Cargando…

Comparison of two different combined test strips with fluorescent microspheres or colored microspheres as tracers for rotavirus and adenovirus detection

BACKGROUND: Rotavirus (RV) and enteric adenovirus (AdV) mainly cause infantile infectious gastroenteritis. Several separate test methods for the detection of RV or AdV are currently available, but few tests are able to simultaneously detect both RV and AdV viruses, especially in primary medical inst...

Descripción completa

Detalles Bibliográficos
Autores principales: Jiang, Na, Shi, Lei, Lin, Jieping, Zhang, Lifang, Peng, Yanxia, Sheng, Huiying, Wu, Ping, Pan, Qingjun
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5851252/
https://www.ncbi.nlm.nih.gov/pubmed/29534739
http://dx.doi.org/10.1186/s12985-018-0951-5
_version_ 1783306360315707392
author Jiang, Na
Shi, Lei
Lin, Jieping
Zhang, Lifang
Peng, Yanxia
Sheng, Huiying
Wu, Ping
Pan, Qingjun
author_facet Jiang, Na
Shi, Lei
Lin, Jieping
Zhang, Lifang
Peng, Yanxia
Sheng, Huiying
Wu, Ping
Pan, Qingjun
author_sort Jiang, Na
collection PubMed
description BACKGROUND: Rotavirus (RV) and enteric adenovirus (AdV) mainly cause infantile infectious gastroenteritis. Several separate test methods for the detection of RV or AdV are currently available, but few tests are able to simultaneously detect both RV and AdV viruses, especially in primary medical institutions. METHODS: The present study was mainly designed to compare the performance of two combined test strips for the detection of RV and AdV: a rotavirus–adenovirus strip with fluorescent microspheres for tracers (FMT); and the CerTest rotavirus–adenovirus blister strip with colored microspheres for tracers (CMT). To test the strips cultures of RV, AdV and from other enteric pathogens were used, in addition to 350 stool specimens from 45 symptomatic patients with gastrointestinal infections. RESULTS: Detection thresholds for RV and AdV cultures using serial dilutions showed that the sensitivity of FMT was significantly higher than that of CMT (both P < 0.05). Specificity evaluation demonstrated that with culture mixtures of Coxsackie (A16), ECHO (type30), and entero- (EV71) viruses there was no detection of cross reaction using the two test strips, i.e., all the results were negative. With regard to the detection of RV in 350 clinical specimens, the total coincidence rate was 92.9%, the positive coincidence rate was 98.2%, and the negative coincidence rate was 90.8%. With regard to AdV detection, the total coincidence rate was 95.4%, the positive coincidence rate was 95.2%, and the negative coincidence rate was 95.5%. CONCLUSIONS: FMT performed better than CMT with regard to the combined detection of RV and AdV.
format Online
Article
Text
id pubmed-5851252
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-58512522018-03-21 Comparison of two different combined test strips with fluorescent microspheres or colored microspheres as tracers for rotavirus and adenovirus detection Jiang, Na Shi, Lei Lin, Jieping Zhang, Lifang Peng, Yanxia Sheng, Huiying Wu, Ping Pan, Qingjun Virol J Research BACKGROUND: Rotavirus (RV) and enteric adenovirus (AdV) mainly cause infantile infectious gastroenteritis. Several separate test methods for the detection of RV or AdV are currently available, but few tests are able to simultaneously detect both RV and AdV viruses, especially in primary medical institutions. METHODS: The present study was mainly designed to compare the performance of two combined test strips for the detection of RV and AdV: a rotavirus–adenovirus strip with fluorescent microspheres for tracers (FMT); and the CerTest rotavirus–adenovirus blister strip with colored microspheres for tracers (CMT). To test the strips cultures of RV, AdV and from other enteric pathogens were used, in addition to 350 stool specimens from 45 symptomatic patients with gastrointestinal infections. RESULTS: Detection thresholds for RV and AdV cultures using serial dilutions showed that the sensitivity of FMT was significantly higher than that of CMT (both P < 0.05). Specificity evaluation demonstrated that with culture mixtures of Coxsackie (A16), ECHO (type30), and entero- (EV71) viruses there was no detection of cross reaction using the two test strips, i.e., all the results were negative. With regard to the detection of RV in 350 clinical specimens, the total coincidence rate was 92.9%, the positive coincidence rate was 98.2%, and the negative coincidence rate was 90.8%. With regard to AdV detection, the total coincidence rate was 95.4%, the positive coincidence rate was 95.2%, and the negative coincidence rate was 95.5%. CONCLUSIONS: FMT performed better than CMT with regard to the combined detection of RV and AdV. BioMed Central 2018-03-13 /pmc/articles/PMC5851252/ /pubmed/29534739 http://dx.doi.org/10.1186/s12985-018-0951-5 Text en © The Author(s). 2018 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research
Jiang, Na
Shi, Lei
Lin, Jieping
Zhang, Lifang
Peng, Yanxia
Sheng, Huiying
Wu, Ping
Pan, Qingjun
Comparison of two different combined test strips with fluorescent microspheres or colored microspheres as tracers for rotavirus and adenovirus detection
title Comparison of two different combined test strips with fluorescent microspheres or colored microspheres as tracers for rotavirus and adenovirus detection
title_full Comparison of two different combined test strips with fluorescent microspheres or colored microspheres as tracers for rotavirus and adenovirus detection
title_fullStr Comparison of two different combined test strips with fluorescent microspheres or colored microspheres as tracers for rotavirus and adenovirus detection
title_full_unstemmed Comparison of two different combined test strips with fluorescent microspheres or colored microspheres as tracers for rotavirus and adenovirus detection
title_short Comparison of two different combined test strips with fluorescent microspheres or colored microspheres as tracers for rotavirus and adenovirus detection
title_sort comparison of two different combined test strips with fluorescent microspheres or colored microspheres as tracers for rotavirus and adenovirus detection
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5851252/
https://www.ncbi.nlm.nih.gov/pubmed/29534739
http://dx.doi.org/10.1186/s12985-018-0951-5
work_keys_str_mv AT jiangna comparisonoftwodifferentcombinedteststripswithfluorescentmicrospheresorcoloredmicrospheresastracersforrotavirusandadenovirusdetection
AT shilei comparisonoftwodifferentcombinedteststripswithfluorescentmicrospheresorcoloredmicrospheresastracersforrotavirusandadenovirusdetection
AT linjieping comparisonoftwodifferentcombinedteststripswithfluorescentmicrospheresorcoloredmicrospheresastracersforrotavirusandadenovirusdetection
AT zhanglifang comparisonoftwodifferentcombinedteststripswithfluorescentmicrospheresorcoloredmicrospheresastracersforrotavirusandadenovirusdetection
AT pengyanxia comparisonoftwodifferentcombinedteststripswithfluorescentmicrospheresorcoloredmicrospheresastracersforrotavirusandadenovirusdetection
AT shenghuiying comparisonoftwodifferentcombinedteststripswithfluorescentmicrospheresorcoloredmicrospheresastracersforrotavirusandadenovirusdetection
AT wuping comparisonoftwodifferentcombinedteststripswithfluorescentmicrospheresorcoloredmicrospheresastracersforrotavirusandadenovirusdetection
AT panqingjun comparisonoftwodifferentcombinedteststripswithfluorescentmicrospheresorcoloredmicrospheresastracersforrotavirusandadenovirusdetection