Cargando…

A Robust Static Headspace GC-FID Method to Detect and Quantify Formaldehyde Impurity in Pharmaceutical Excipients

Formaldehyde is a highly reactive impurity that can be found in many pharmaceutical excipients. Trace levels of this impurity may affect drug product stability, safety, efficacy, and performance. A static headspace gas chromatographic method was developed and validated to determine formaldehyde in p...

Descripción completa

Detalles Bibliográficos
Autores principales: Daoud Agha Dit Daoudy, Bashir, Al-Khayat, Mohammad Ammar, Karabet, Francois, Al-Mardini, Mohammad Amer
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5857322/
https://www.ncbi.nlm.nih.gov/pubmed/29686930
http://dx.doi.org/10.1155/2018/4526396
_version_ 1783307449713819648
author Daoud Agha Dit Daoudy, Bashir
Al-Khayat, Mohammad Ammar
Karabet, Francois
Al-Mardini, Mohammad Amer
author_facet Daoud Agha Dit Daoudy, Bashir
Al-Khayat, Mohammad Ammar
Karabet, Francois
Al-Mardini, Mohammad Amer
author_sort Daoud Agha Dit Daoudy, Bashir
collection PubMed
description Formaldehyde is a highly reactive impurity that can be found in many pharmaceutical excipients. Trace levels of this impurity may affect drug product stability, safety, efficacy, and performance. A static headspace gas chromatographic method was developed and validated to determine formaldehyde in pharmaceutical excipients after an effective derivatization procedure using acidified ethanol. Diethoxymethane, the derivative of formaldehyde, was then directly analyzed by GC-FID. Despite the simplicity of the developed method, however, it is characterized by its specificity, accuracy, and precision. The limits of detection and quantification of formaldehyde in the samples were of 2.44 and 8.12 µg/g, respectively. This method is characterized by using simple and economic GC-FID technique instead of MS detection, and it is successfully used to analyze formaldehyde in commonly used pharmaceutical excipients.
format Online
Article
Text
id pubmed-5857322
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-58573222018-04-23 A Robust Static Headspace GC-FID Method to Detect and Quantify Formaldehyde Impurity in Pharmaceutical Excipients Daoud Agha Dit Daoudy, Bashir Al-Khayat, Mohammad Ammar Karabet, Francois Al-Mardini, Mohammad Amer J Anal Methods Chem Research Article Formaldehyde is a highly reactive impurity that can be found in many pharmaceutical excipients. Trace levels of this impurity may affect drug product stability, safety, efficacy, and performance. A static headspace gas chromatographic method was developed and validated to determine formaldehyde in pharmaceutical excipients after an effective derivatization procedure using acidified ethanol. Diethoxymethane, the derivative of formaldehyde, was then directly analyzed by GC-FID. Despite the simplicity of the developed method, however, it is characterized by its specificity, accuracy, and precision. The limits of detection and quantification of formaldehyde in the samples were of 2.44 and 8.12 µg/g, respectively. This method is characterized by using simple and economic GC-FID technique instead of MS detection, and it is successfully used to analyze formaldehyde in commonly used pharmaceutical excipients. Hindawi 2018-03-04 /pmc/articles/PMC5857322/ /pubmed/29686930 http://dx.doi.org/10.1155/2018/4526396 Text en Copyright © 2018 Bashir Daoud Agha Dit Daoudy et al. http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Daoud Agha Dit Daoudy, Bashir
Al-Khayat, Mohammad Ammar
Karabet, Francois
Al-Mardini, Mohammad Amer
A Robust Static Headspace GC-FID Method to Detect and Quantify Formaldehyde Impurity in Pharmaceutical Excipients
title A Robust Static Headspace GC-FID Method to Detect and Quantify Formaldehyde Impurity in Pharmaceutical Excipients
title_full A Robust Static Headspace GC-FID Method to Detect and Quantify Formaldehyde Impurity in Pharmaceutical Excipients
title_fullStr A Robust Static Headspace GC-FID Method to Detect and Quantify Formaldehyde Impurity in Pharmaceutical Excipients
title_full_unstemmed A Robust Static Headspace GC-FID Method to Detect and Quantify Formaldehyde Impurity in Pharmaceutical Excipients
title_short A Robust Static Headspace GC-FID Method to Detect and Quantify Formaldehyde Impurity in Pharmaceutical Excipients
title_sort robust static headspace gc-fid method to detect and quantify formaldehyde impurity in pharmaceutical excipients
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5857322/
https://www.ncbi.nlm.nih.gov/pubmed/29686930
http://dx.doi.org/10.1155/2018/4526396
work_keys_str_mv AT daoudaghaditdaoudybashir arobuststaticheadspacegcfidmethodtodetectandquantifyformaldehydeimpurityinpharmaceuticalexcipients
AT alkhayatmohammadammar arobuststaticheadspacegcfidmethodtodetectandquantifyformaldehydeimpurityinpharmaceuticalexcipients
AT karabetfrancois arobuststaticheadspacegcfidmethodtodetectandquantifyformaldehydeimpurityinpharmaceuticalexcipients
AT almardinimohammadamer arobuststaticheadspacegcfidmethodtodetectandquantifyformaldehydeimpurityinpharmaceuticalexcipients
AT daoudaghaditdaoudybashir robuststaticheadspacegcfidmethodtodetectandquantifyformaldehydeimpurityinpharmaceuticalexcipients
AT alkhayatmohammadammar robuststaticheadspacegcfidmethodtodetectandquantifyformaldehydeimpurityinpharmaceuticalexcipients
AT karabetfrancois robuststaticheadspacegcfidmethodtodetectandquantifyformaldehydeimpurityinpharmaceuticalexcipients
AT almardinimohammadamer robuststaticheadspacegcfidmethodtodetectandquantifyformaldehydeimpurityinpharmaceuticalexcipients