Cargando…
Measurement of a 3D Ultrasonic Wavefield Using Pulsed Laser Holographic Microscopy for Ultrasonic Nondestructive Evaluation
In ultrasonic array imaging, 3D ultrasonic wavefields are normally recorded by an ultrasonic piezo array transducer. Its performance is limited by the configuration and size of the array transducer. In this paper, a method based on digital holographic interferometry is proposed to record the 3D ultr...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5855407/ https://www.ncbi.nlm.nih.gov/pubmed/29438336 http://dx.doi.org/10.3390/s18020573 |
_version_ | 1783307096297570304 |
---|---|
author | Wang, Xing Zhang, Guang-Ming Ma, Hongwei Zhang, Yishu Wang, Doudou |
author_facet | Wang, Xing Zhang, Guang-Ming Ma, Hongwei Zhang, Yishu Wang, Doudou |
author_sort | Wang, Xing |
collection | PubMed |
description | In ultrasonic array imaging, 3D ultrasonic wavefields are normally recorded by an ultrasonic piezo array transducer. Its performance is limited by the configuration and size of the array transducer. In this paper, a method based on digital holographic interferometry is proposed to record the 3D ultrasonic wavefields instead of the array transducer, and the measurement system consisting of a pulsed laser, ultrasonic excitation, and synchronization and control circuit is designed. A consecutive sequence of holograms of ultrasonic wavefields are recorded by the system. The interferograms are calculated from the recorded holograms at different time sequence. The amplitudes and phases of the transient ultrasonic wavefields are recovered from the interferograms by phase unwrapping. The consecutive sequence of transient ultrasonic wavefields are stacked together to generate 3D ultrasonic wavefields. Simulation and experiments are carried out to verify the proposed technique, and preliminary results are presented. |
format | Online Article Text |
id | pubmed-5855407 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-58554072018-03-20 Measurement of a 3D Ultrasonic Wavefield Using Pulsed Laser Holographic Microscopy for Ultrasonic Nondestructive Evaluation Wang, Xing Zhang, Guang-Ming Ma, Hongwei Zhang, Yishu Wang, Doudou Sensors (Basel) Article In ultrasonic array imaging, 3D ultrasonic wavefields are normally recorded by an ultrasonic piezo array transducer. Its performance is limited by the configuration and size of the array transducer. In this paper, a method based on digital holographic interferometry is proposed to record the 3D ultrasonic wavefields instead of the array transducer, and the measurement system consisting of a pulsed laser, ultrasonic excitation, and synchronization and control circuit is designed. A consecutive sequence of holograms of ultrasonic wavefields are recorded by the system. The interferograms are calculated from the recorded holograms at different time sequence. The amplitudes and phases of the transient ultrasonic wavefields are recovered from the interferograms by phase unwrapping. The consecutive sequence of transient ultrasonic wavefields are stacked together to generate 3D ultrasonic wavefields. Simulation and experiments are carried out to verify the proposed technique, and preliminary results are presented. MDPI 2018-02-13 /pmc/articles/PMC5855407/ /pubmed/29438336 http://dx.doi.org/10.3390/s18020573 Text en © 2018 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Wang, Xing Zhang, Guang-Ming Ma, Hongwei Zhang, Yishu Wang, Doudou Measurement of a 3D Ultrasonic Wavefield Using Pulsed Laser Holographic Microscopy for Ultrasonic Nondestructive Evaluation |
title | Measurement of a 3D Ultrasonic Wavefield Using Pulsed Laser Holographic Microscopy for Ultrasonic Nondestructive Evaluation |
title_full | Measurement of a 3D Ultrasonic Wavefield Using Pulsed Laser Holographic Microscopy for Ultrasonic Nondestructive Evaluation |
title_fullStr | Measurement of a 3D Ultrasonic Wavefield Using Pulsed Laser Holographic Microscopy for Ultrasonic Nondestructive Evaluation |
title_full_unstemmed | Measurement of a 3D Ultrasonic Wavefield Using Pulsed Laser Holographic Microscopy for Ultrasonic Nondestructive Evaluation |
title_short | Measurement of a 3D Ultrasonic Wavefield Using Pulsed Laser Holographic Microscopy for Ultrasonic Nondestructive Evaluation |
title_sort | measurement of a 3d ultrasonic wavefield using pulsed laser holographic microscopy for ultrasonic nondestructive evaluation |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5855407/ https://www.ncbi.nlm.nih.gov/pubmed/29438336 http://dx.doi.org/10.3390/s18020573 |
work_keys_str_mv | AT wangxing measurementofa3dultrasonicwavefieldusingpulsedlaserholographicmicroscopyforultrasonicnondestructiveevaluation AT zhangguangming measurementofa3dultrasonicwavefieldusingpulsedlaserholographicmicroscopyforultrasonicnondestructiveevaluation AT mahongwei measurementofa3dultrasonicwavefieldusingpulsedlaserholographicmicroscopyforultrasonicnondestructiveevaluation AT zhangyishu measurementofa3dultrasonicwavefieldusingpulsedlaserholographicmicroscopyforultrasonicnondestructiveevaluation AT wangdoudou measurementofa3dultrasonicwavefieldusingpulsedlaserholographicmicroscopyforultrasonicnondestructiveevaluation |