Cargando…

Detection of Thrombin Based on Fluorescence Energy Transfer between Semiconducting Polymer Dots and BHQ-Labelled Aptamers

Carboxyl-functionalized semiconducting polymer dots (Pdots) were synthesized as an energy donor by the nanoprecipitation method. A black hole quenching dye (BHQ-labelled thrombin aptamers) was used as the energy acceptor, and fluorescence resonance energy transfer between the aptamers and Pdots was...

Descripción completa

Detalles Bibliográficos
Autores principales: Liu, Yizhang, Jiang, Xuekai, Cao, Wenfeng, Sun, Junyong, Gao, Feng
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5855441/
https://www.ncbi.nlm.nih.gov/pubmed/29443917
http://dx.doi.org/10.3390/s18020589
_version_ 1783307097698467840
author Liu, Yizhang
Jiang, Xuekai
Cao, Wenfeng
Sun, Junyong
Gao, Feng
author_facet Liu, Yizhang
Jiang, Xuekai
Cao, Wenfeng
Sun, Junyong
Gao, Feng
author_sort Liu, Yizhang
collection PubMed
description Carboxyl-functionalized semiconducting polymer dots (Pdots) were synthesized as an energy donor by the nanoprecipitation method. A black hole quenching dye (BHQ-labelled thrombin aptamers) was used as the energy acceptor, and fluorescence resonance energy transfer between the aptamers and Pdots was used for fluorescence quenching of the Pdots. The addition of thrombin restored the fluorescence intensity. Under the optimized experimental conditions, the fluorescence of the system was restored to the maximum when the concentration of thrombin reached 130 nM, with a linear range of 0–50 nM (R(2) = 0.990) and a detection limit of 0.33 nM. This sensor was less disturbed by impurities, showing good specificity and signal response to thrombin, with good application in actual samples. The detection of human serum showed good linearity in the range of 0–30 nM (R(2) = 0.997), with a detection limit of 0.56 nM and a recovery rate of 96.2–104.1%, indicating that this fluorescence sensor can be used for the detection of thrombin content in human serum.
format Online
Article
Text
id pubmed-5855441
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-58554412018-03-20 Detection of Thrombin Based on Fluorescence Energy Transfer between Semiconducting Polymer Dots and BHQ-Labelled Aptamers Liu, Yizhang Jiang, Xuekai Cao, Wenfeng Sun, Junyong Gao, Feng Sensors (Basel) Article Carboxyl-functionalized semiconducting polymer dots (Pdots) were synthesized as an energy donor by the nanoprecipitation method. A black hole quenching dye (BHQ-labelled thrombin aptamers) was used as the energy acceptor, and fluorescence resonance energy transfer between the aptamers and Pdots was used for fluorescence quenching of the Pdots. The addition of thrombin restored the fluorescence intensity. Under the optimized experimental conditions, the fluorescence of the system was restored to the maximum when the concentration of thrombin reached 130 nM, with a linear range of 0–50 nM (R(2) = 0.990) and a detection limit of 0.33 nM. This sensor was less disturbed by impurities, showing good specificity and signal response to thrombin, with good application in actual samples. The detection of human serum showed good linearity in the range of 0–30 nM (R(2) = 0.997), with a detection limit of 0.56 nM and a recovery rate of 96.2–104.1%, indicating that this fluorescence sensor can be used for the detection of thrombin content in human serum. MDPI 2018-02-14 /pmc/articles/PMC5855441/ /pubmed/29443917 http://dx.doi.org/10.3390/s18020589 Text en © 2018 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Liu, Yizhang
Jiang, Xuekai
Cao, Wenfeng
Sun, Junyong
Gao, Feng
Detection of Thrombin Based on Fluorescence Energy Transfer between Semiconducting Polymer Dots and BHQ-Labelled Aptamers
title Detection of Thrombin Based on Fluorescence Energy Transfer between Semiconducting Polymer Dots and BHQ-Labelled Aptamers
title_full Detection of Thrombin Based on Fluorescence Energy Transfer between Semiconducting Polymer Dots and BHQ-Labelled Aptamers
title_fullStr Detection of Thrombin Based on Fluorescence Energy Transfer between Semiconducting Polymer Dots and BHQ-Labelled Aptamers
title_full_unstemmed Detection of Thrombin Based on Fluorescence Energy Transfer between Semiconducting Polymer Dots and BHQ-Labelled Aptamers
title_short Detection of Thrombin Based on Fluorescence Energy Transfer between Semiconducting Polymer Dots and BHQ-Labelled Aptamers
title_sort detection of thrombin based on fluorescence energy transfer between semiconducting polymer dots and bhq-labelled aptamers
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5855441/
https://www.ncbi.nlm.nih.gov/pubmed/29443917
http://dx.doi.org/10.3390/s18020589
work_keys_str_mv AT liuyizhang detectionofthrombinbasedonfluorescenceenergytransferbetweensemiconductingpolymerdotsandbhqlabelledaptamers
AT jiangxuekai detectionofthrombinbasedonfluorescenceenergytransferbetweensemiconductingpolymerdotsandbhqlabelledaptamers
AT caowenfeng detectionofthrombinbasedonfluorescenceenergytransferbetweensemiconductingpolymerdotsandbhqlabelledaptamers
AT sunjunyong detectionofthrombinbasedonfluorescenceenergytransferbetweensemiconductingpolymerdotsandbhqlabelledaptamers
AT gaofeng detectionofthrombinbasedonfluorescenceenergytransferbetweensemiconductingpolymerdotsandbhqlabelledaptamers