Calcium Chloride and Calcium Gluconate in Neonatal Parenteral Nutrition Solutions without Cysteine: Compatibility Studies Using Laser Light Obscuration Methodology

There are no compatibility studies for neonatal parenteral nutrition solutions without cysteine containing calcium chloride or calcium gluconate using light obscuration as recommended by the United States Pharmacopeia (USP). The purpose of this study was to do compatibility testing for solutions con...

Descripción completa

Detalles Bibliográficos
Autores principales: Huston, Robert K., Christensen, J. Mark, Alshahrani, Sultan M., Mohamed, Sumeia M., Heisel, Carl F.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5852784/
https://www.ncbi.nlm.nih.gov/pubmed/29443921
http://dx.doi.org/10.3390/nu10020208
_version_ 1783306634092609536
author Huston, Robert K.
Christensen, J. Mark
Alshahrani, Sultan M.
Mohamed, Sumeia M.
Heisel, Carl F.
author_facet Huston, Robert K.
Christensen, J. Mark
Alshahrani, Sultan M.
Mohamed, Sumeia M.
Heisel, Carl F.
author_sort Huston, Robert K.
collection PubMed
description There are no compatibility studies for neonatal parenteral nutrition solutions without cysteine containing calcium chloride or calcium gluconate using light obscuration as recommended by the United States Pharmacopeia (USP). The purpose of this study was to do compatibility testing for solutions containing calcium chloride and calcium gluconate without cysteine. Solutions of TrophAmine and Premasol (2.5% amino acids), containing calcium chloride or calcium gluconate were compounded without cysteine. Solutions were analyzed for particle counts using light obscuration. Maximum concentrations tested were 15 mmol/L of calcium and 12.5 mmol/L of phosphate. If the average particle count of three replicates exceeded USP guidelines, the solution was determined to be incompatible. This study found that 12.5 and 10 mmol/L of calcium and phosphate, respectively, are compatible in neonatal parenteral nutrition solutions compounded with 2.5% amino acids of either TrophAmine or Premasol. There did not appear to be significant differences in compatibility for solutions containing TrophAmine or Premasol when solutions were compounded with either CaCl(2) or CaGlu-Pl. This study presents data in order to evaluate options for adding calcium and phosphate to neonatal parenteral nutrition solutions during shortages of calcium and cysteine.
format Online
Article
Text
id pubmed-5852784
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-58527842018-03-19 Calcium Chloride and Calcium Gluconate in Neonatal Parenteral Nutrition Solutions without Cysteine: Compatibility Studies Using Laser Light Obscuration Methodology Huston, Robert K. Christensen, J. Mark Alshahrani, Sultan M. Mohamed, Sumeia M. Heisel, Carl F. Nutrients Article There are no compatibility studies for neonatal parenteral nutrition solutions without cysteine containing calcium chloride or calcium gluconate using light obscuration as recommended by the United States Pharmacopeia (USP). The purpose of this study was to do compatibility testing for solutions containing calcium chloride and calcium gluconate without cysteine. Solutions of TrophAmine and Premasol (2.5% amino acids), containing calcium chloride or calcium gluconate were compounded without cysteine. Solutions were analyzed for particle counts using light obscuration. Maximum concentrations tested were 15 mmol/L of calcium and 12.5 mmol/L of phosphate. If the average particle count of three replicates exceeded USP guidelines, the solution was determined to be incompatible. This study found that 12.5 and 10 mmol/L of calcium and phosphate, respectively, are compatible in neonatal parenteral nutrition solutions compounded with 2.5% amino acids of either TrophAmine or Premasol. There did not appear to be significant differences in compatibility for solutions containing TrophAmine or Premasol when solutions were compounded with either CaCl(2) or CaGlu-Pl. This study presents data in order to evaluate options for adding calcium and phosphate to neonatal parenteral nutrition solutions during shortages of calcium and cysteine. MDPI 2018-02-14 /pmc/articles/PMC5852784/ /pubmed/29443921 http://dx.doi.org/10.3390/nu10020208 Text en © 2018 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Huston, Robert K.
Christensen, J. Mark
Alshahrani, Sultan M.
Mohamed, Sumeia M.
Heisel, Carl F.
Calcium Chloride and Calcium Gluconate in Neonatal Parenteral Nutrition Solutions without Cysteine: Compatibility Studies Using Laser Light Obscuration Methodology
title Calcium Chloride and Calcium Gluconate in Neonatal Parenteral Nutrition Solutions without Cysteine: Compatibility Studies Using Laser Light Obscuration Methodology
title_full Calcium Chloride and Calcium Gluconate in Neonatal Parenteral Nutrition Solutions without Cysteine: Compatibility Studies Using Laser Light Obscuration Methodology
title_fullStr Calcium Chloride and Calcium Gluconate in Neonatal Parenteral Nutrition Solutions without Cysteine: Compatibility Studies Using Laser Light Obscuration Methodology
title_full_unstemmed Calcium Chloride and Calcium Gluconate in Neonatal Parenteral Nutrition Solutions without Cysteine: Compatibility Studies Using Laser Light Obscuration Methodology
title_short Calcium Chloride and Calcium Gluconate in Neonatal Parenteral Nutrition Solutions without Cysteine: Compatibility Studies Using Laser Light Obscuration Methodology
title_sort calcium chloride and calcium gluconate in neonatal parenteral nutrition solutions without cysteine: compatibility studies using laser light obscuration methodology
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5852784/
https://www.ncbi.nlm.nih.gov/pubmed/29443921
http://dx.doi.org/10.3390/nu10020208
work_keys_str_mv AT hustonrobertk calciumchlorideandcalciumgluconateinneonatalparenteralnutritionsolutionswithoutcysteinecompatibilitystudiesusinglaserlightobscurationmethodology
AT christensenjmark calciumchlorideandcalciumgluconateinneonatalparenteralnutritionsolutionswithoutcysteinecompatibilitystudiesusinglaserlightobscurationmethodology
AT alshahranisultanm calciumchlorideandcalciumgluconateinneonatalparenteralnutritionsolutionswithoutcysteinecompatibilitystudiesusinglaserlightobscurationmethodology
AT mohamedsumeiam calciumchlorideandcalciumgluconateinneonatalparenteralnutritionsolutionswithoutcysteinecompatibilitystudiesusinglaserlightobscurationmethodology
AT heiselcarlf calciumchlorideandcalciumgluconateinneonatalparenteralnutritionsolutionswithoutcysteinecompatibilitystudiesusinglaserlightobscurationmethodology