Cargando…
Quadrature Errors and DC Offsets Calibration of Analog Complex Cross-Correlator for Interferometric Passive Millimeter-Wave Imaging Applications
The design and calibration of the cross-correlator are crucial issues for interferometric imaging systems. In this paper, an analog complex cross-correlator with output DC offsets and amplitudes calibration capability is proposed for interferometric passive millimeter-wave security sensing applicati...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5855241/ https://www.ncbi.nlm.nih.gov/pubmed/29495300 http://dx.doi.org/10.3390/s18020677 |
_version_ | 1783307059881574400 |
---|---|
author | Wang, Chao Xin, Xin Liang, Bingyuan Li, Zhiping Miao, Jungang |
author_facet | Wang, Chao Xin, Xin Liang, Bingyuan Li, Zhiping Miao, Jungang |
author_sort | Wang, Chao |
collection | PubMed |
description | The design and calibration of the cross-correlator are crucial issues for interferometric imaging systems. In this paper, an analog complex cross-correlator with output DC offsets and amplitudes calibration capability is proposed for interferometric passive millimeter-wave security sensing applications. By employing digital potentiometers in the low frequency amplification circuits of the correlator, the outputs characteristics of the correlator could be digitally controlled. A measurement system and a corresponding calibration scheme were developed in order to eliminate the output DC offsets and the quadrature amplitude error between the in-phase and the quadrature correlating subunits of the complex correlator. By using vector modulators to provide phase controllable correlated noise signals, the measurement system was capable of obtaining the output correlation circle of the correlator. When injected with −18 dBm correlated noise signals, the calibrated quadrature amplitude error was 0.041 dB and the calibrated DC offsets were under 26 mV, which was only 7.1% of the uncalibrated value. Furthermore, we also described a quadrature errors calibration algorithm in order to estimate the quadrature phase error and in order to improve the output phase accuracy of the correlator. After applying this calibration, we were able to reduce the output phase error of the correlator to 0.3°. |
format | Online Article Text |
id | pubmed-5855241 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-58552412018-03-20 Quadrature Errors and DC Offsets Calibration of Analog Complex Cross-Correlator for Interferometric Passive Millimeter-Wave Imaging Applications Wang, Chao Xin, Xin Liang, Bingyuan Li, Zhiping Miao, Jungang Sensors (Basel) Article The design and calibration of the cross-correlator are crucial issues for interferometric imaging systems. In this paper, an analog complex cross-correlator with output DC offsets and amplitudes calibration capability is proposed for interferometric passive millimeter-wave security sensing applications. By employing digital potentiometers in the low frequency amplification circuits of the correlator, the outputs characteristics of the correlator could be digitally controlled. A measurement system and a corresponding calibration scheme were developed in order to eliminate the output DC offsets and the quadrature amplitude error between the in-phase and the quadrature correlating subunits of the complex correlator. By using vector modulators to provide phase controllable correlated noise signals, the measurement system was capable of obtaining the output correlation circle of the correlator. When injected with −18 dBm correlated noise signals, the calibrated quadrature amplitude error was 0.041 dB and the calibrated DC offsets were under 26 mV, which was only 7.1% of the uncalibrated value. Furthermore, we also described a quadrature errors calibration algorithm in order to estimate the quadrature phase error and in order to improve the output phase accuracy of the correlator. After applying this calibration, we were able to reduce the output phase error of the correlator to 0.3°. MDPI 2018-02-24 /pmc/articles/PMC5855241/ /pubmed/29495300 http://dx.doi.org/10.3390/s18020677 Text en © 2018 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Wang, Chao Xin, Xin Liang, Bingyuan Li, Zhiping Miao, Jungang Quadrature Errors and DC Offsets Calibration of Analog Complex Cross-Correlator for Interferometric Passive Millimeter-Wave Imaging Applications |
title | Quadrature Errors and DC Offsets Calibration of Analog Complex Cross-Correlator for Interferometric Passive Millimeter-Wave Imaging Applications |
title_full | Quadrature Errors and DC Offsets Calibration of Analog Complex Cross-Correlator for Interferometric Passive Millimeter-Wave Imaging Applications |
title_fullStr | Quadrature Errors and DC Offsets Calibration of Analog Complex Cross-Correlator for Interferometric Passive Millimeter-Wave Imaging Applications |
title_full_unstemmed | Quadrature Errors and DC Offsets Calibration of Analog Complex Cross-Correlator for Interferometric Passive Millimeter-Wave Imaging Applications |
title_short | Quadrature Errors and DC Offsets Calibration of Analog Complex Cross-Correlator for Interferometric Passive Millimeter-Wave Imaging Applications |
title_sort | quadrature errors and dc offsets calibration of analog complex cross-correlator for interferometric passive millimeter-wave imaging applications |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5855241/ https://www.ncbi.nlm.nih.gov/pubmed/29495300 http://dx.doi.org/10.3390/s18020677 |
work_keys_str_mv | AT wangchao quadratureerrorsanddcoffsetscalibrationofanalogcomplexcrosscorrelatorforinterferometricpassivemillimeterwaveimagingapplications AT xinxin quadratureerrorsanddcoffsetscalibrationofanalogcomplexcrosscorrelatorforinterferometricpassivemillimeterwaveimagingapplications AT liangbingyuan quadratureerrorsanddcoffsetscalibrationofanalogcomplexcrosscorrelatorforinterferometricpassivemillimeterwaveimagingapplications AT lizhiping quadratureerrorsanddcoffsetscalibrationofanalogcomplexcrosscorrelatorforinterferometricpassivemillimeterwaveimagingapplications AT miaojungang quadratureerrorsanddcoffsetscalibrationofanalogcomplexcrosscorrelatorforinterferometricpassivemillimeterwaveimagingapplications |