Cargando…

Measurement of a 3D Ultrasonic Wavefield Using Pulsed Laser Holographic Microscopy for Ultrasonic Nondestructive Evaluation

In ultrasonic array imaging, 3D ultrasonic wavefields are normally recorded by an ultrasonic piezo array transducer. Its performance is limited by the configuration and size of the array transducer. In this paper, a method based on digital holographic interferometry is proposed to record the 3D ultr...

Descripción completa

Detalles Bibliográficos
Autores principales: Wang, Xing, Zhang, Guang-Ming, Ma, Hongwei, Zhang, Yishu, Wang, Doudou
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5855407/
https://www.ncbi.nlm.nih.gov/pubmed/29438336
http://dx.doi.org/10.3390/s18020573
_version_ 1783307096297570304
author Wang, Xing
Zhang, Guang-Ming
Ma, Hongwei
Zhang, Yishu
Wang, Doudou
author_facet Wang, Xing
Zhang, Guang-Ming
Ma, Hongwei
Zhang, Yishu
Wang, Doudou
author_sort Wang, Xing
collection PubMed
description In ultrasonic array imaging, 3D ultrasonic wavefields are normally recorded by an ultrasonic piezo array transducer. Its performance is limited by the configuration and size of the array transducer. In this paper, a method based on digital holographic interferometry is proposed to record the 3D ultrasonic wavefields instead of the array transducer, and the measurement system consisting of a pulsed laser, ultrasonic excitation, and synchronization and control circuit is designed. A consecutive sequence of holograms of ultrasonic wavefields are recorded by the system. The interferograms are calculated from the recorded holograms at different time sequence. The amplitudes and phases of the transient ultrasonic wavefields are recovered from the interferograms by phase unwrapping. The consecutive sequence of transient ultrasonic wavefields are stacked together to generate 3D ultrasonic wavefields. Simulation and experiments are carried out to verify the proposed technique, and preliminary results are presented.
format Online
Article
Text
id pubmed-5855407
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-58554072018-03-20 Measurement of a 3D Ultrasonic Wavefield Using Pulsed Laser Holographic Microscopy for Ultrasonic Nondestructive Evaluation Wang, Xing Zhang, Guang-Ming Ma, Hongwei Zhang, Yishu Wang, Doudou Sensors (Basel) Article In ultrasonic array imaging, 3D ultrasonic wavefields are normally recorded by an ultrasonic piezo array transducer. Its performance is limited by the configuration and size of the array transducer. In this paper, a method based on digital holographic interferometry is proposed to record the 3D ultrasonic wavefields instead of the array transducer, and the measurement system consisting of a pulsed laser, ultrasonic excitation, and synchronization and control circuit is designed. A consecutive sequence of holograms of ultrasonic wavefields are recorded by the system. The interferograms are calculated from the recorded holograms at different time sequence. The amplitudes and phases of the transient ultrasonic wavefields are recovered from the interferograms by phase unwrapping. The consecutive sequence of transient ultrasonic wavefields are stacked together to generate 3D ultrasonic wavefields. Simulation and experiments are carried out to verify the proposed technique, and preliminary results are presented. MDPI 2018-02-13 /pmc/articles/PMC5855407/ /pubmed/29438336 http://dx.doi.org/10.3390/s18020573 Text en © 2018 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Wang, Xing
Zhang, Guang-Ming
Ma, Hongwei
Zhang, Yishu
Wang, Doudou
Measurement of a 3D Ultrasonic Wavefield Using Pulsed Laser Holographic Microscopy for Ultrasonic Nondestructive Evaluation
title Measurement of a 3D Ultrasonic Wavefield Using Pulsed Laser Holographic Microscopy for Ultrasonic Nondestructive Evaluation
title_full Measurement of a 3D Ultrasonic Wavefield Using Pulsed Laser Holographic Microscopy for Ultrasonic Nondestructive Evaluation
title_fullStr Measurement of a 3D Ultrasonic Wavefield Using Pulsed Laser Holographic Microscopy for Ultrasonic Nondestructive Evaluation
title_full_unstemmed Measurement of a 3D Ultrasonic Wavefield Using Pulsed Laser Holographic Microscopy for Ultrasonic Nondestructive Evaluation
title_short Measurement of a 3D Ultrasonic Wavefield Using Pulsed Laser Holographic Microscopy for Ultrasonic Nondestructive Evaluation
title_sort measurement of a 3d ultrasonic wavefield using pulsed laser holographic microscopy for ultrasonic nondestructive evaluation
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5855407/
https://www.ncbi.nlm.nih.gov/pubmed/29438336
http://dx.doi.org/10.3390/s18020573
work_keys_str_mv AT wangxing measurementofa3dultrasonicwavefieldusingpulsedlaserholographicmicroscopyforultrasonicnondestructiveevaluation
AT zhangguangming measurementofa3dultrasonicwavefieldusingpulsedlaserholographicmicroscopyforultrasonicnondestructiveevaluation
AT mahongwei measurementofa3dultrasonicwavefieldusingpulsedlaserholographicmicroscopyforultrasonicnondestructiveevaluation
AT zhangyishu measurementofa3dultrasonicwavefieldusingpulsedlaserholographicmicroscopyforultrasonicnondestructiveevaluation
AT wangdoudou measurementofa3dultrasonicwavefieldusingpulsedlaserholographicmicroscopyforultrasonicnondestructiveevaluation