Factors affecting basket catheter detection of real and phantom rotors in the atria: A computational study
Anatomically based procedures to ablate atrial fibrillation (AF) are often successful in terminating paroxysmal AF. However, the ability to terminate persistent AF remains disappointing. New mechanistic approaches use multiple-electrode basket catheter mapping to localize and target AF drivers in th...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5854439/ https://www.ncbi.nlm.nih.gov/pubmed/29505583 http://dx.doi.org/10.1371/journal.pcbi.1006017 |
_version_ | 1783306917906481152 |
---|---|
author | Martinez-Mateu, Laura Romero, Lucia Ferrer-Albero, Ana Sebastian, Rafael Rodríguez Matas, José F. Jalife, José Berenfeld, Omer Saiz, Javier |
author_facet | Martinez-Mateu, Laura Romero, Lucia Ferrer-Albero, Ana Sebastian, Rafael Rodríguez Matas, José F. Jalife, José Berenfeld, Omer Saiz, Javier |
author_sort | Martinez-Mateu, Laura |
collection | PubMed |
description | Anatomically based procedures to ablate atrial fibrillation (AF) are often successful in terminating paroxysmal AF. However, the ability to terminate persistent AF remains disappointing. New mechanistic approaches use multiple-electrode basket catheter mapping to localize and target AF drivers in the form of rotors but significant concerns remain about their accuracy. We aimed to evaluate how electrode-endocardium distance, far-field sources and inter-electrode distance affect the accuracy of localizing rotors. Sustained rotor activation of the atria was simulated numerically and mapped using a virtual basket catheter with varying electrode densities placed at different positions within the atrial cavity. Unipolar electrograms were calculated on the entire endocardial surface and at each of the electrodes. Rotors were tracked on the interpolated basket phase maps and compared with the respective atrial voltage and endocardial phase maps, which served as references. Rotor detection by the basket maps varied between 35–94% of the simulation time, depending on the basket’s position and the electrode-to-endocardial wall distance. However, two different types of phantom rotors appeared also on the basket maps. The first type was due to the far-field sources and the second type was due to interpolation between the electrodes; increasing electrode density decreased the incidence of the second but not the first type of phantom rotors. In the simulations study, basket catheter-based phase mapping detected rotors even when the basket was not in full contact with the endocardial wall, but always generated a number of phantom rotors in the presence of only a single real rotor, which would be the desired ablation target. Phantom rotors may mislead and contribute to failure in AF ablation procedures. |
format | Online Article Text |
id | pubmed-5854439 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-58544392018-03-28 Factors affecting basket catheter detection of real and phantom rotors in the atria: A computational study Martinez-Mateu, Laura Romero, Lucia Ferrer-Albero, Ana Sebastian, Rafael Rodríguez Matas, José F. Jalife, José Berenfeld, Omer Saiz, Javier PLoS Comput Biol Research Article Anatomically based procedures to ablate atrial fibrillation (AF) are often successful in terminating paroxysmal AF. However, the ability to terminate persistent AF remains disappointing. New mechanistic approaches use multiple-electrode basket catheter mapping to localize and target AF drivers in the form of rotors but significant concerns remain about their accuracy. We aimed to evaluate how electrode-endocardium distance, far-field sources and inter-electrode distance affect the accuracy of localizing rotors. Sustained rotor activation of the atria was simulated numerically and mapped using a virtual basket catheter with varying electrode densities placed at different positions within the atrial cavity. Unipolar electrograms were calculated on the entire endocardial surface and at each of the electrodes. Rotors were tracked on the interpolated basket phase maps and compared with the respective atrial voltage and endocardial phase maps, which served as references. Rotor detection by the basket maps varied between 35–94% of the simulation time, depending on the basket’s position and the electrode-to-endocardial wall distance. However, two different types of phantom rotors appeared also on the basket maps. The first type was due to the far-field sources and the second type was due to interpolation between the electrodes; increasing electrode density decreased the incidence of the second but not the first type of phantom rotors. In the simulations study, basket catheter-based phase mapping detected rotors even when the basket was not in full contact with the endocardial wall, but always generated a number of phantom rotors in the presence of only a single real rotor, which would be the desired ablation target. Phantom rotors may mislead and contribute to failure in AF ablation procedures. Public Library of Science 2018-03-05 /pmc/articles/PMC5854439/ /pubmed/29505583 http://dx.doi.org/10.1371/journal.pcbi.1006017 Text en © 2018 Martinez-Mateu et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Research Article Martinez-Mateu, Laura Romero, Lucia Ferrer-Albero, Ana Sebastian, Rafael Rodríguez Matas, José F. Jalife, José Berenfeld, Omer Saiz, Javier Factors affecting basket catheter detection of real and phantom rotors in the atria: A computational study |
title | Factors affecting basket catheter detection of real and phantom rotors in the atria: A computational study |
title_full | Factors affecting basket catheter detection of real and phantom rotors in the atria: A computational study |
title_fullStr | Factors affecting basket catheter detection of real and phantom rotors in the atria: A computational study |
title_full_unstemmed | Factors affecting basket catheter detection of real and phantom rotors in the atria: A computational study |
title_short | Factors affecting basket catheter detection of real and phantom rotors in the atria: A computational study |
title_sort | factors affecting basket catheter detection of real and phantom rotors in the atria: a computational study |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5854439/ https://www.ncbi.nlm.nih.gov/pubmed/29505583 http://dx.doi.org/10.1371/journal.pcbi.1006017 |
work_keys_str_mv | AT martinezmateulaura factorsaffectingbasketcatheterdetectionofrealandphantomrotorsintheatriaacomputationalstudy AT romerolucia factorsaffectingbasketcatheterdetectionofrealandphantomrotorsintheatriaacomputationalstudy AT ferreralberoana factorsaffectingbasketcatheterdetectionofrealandphantomrotorsintheatriaacomputationalstudy AT sebastianrafael factorsaffectingbasketcatheterdetectionofrealandphantomrotorsintheatriaacomputationalstudy AT rodriguezmatasjosef factorsaffectingbasketcatheterdetectionofrealandphantomrotorsintheatriaacomputationalstudy AT jalifejose factorsaffectingbasketcatheterdetectionofrealandphantomrotorsintheatriaacomputationalstudy AT berenfeldomer factorsaffectingbasketcatheterdetectionofrealandphantomrotorsintheatriaacomputationalstudy AT saizjavier factorsaffectingbasketcatheterdetectionofrealandphantomrotorsintheatriaacomputationalstudy |