Cargando…

An Improved Calibration Method for a Rotating 2D LIDAR System

This paper presents an improved calibration method of a rotating two-dimensional light detection and ranging (R2D-LIDAR) system, which can obtain the 3D scanning map of the surroundings. The proposed R2D-LIDAR system, composed of a 2D LIDAR and a rotating unit, is pervasively used in the field of ro...

Descripción completa

Detalles Bibliográficos
Autores principales: Zeng, Yadan, Yu, Heng, Dai, Houde, Song, Shuang, Lin, Mingqiang, Sun, Bo, Jiang, Wei, Meng, Max Q.-H.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5855012/
https://www.ncbi.nlm.nih.gov/pubmed/29414885
http://dx.doi.org/10.3390/s18020497
_version_ 1783307015322337280
author Zeng, Yadan
Yu, Heng
Dai, Houde
Song, Shuang
Lin, Mingqiang
Sun, Bo
Jiang, Wei
Meng, Max Q.-H.
author_facet Zeng, Yadan
Yu, Heng
Dai, Houde
Song, Shuang
Lin, Mingqiang
Sun, Bo
Jiang, Wei
Meng, Max Q.-H.
author_sort Zeng, Yadan
collection PubMed
description This paper presents an improved calibration method of a rotating two-dimensional light detection and ranging (R2D-LIDAR) system, which can obtain the 3D scanning map of the surroundings. The proposed R2D-LIDAR system, composed of a 2D LIDAR and a rotating unit, is pervasively used in the field of robotics owing to its low cost and dense scanning data. Nevertheless, the R2D-LIDAR system must be calibrated before building the geometric model because there are assembled deviation and abrasion between the 2D LIDAR and the rotating unit. Hence, the calibration procedures should contain both the adjustment between the two devices and the bias of 2D LIDAR itself. The main purpose of this work is to resolve the 2D LIDAR bias issue with a flat plane based on the Levenberg–Marquardt (LM) algorithm. Experimental results for the calibration of the R2D-LIDAR system prove the reliability of this strategy to accurately estimate sensor offsets with the error range from −15 mm to 15 mm for the performance of capturing scans.
format Online
Article
Text
id pubmed-5855012
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-58550122018-03-20 An Improved Calibration Method for a Rotating 2D LIDAR System Zeng, Yadan Yu, Heng Dai, Houde Song, Shuang Lin, Mingqiang Sun, Bo Jiang, Wei Meng, Max Q.-H. Sensors (Basel) Article This paper presents an improved calibration method of a rotating two-dimensional light detection and ranging (R2D-LIDAR) system, which can obtain the 3D scanning map of the surroundings. The proposed R2D-LIDAR system, composed of a 2D LIDAR and a rotating unit, is pervasively used in the field of robotics owing to its low cost and dense scanning data. Nevertheless, the R2D-LIDAR system must be calibrated before building the geometric model because there are assembled deviation and abrasion between the 2D LIDAR and the rotating unit. Hence, the calibration procedures should contain both the adjustment between the two devices and the bias of 2D LIDAR itself. The main purpose of this work is to resolve the 2D LIDAR bias issue with a flat plane based on the Levenberg–Marquardt (LM) algorithm. Experimental results for the calibration of the R2D-LIDAR system prove the reliability of this strategy to accurately estimate sensor offsets with the error range from −15 mm to 15 mm for the performance of capturing scans. MDPI 2018-02-07 /pmc/articles/PMC5855012/ /pubmed/29414885 http://dx.doi.org/10.3390/s18020497 Text en © 2018 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Zeng, Yadan
Yu, Heng
Dai, Houde
Song, Shuang
Lin, Mingqiang
Sun, Bo
Jiang, Wei
Meng, Max Q.-H.
An Improved Calibration Method for a Rotating 2D LIDAR System
title An Improved Calibration Method for a Rotating 2D LIDAR System
title_full An Improved Calibration Method for a Rotating 2D LIDAR System
title_fullStr An Improved Calibration Method for a Rotating 2D LIDAR System
title_full_unstemmed An Improved Calibration Method for a Rotating 2D LIDAR System
title_short An Improved Calibration Method for a Rotating 2D LIDAR System
title_sort improved calibration method for a rotating 2d lidar system
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5855012/
https://www.ncbi.nlm.nih.gov/pubmed/29414885
http://dx.doi.org/10.3390/s18020497
work_keys_str_mv AT zengyadan animprovedcalibrationmethodforarotating2dlidarsystem
AT yuheng animprovedcalibrationmethodforarotating2dlidarsystem
AT daihoude animprovedcalibrationmethodforarotating2dlidarsystem
AT songshuang animprovedcalibrationmethodforarotating2dlidarsystem
AT linmingqiang animprovedcalibrationmethodforarotating2dlidarsystem
AT sunbo animprovedcalibrationmethodforarotating2dlidarsystem
AT jiangwei animprovedcalibrationmethodforarotating2dlidarsystem
AT mengmaxqh animprovedcalibrationmethodforarotating2dlidarsystem
AT zengyadan improvedcalibrationmethodforarotating2dlidarsystem
AT yuheng improvedcalibrationmethodforarotating2dlidarsystem
AT daihoude improvedcalibrationmethodforarotating2dlidarsystem
AT songshuang improvedcalibrationmethodforarotating2dlidarsystem
AT linmingqiang improvedcalibrationmethodforarotating2dlidarsystem
AT sunbo improvedcalibrationmethodforarotating2dlidarsystem
AT jiangwei improvedcalibrationmethodforarotating2dlidarsystem
AT mengmaxqh improvedcalibrationmethodforarotating2dlidarsystem