Cargando…

Chemical Sensor Systems and Associated Algorithms for Fire Detection: A Review

Indoor fire detection using gas chemical sensing has been a subject of investigation since the early nineties. This approach leverages the fact that, for certain types of fire, chemical volatiles appear before smoke particles do. Hence, systems based on chemical sensing can provide faster fire alarm...

Descripción completa

Detalles Bibliográficos
Autores principales: Fonollosa, Jordi, Solórzano, Ana, Marco, Santiago
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5855033/
https://www.ncbi.nlm.nih.gov/pubmed/29439490
http://dx.doi.org/10.3390/s18020553
_version_ 1783307018802561024
author Fonollosa, Jordi
Solórzano, Ana
Marco, Santiago
author_facet Fonollosa, Jordi
Solórzano, Ana
Marco, Santiago
author_sort Fonollosa, Jordi
collection PubMed
description Indoor fire detection using gas chemical sensing has been a subject of investigation since the early nineties. This approach leverages the fact that, for certain types of fire, chemical volatiles appear before smoke particles do. Hence, systems based on chemical sensing can provide faster fire alarm responses than conventional smoke-based fire detectors. Moreover, since it is known that most casualties in fires are produced from toxic emissions rather than actual burns, gas-based fire detection could provide an additional level of safety to building occupants. In this line, since the 2000s, electrochemical cells for carbon monoxide sensing have been incorporated into fire detectors. Even systems relying exclusively on gas sensors have been explored as fire detectors. However, gas sensors respond to a large variety of volatiles beyond combustion products. As a result, chemical-based fire detectors require multivariate data processing techniques to ensure high sensitivity to fires and false alarm immunity. In this paper, we the survey toxic emissions produced in fires and defined standards for fire detection systems. We also review the state of the art of chemical sensor systems for fire detection and the associated signal and data processing algorithms. We also examine the experimental protocols used for the validation of the different approaches, as the complexity of the test measurements also impacts on reported sensitivity and specificity measures. All in all, further research and extensive test under different fire and nuisance scenarios are still required before gas-based fire detectors penetrate largely into the market. Nevertheless, the use of dynamic features and multivariate models that exploit sensor correlations seems imperative.
format Online
Article
Text
id pubmed-5855033
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-58550332018-03-20 Chemical Sensor Systems and Associated Algorithms for Fire Detection: A Review Fonollosa, Jordi Solórzano, Ana Marco, Santiago Sensors (Basel) Review Indoor fire detection using gas chemical sensing has been a subject of investigation since the early nineties. This approach leverages the fact that, for certain types of fire, chemical volatiles appear before smoke particles do. Hence, systems based on chemical sensing can provide faster fire alarm responses than conventional smoke-based fire detectors. Moreover, since it is known that most casualties in fires are produced from toxic emissions rather than actual burns, gas-based fire detection could provide an additional level of safety to building occupants. In this line, since the 2000s, electrochemical cells for carbon monoxide sensing have been incorporated into fire detectors. Even systems relying exclusively on gas sensors have been explored as fire detectors. However, gas sensors respond to a large variety of volatiles beyond combustion products. As a result, chemical-based fire detectors require multivariate data processing techniques to ensure high sensitivity to fires and false alarm immunity. In this paper, we the survey toxic emissions produced in fires and defined standards for fire detection systems. We also review the state of the art of chemical sensor systems for fire detection and the associated signal and data processing algorithms. We also examine the experimental protocols used for the validation of the different approaches, as the complexity of the test measurements also impacts on reported sensitivity and specificity measures. All in all, further research and extensive test under different fire and nuisance scenarios are still required before gas-based fire detectors penetrate largely into the market. Nevertheless, the use of dynamic features and multivariate models that exploit sensor correlations seems imperative. MDPI 2018-02-11 /pmc/articles/PMC5855033/ /pubmed/29439490 http://dx.doi.org/10.3390/s18020553 Text en © 2018 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Review
Fonollosa, Jordi
Solórzano, Ana
Marco, Santiago
Chemical Sensor Systems and Associated Algorithms for Fire Detection: A Review
title Chemical Sensor Systems and Associated Algorithms for Fire Detection: A Review
title_full Chemical Sensor Systems and Associated Algorithms for Fire Detection: A Review
title_fullStr Chemical Sensor Systems and Associated Algorithms for Fire Detection: A Review
title_full_unstemmed Chemical Sensor Systems and Associated Algorithms for Fire Detection: A Review
title_short Chemical Sensor Systems and Associated Algorithms for Fire Detection: A Review
title_sort chemical sensor systems and associated algorithms for fire detection: a review
topic Review
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5855033/
https://www.ncbi.nlm.nih.gov/pubmed/29439490
http://dx.doi.org/10.3390/s18020553
work_keys_str_mv AT fonollosajordi chemicalsensorsystemsandassociatedalgorithmsforfiredetectionareview
AT solorzanoana chemicalsensorsystemsandassociatedalgorithmsforfiredetectionareview
AT marcosantiago chemicalsensorsystemsandassociatedalgorithmsforfiredetectionareview