Cargando…

Calibration of Elasto-Magnetic Sensors on In-Service Cable-Stayed Bridges for Stress Monitoring

The recent developments in measurement technology have led to the installation of efficient monitoring systems on many bridges and other structures all over the world. Nowadays, more and more structures have been built and instrumented with sensors. However, calibration and installation of sensors r...

Descripción completa

Detalles Bibliográficos
Autores principales: Cappello, Carlo, Zonta, Daniele, Ait Laasri, Hassan, Glisic, Branko, Wang, Ming
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5855026/
https://www.ncbi.nlm.nih.gov/pubmed/29401751
http://dx.doi.org/10.3390/s18020466
_version_ 1783307017162588160
author Cappello, Carlo
Zonta, Daniele
Ait Laasri, Hassan
Glisic, Branko
Wang, Ming
author_facet Cappello, Carlo
Zonta, Daniele
Ait Laasri, Hassan
Glisic, Branko
Wang, Ming
author_sort Cappello, Carlo
collection PubMed
description The recent developments in measurement technology have led to the installation of efficient monitoring systems on many bridges and other structures all over the world. Nowadays, more and more structures have been built and instrumented with sensors. However, calibration and installation of sensors remain challenging tasks. In this paper, we use a case study, Adige Bridge, in order to present a low-cost method for the calibration and installation of elasto-magnetic sensors on cable-stayed bridges. Elasto-magnetic sensors enable monitoring of cable stress. The sensor installation took place two years after the bridge construction. The calibration was conducted in two phases: one in the laboratory and the other one on site. In the laboratory, a sensor was built around a segment of cable that was identical to those of the cable-stayed bridge. Then, the sample was subjected to a defined tension force. The sensor response was compared with the applied load. Experimental results showed that the relationship between load and magnetic permeability does not depend on the sensor fabrication process except for an offset. The determination of this offset required in situ calibration after installation. In order to perform the in situ calibration without removing the cables from the bridge, vibration tests were carried out for the estimation of the cables’ tensions. At the end of the paper, we show and discuss one year of data from the elasto-magnetic sensors. Calibration results demonstrate the simplicity of the installation of these sensors on existing bridges and new structures.
format Online
Article
Text
id pubmed-5855026
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-58550262018-03-20 Calibration of Elasto-Magnetic Sensors on In-Service Cable-Stayed Bridges for Stress Monitoring Cappello, Carlo Zonta, Daniele Ait Laasri, Hassan Glisic, Branko Wang, Ming Sensors (Basel) Article The recent developments in measurement technology have led to the installation of efficient monitoring systems on many bridges and other structures all over the world. Nowadays, more and more structures have been built and instrumented with sensors. However, calibration and installation of sensors remain challenging tasks. In this paper, we use a case study, Adige Bridge, in order to present a low-cost method for the calibration and installation of elasto-magnetic sensors on cable-stayed bridges. Elasto-magnetic sensors enable monitoring of cable stress. The sensor installation took place two years after the bridge construction. The calibration was conducted in two phases: one in the laboratory and the other one on site. In the laboratory, a sensor was built around a segment of cable that was identical to those of the cable-stayed bridge. Then, the sample was subjected to a defined tension force. The sensor response was compared with the applied load. Experimental results showed that the relationship between load and magnetic permeability does not depend on the sensor fabrication process except for an offset. The determination of this offset required in situ calibration after installation. In order to perform the in situ calibration without removing the cables from the bridge, vibration tests were carried out for the estimation of the cables’ tensions. At the end of the paper, we show and discuss one year of data from the elasto-magnetic sensors. Calibration results demonstrate the simplicity of the installation of these sensors on existing bridges and new structures. MDPI 2018-02-05 /pmc/articles/PMC5855026/ /pubmed/29401751 http://dx.doi.org/10.3390/s18020466 Text en © 2018 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Cappello, Carlo
Zonta, Daniele
Ait Laasri, Hassan
Glisic, Branko
Wang, Ming
Calibration of Elasto-Magnetic Sensors on In-Service Cable-Stayed Bridges for Stress Monitoring
title Calibration of Elasto-Magnetic Sensors on In-Service Cable-Stayed Bridges for Stress Monitoring
title_full Calibration of Elasto-Magnetic Sensors on In-Service Cable-Stayed Bridges for Stress Monitoring
title_fullStr Calibration of Elasto-Magnetic Sensors on In-Service Cable-Stayed Bridges for Stress Monitoring
title_full_unstemmed Calibration of Elasto-Magnetic Sensors on In-Service Cable-Stayed Bridges for Stress Monitoring
title_short Calibration of Elasto-Magnetic Sensors on In-Service Cable-Stayed Bridges for Stress Monitoring
title_sort calibration of elasto-magnetic sensors on in-service cable-stayed bridges for stress monitoring
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5855026/
https://www.ncbi.nlm.nih.gov/pubmed/29401751
http://dx.doi.org/10.3390/s18020466
work_keys_str_mv AT cappellocarlo calibrationofelastomagneticsensorsoninservicecablestayedbridgesforstressmonitoring
AT zontadaniele calibrationofelastomagneticsensorsoninservicecablestayedbridgesforstressmonitoring
AT aitlaasrihassan calibrationofelastomagneticsensorsoninservicecablestayedbridgesforstressmonitoring
AT glisicbranko calibrationofelastomagneticsensorsoninservicecablestayedbridgesforstressmonitoring
AT wangming calibrationofelastomagneticsensorsoninservicecablestayedbridgesforstressmonitoring