Cargando…
Compact Surface Plasmon Resonance System with Au/Si Schottky Barrier
Ethanol concentration was quantified by the use of a compact surface plasmon resonance (SPR) system, which electrically detects hot electrons via a Schottky barrier. Although it is well known that SPR can be used as bio/chemical sensors, implementation is not necessarily practical, due to the size a...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5855120/ https://www.ncbi.nlm.nih.gov/pubmed/29385726 http://dx.doi.org/10.3390/s18020399 |
_version_ | 1783307034027884544 |
---|---|
author | Tsukagoshi, Takuya Kuroda, Yuta Noda, Kentaro Binh-Khiem, Nguyen Kan, Tetsuo Shimoyama, Isao |
author_facet | Tsukagoshi, Takuya Kuroda, Yuta Noda, Kentaro Binh-Khiem, Nguyen Kan, Tetsuo Shimoyama, Isao |
author_sort | Tsukagoshi, Takuya |
collection | PubMed |
description | Ethanol concentration was quantified by the use of a compact surface plasmon resonance (SPR) system, which electrically detects hot electrons via a Schottky barrier. Although it is well known that SPR can be used as bio/chemical sensors, implementation is not necessarily practical, due to the size and cost impediments associated with a system with variable wavelength or angle of incidence. However, scanning capability is not a prerequisite if the objective is to use SPR in a sensor. It is possible to build a small, inexpensive SPR sensor if the optics have no moving parts and a Schottky barrier is used for electrical current detection in place of a photodetector. This article reports on the design and performance of such a novel SPR sensor, and its application for quantifying ethanol concentration. As the concentration of ethanol is increased, the change in the angle dependence of the SPR current is observed. This change can be understood as a superposition of contributions of SPR coupled with the +3rd- and −3rd-order diffraction. Moreover, real-time monitoring of ethanol concentration was demonstrated using the proposed SPR system. |
format | Online Article Text |
id | pubmed-5855120 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-58551202018-03-20 Compact Surface Plasmon Resonance System with Au/Si Schottky Barrier Tsukagoshi, Takuya Kuroda, Yuta Noda, Kentaro Binh-Khiem, Nguyen Kan, Tetsuo Shimoyama, Isao Sensors (Basel) Article Ethanol concentration was quantified by the use of a compact surface plasmon resonance (SPR) system, which electrically detects hot electrons via a Schottky barrier. Although it is well known that SPR can be used as bio/chemical sensors, implementation is not necessarily practical, due to the size and cost impediments associated with a system with variable wavelength or angle of incidence. However, scanning capability is not a prerequisite if the objective is to use SPR in a sensor. It is possible to build a small, inexpensive SPR sensor if the optics have no moving parts and a Schottky barrier is used for electrical current detection in place of a photodetector. This article reports on the design and performance of such a novel SPR sensor, and its application for quantifying ethanol concentration. As the concentration of ethanol is increased, the change in the angle dependence of the SPR current is observed. This change can be understood as a superposition of contributions of SPR coupled with the +3rd- and −3rd-order diffraction. Moreover, real-time monitoring of ethanol concentration was demonstrated using the proposed SPR system. MDPI 2018-01-30 /pmc/articles/PMC5855120/ /pubmed/29385726 http://dx.doi.org/10.3390/s18020399 Text en © 2018 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Tsukagoshi, Takuya Kuroda, Yuta Noda, Kentaro Binh-Khiem, Nguyen Kan, Tetsuo Shimoyama, Isao Compact Surface Plasmon Resonance System with Au/Si Schottky Barrier |
title | Compact Surface Plasmon Resonance System with Au/Si Schottky Barrier |
title_full | Compact Surface Plasmon Resonance System with Au/Si Schottky Barrier |
title_fullStr | Compact Surface Plasmon Resonance System with Au/Si Schottky Barrier |
title_full_unstemmed | Compact Surface Plasmon Resonance System with Au/Si Schottky Barrier |
title_short | Compact Surface Plasmon Resonance System with Au/Si Schottky Barrier |
title_sort | compact surface plasmon resonance system with au/si schottky barrier |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5855120/ https://www.ncbi.nlm.nih.gov/pubmed/29385726 http://dx.doi.org/10.3390/s18020399 |
work_keys_str_mv | AT tsukagoshitakuya compactsurfaceplasmonresonancesystemwithausischottkybarrier AT kurodayuta compactsurfaceplasmonresonancesystemwithausischottkybarrier AT nodakentaro compactsurfaceplasmonresonancesystemwithausischottkybarrier AT binhkhiemnguyen compactsurfaceplasmonresonancesystemwithausischottkybarrier AT kantetsuo compactsurfaceplasmonresonancesystemwithausischottkybarrier AT shimoyamaisao compactsurfaceplasmonresonancesystemwithausischottkybarrier |