfer of p8 to target cells and virus transmission. Transfer of p8 between p8-expressing T-cells and recipient cells has been analyzed by immunofluorescence and live imaging. However, automatic quantitation of p8-transfer between cells has not been studied yet. Here we developed a novel method allowing time saving quantitation of p8 transfer between cells by flow cytometry. After establishing a protocol for the detection of intracellular p8 by flow cytometry and validation of p8 protein expression by western blot and immunofluorescence, we set up a co-culture assay between p8-expressing donor Jurkat T-cells and recipient Jurkat T-cells that had been prestained with a well-retained live cell dye. Upon quantitating the amount of p8 positive recipient cells with regard to the percentage of p8 expressing donor cells, time course experiments confirmed that p8 is rapidly transferred between Jurkat T-cells. We found that p8 enters approximately 5% of recipient T-cells immediately upon co-culture for 5 min. Prolonged co-culture for up to 24 h revealed an increase of relative p8 transfer to approximately 23% of the recipient cells. Immunofluorescence analysis of co-culture experiments and manual quantitation of p8 expression in fluorescence images confirmed the validity of the flow cytometry based assay. Application of the new assay revealed that manipulation of actin polymerization significantly decreased p8 transfer between Jurkat T-cells suggesting an important role of actin dynamics contributing to p8 transfer. Further, transfer of p8 to co-cultured T-cells varies between different donor cell types since p8 transfer could hardly been detected in co-cultures of 293T donor cells with Jurkat acceptor cells. In summary, our novel assay allows automatic and rapid quantitation of p8 transfer to target cells and might thus contribute to a better understanding of cellular processes and dynamics regulating p8 transfer and HTLV-1 transmission. |
format | Online Article Text |
id | pubmed-5850991 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Frontiers Media S.A. |
record_format | MEDLINE/PubMed |
spelling | pubmed-58509912018-03-21 Quantitating the Transfer of the HTLV-1 p8 Protein Between T-Cells by Flow Cytometry Donhauser, Norbert Heym, Stefanie Thoma-Kress, Andrea K. Front Microbiol Microbiology The Human T-cell leukemia virus type 1 (HTLV-1)-encoded accessory protein p8 is cleaved from the precursor protein p12 encoded by the HTLV-1 open reading frame I. Both p12 and p8 are thought to contribute to efficient viral persistence. Mechanistically, p8 induces T-cell conjugates and cellular conduits. The latter are considered to facilitate transfer of p8 to target cells and virus transmission. Transfer of p8 between p8-expressing T-cells and recipient cells has been analyzed by immunofluorescence and live imaging. However, automatic quantitation of p8-transfer between cells has not been studied yet. Here we developed a novel method allowing time saving quantitation of p8 transfer between cells by flow cytometry. After establishing a protocol for the detection of intracellular p8 by flow cytometry and validation of p8 protein expression by western blot and immunofluorescence, we set up a co-culture assay between p8-expressing donor Jurkat T-cells and recipient Jurkat T-cells that had been prestained with a well-retained live cell dye. Upon quantitating the amount of p8 positive recipient cells with regard to the percentage of p8 expressing donor cells, time course experiments confirmed that p8 is rapidly transferred between Jurkat T-cells. We found that p8 enters approximately 5% of recipient T-cells immediately upon co-culture for 5 min. Prolonged co-culture for up to 24 h revealed an increase of relative p8 transfer to approximately 23% of the recipient cells. Immunofluorescence analysis of co-culture experiments and manual quantitation of p8 expression in fluorescence images confirmed the validity of the flow cytometry based assay. Application of the new assay revealed that manipulation of actin polymerization significantly decreased p8 transfer between Jurkat T-cells suggesting an important role of actin dynamics contributing to p8 transfer. Further, transfer of p8 to co-cultured T-cells varies between different donor cell types since p8 transfer could hardly been detected in co-cultures of 293T donor cells with Jurkat acceptor cells. In summary, our novel assay allows automatic and rapid quantitation of p8 transfer to target cells and might thus contribute to a better understanding of cellular processes and dynamics regulating p8 transfer and HTLV-1 transmission. Frontiers Media S.A. 2018-03-07 /pmc/articles/PMC5850991/ /pubmed/29563906 http://dx.doi.org/10.3389/fmicb.2018.00400 Text en Copyright © 2018 Donhauser, Heym and Thoma-Kress. http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms. |
spellingShingle | Microbiology Donhauser, Norbert Heym, Stefanie Thoma-Kress, Andrea K. Quantitating the Transfer of the HTLV-1 p8 Protein Between T-Cells by Flow Cytometry |
title | Quantitating the Transfer of the HTLV-1 p8 Protein Between T-Cells by Flow Cytometry |
title_full | Quantitating the Transfer of the HTLV-1 p8 Protein Between T-Cells by Flow Cytometry |
title_fullStr | Quantitating the Transfer of the HTLV-1 p8 Protein Between T-Cells by Flow Cytometry |
title_full_unstemmed | Quantitating the Transfer of the HTLV-1 p8 Protein Between T-Cells by Flow Cytometry |
title_short | Quantitating the Transfer of the HTLV-1 p8 Protein Between T-Cells by Flow Cytometry |
title_sort | quantitating the transfer of the htlv-1 p8 protein between t-cells by flow cytometry |
topic | Microbiology |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5850991/ https://www.ncbi.nlm.nih.gov/pubmed/29563906 http://dx.doi.org/10.3389/fmicb.2018.00400 |
work_keys_str_mv | AT donhausernorbert quantitatingthetransferofthehtlv1p8proteinbetweentcellsbyflowcytometry AT heymstefanie quantitatingthetransferofthehtlv1p8proteinbetweentcellsbyflowcytometry AT thomakressandreak quantitatingthetransferofthehtlv1p8proteinbetweentcellsbyflowcytometry |