Quadrature Errors and DC Offsets Calibration of Analog Complex Cross-Correlator for Interferometric Passive Millimeter-Wave Imaging Applications

The design and calibration of the cross-correlator are crucial issues for interferometric imaging systems. In this paper, an analog complex cross-correlator with output DC offsets and amplitudes calibration capability is proposed for interferometric passive millimeter-wave security sensing applicati...

Descripción completa

Detalles Bibliográficos
Autores principales: Wang, Chao, Xin, Xin, Liang, Bingyuan, Li, Zhiping, Miao, Jungang
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5855241/
https://www.ncbi.nlm.nih.gov/pubmed/29495300
http://dx.doi.org/10.3390/s18020677
_version_ 1783307059881574400
author Wang, Chao
Xin, Xin
Liang, Bingyuan
Li, Zhiping
Miao, Jungang
author_facet Wang, Chao
Xin, Xin
Liang, Bingyuan
Li, Zhiping
Miao, Jungang
author_sort Wang, Chao
collection PubMed
description The design and calibration of the cross-correlator are crucial issues for interferometric imaging systems. In this paper, an analog complex cross-correlator with output DC offsets and amplitudes calibration capability is proposed for interferometric passive millimeter-wave security sensing applications. By employing digital potentiometers in the low frequency amplification circuits of the correlator, the outputs characteristics of the correlator could be digitally controlled. A measurement system and a corresponding calibration scheme were developed in order to eliminate the output DC offsets and the quadrature amplitude error between the in-phase and the quadrature correlating subunits of the complex correlator. By using vector modulators to provide phase controllable correlated noise signals, the measurement system was capable of obtaining the output correlation circle of the correlator. When injected with −18 dBm correlated noise signals, the calibrated quadrature amplitude error was 0.041 dB and the calibrated DC offsets were under 26 mV, which was only 7.1% of the uncalibrated value. Furthermore, we also described a quadrature errors calibration algorithm in order to estimate the quadrature phase error and in order to improve the output phase accuracy of the correlator. After applying this calibration, we were able to reduce the output phase error of the correlator to 0.3°.
format Online
Article
Text
id pubmed-5855241
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-58552412018-03-20 Quadrature Errors and DC Offsets Calibration of Analog Complex Cross-Correlator for Interferometric Passive Millimeter-Wave Imaging Applications Wang, Chao Xin, Xin Liang, Bingyuan Li, Zhiping Miao, Jungang Sensors (Basel) Article The design and calibration of the cross-correlator are crucial issues for interferometric imaging systems. In this paper, an analog complex cross-correlator with output DC offsets and amplitudes calibration capability is proposed for interferometric passive millimeter-wave security sensing applications. By employing digital potentiometers in the low frequency amplification circuits of the correlator, the outputs characteristics of the correlator could be digitally controlled. A measurement system and a corresponding calibration scheme were developed in order to eliminate the output DC offsets and the quadrature amplitude error between the in-phase and the quadrature correlating subunits of the complex correlator. By using vector modulators to provide phase controllable correlated noise signals, the measurement system was capable of obtaining the output correlation circle of the correlator. When injected with −18 dBm correlated noise signals, the calibrated quadrature amplitude error was 0.041 dB and the calibrated DC offsets were under 26 mV, which was only 7.1% of the uncalibrated value. Furthermore, we also described a quadrature errors calibration algorithm in order to estimate the quadrature phase error and in order to improve the output phase accuracy of the correlator. After applying this calibration, we were able to reduce the output phase error of the correlator to 0.3°. MDPI 2018-02-24 /pmc/articles/PMC5855241/ /pubmed/29495300 http://dx.doi.org/10.3390/s18020677 Text en © 2018 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Wang, Chao
Xin, Xin
Liang, Bingyuan
Li, Zhiping
Miao, Jungang
Quadrature Errors and DC Offsets Calibration of Analog Complex Cross-Correlator for Interferometric Passive Millimeter-Wave Imaging Applications
title Quadrature Errors and DC Offsets Calibration of Analog Complex Cross-Correlator for Interferometric Passive Millimeter-Wave Imaging Applications
title_full Quadrature Errors and DC Offsets Calibration of Analog Complex Cross-Correlator for Interferometric Passive Millimeter-Wave Imaging Applications
title_fullStr Quadrature Errors and DC Offsets Calibration of Analog Complex Cross-Correlator for Interferometric Passive Millimeter-Wave Imaging Applications
title_full_unstemmed Quadrature Errors and DC Offsets Calibration of Analog Complex Cross-Correlator for Interferometric Passive Millimeter-Wave Imaging Applications
title_short Quadrature Errors and DC Offsets Calibration of Analog Complex Cross-Correlator for Interferometric Passive Millimeter-Wave Imaging Applications
title_sort quadrature errors and dc offsets calibration of analog complex cross-correlator for interferometric passive millimeter-wave imaging applications
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5855241/
https://www.ncbi.nlm.nih.gov/pubmed/29495300
http://dx.doi.org/10.3390/s18020677
work_keys_str_mv AT wangchao quadratureerrorsanddcoffsetscalibrationofanalogcomplexcrosscorrelatorforinterferometricpassivemillimeterwaveimagingapplications
AT xinxin quadratureerrorsanddcoffsetscalibrationofanalogcomplexcrosscorrelatorforinterferometricpassivemillimeterwaveimagingapplications
AT liangbingyuan quadratureerrorsanddcoffsetscalibrationofanalogcomplexcrosscorrelatorforinterferometricpassivemillimeterwaveimagingapplications
AT lizhiping quadratureerrorsanddcoffsetscalibrationofanalogcomplexcrosscorrelatorforinterferometricpassivemillimeterwaveimagingapplications
AT miaojungang quadratureerrorsanddcoffsetscalibrationofanalogcomplexcrosscorrelatorforinterferometricpassivemillimeterwaveimagingapplications