Cargando…

Factors affecting basket catheter detection of real and phantom rotors in the atria: A computational study

Anatomically based procedures to ablate atrial fibrillation (AF) are often successful in terminating paroxysmal AF. However, the ability to terminate persistent AF remains disappointing. New mechanistic approaches use multiple-electrode basket catheter mapping to localize and target AF drivers in th...

Descripción completa

Detalles Bibliográficos
Autores principales: Martinez-Mateu, Laura, Romero, Lucia, Ferrer-Albero, Ana, Sebastian, Rafael, Rodríguez Matas, José F., Jalife, José, Berenfeld, Omer, Saiz, Javier
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5854439/
https://www.ncbi.nlm.nih.gov/pubmed/29505583
http://dx.doi.org/10.1371/journal.pcbi.1006017
_version_ 1783306917906481152
author Martinez-Mateu, Laura
Romero, Lucia
Ferrer-Albero, Ana
Sebastian, Rafael
Rodríguez Matas, José F.
Jalife, José
Berenfeld, Omer
Saiz, Javier
author_facet Martinez-Mateu, Laura
Romero, Lucia
Ferrer-Albero, Ana
Sebastian, Rafael
Rodríguez Matas, José F.
Jalife, José
Berenfeld, Omer
Saiz, Javier
author_sort Martinez-Mateu, Laura
collection PubMed
description Anatomically based procedures to ablate atrial fibrillation (AF) are often successful in terminating paroxysmal AF. However, the ability to terminate persistent AF remains disappointing. New mechanistic approaches use multiple-electrode basket catheter mapping to localize and target AF drivers in the form of rotors but significant concerns remain about their accuracy. We aimed to evaluate how electrode-endocardium distance, far-field sources and inter-electrode distance affect the accuracy of localizing rotors. Sustained rotor activation of the atria was simulated numerically and mapped using a virtual basket catheter with varying electrode densities placed at different positions within the atrial cavity. Unipolar electrograms were calculated on the entire endocardial surface and at each of the electrodes. Rotors were tracked on the interpolated basket phase maps and compared with the respective atrial voltage and endocardial phase maps, which served as references. Rotor detection by the basket maps varied between 35–94% of the simulation time, depending on the basket’s position and the electrode-to-endocardial wall distance. However, two different types of phantom rotors appeared also on the basket maps. The first type was due to the far-field sources and the second type was due to interpolation between the electrodes; increasing electrode density decreased the incidence of the second but not the first type of phantom rotors. In the simulations study, basket catheter-based phase mapping detected rotors even when the basket was not in full contact with the endocardial wall, but always generated a number of phantom rotors in the presence of only a single real rotor, which would be the desired ablation target. Phantom rotors may mislead and contribute to failure in AF ablation procedures.
format Online
Article
Text
id pubmed-5854439
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-58544392018-03-28 Factors affecting basket catheter detection of real and phantom rotors in the atria: A computational study Martinez-Mateu, Laura Romero, Lucia Ferrer-Albero, Ana Sebastian, Rafael Rodríguez Matas, José F. Jalife, José Berenfeld, Omer Saiz, Javier PLoS Comput Biol Research Article Anatomically based procedures to ablate atrial fibrillation (AF) are often successful in terminating paroxysmal AF. However, the ability to terminate persistent AF remains disappointing. New mechanistic approaches use multiple-electrode basket catheter mapping to localize and target AF drivers in the form of rotors but significant concerns remain about their accuracy. We aimed to evaluate how electrode-endocardium distance, far-field sources and inter-electrode distance affect the accuracy of localizing rotors. Sustained rotor activation of the atria was simulated numerically and mapped using a virtual basket catheter with varying electrode densities placed at different positions within the atrial cavity. Unipolar electrograms were calculated on the entire endocardial surface and at each of the electrodes. Rotors were tracked on the interpolated basket phase maps and compared with the respective atrial voltage and endocardial phase maps, which served as references. Rotor detection by the basket maps varied between 35–94% of the simulation time, depending on the basket’s position and the electrode-to-endocardial wall distance. However, two different types of phantom rotors appeared also on the basket maps. The first type was due to the far-field sources and the second type was due to interpolation between the electrodes; increasing electrode density decreased the incidence of the second but not the first type of phantom rotors. In the simulations study, basket catheter-based phase mapping detected rotors even when the basket was not in full contact with the endocardial wall, but always generated a number of phantom rotors in the presence of only a single real rotor, which would be the desired ablation target. Phantom rotors may mislead and contribute to failure in AF ablation procedures. Public Library of Science 2018-03-05 /pmc/articles/PMC5854439/ /pubmed/29505583 http://dx.doi.org/10.1371/journal.pcbi.1006017 Text en © 2018 Martinez-Mateu et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Martinez-Mateu, Laura
Romero, Lucia
Ferrer-Albero, Ana
Sebastian, Rafael
Rodríguez Matas, José F.
Jalife, José
Berenfeld, Omer
Saiz, Javier
Factors affecting basket catheter detection of real and phantom rotors in the atria: A computational study
title Factors affecting basket catheter detection of real and phantom rotors in the atria: A computational study
title_full Factors affecting basket catheter detection of real and phantom rotors in the atria: A computational study
title_fullStr Factors affecting basket catheter detection of real and phantom rotors in the atria: A computational study
title_full_unstemmed Factors affecting basket catheter detection of real and phantom rotors in the atria: A computational study
title_short Factors affecting basket catheter detection of real and phantom rotors in the atria: A computational study
title_sort factors affecting basket catheter detection of real and phantom rotors in the atria: a computational study
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5854439/
https://www.ncbi.nlm.nih.gov/pubmed/29505583
http://dx.doi.org/10.1371/journal.pcbi.1006017
work_keys_str_mv AT martinezmateulaura factorsaffectingbasketcatheterdetectionofrealandphantomrotorsintheatriaacomputationalstudy
AT romerolucia factorsaffectingbasketcatheterdetectionofrealandphantomrotorsintheatriaacomputationalstudy
AT ferreralberoana factorsaffectingbasketcatheterdetectionofrealandphantomrotorsintheatriaacomputationalstudy
AT sebastianrafael factorsaffectingbasketcatheterdetectionofrealandphantomrotorsintheatriaacomputationalstudy
AT rodriguezmatasjosef factorsaffectingbasketcatheterdetectionofrealandphantomrotorsintheatriaacomputationalstudy
AT jalifejose factorsaffectingbasketcatheterdetectionofrealandphantomrotorsintheatriaacomputationalstudy
AT berenfeldomer factorsaffectingbasketcatheterdetectionofrealandphantomrotorsintheatriaacomputationalstudy
AT saizjavier factorsaffectingbasketcatheterdetectionofrealandphantomrotorsintheatriaacomputationalstudy