Cargando…
Error Analysis: How Precise is Fused Deposition Modeling in Fabrication of Bone Models in Comparison to the Parent Bones?
BACKGROUND: Rapid prototyping (RP) is used widely in dental and faciomaxillary surgery with anecdotal uses in orthopedics. The purview of RP in orthopedics is vast. However, there is no error analysis reported in the literature on bone models generated using office-based RP. This study evaluates the...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Medknow Publications & Media Pvt Ltd
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5858215/ https://www.ncbi.nlm.nih.gov/pubmed/29576649 http://dx.doi.org/10.4103/ortho.IJOrtho_312_16 |
_version_ | 1783307610399703040 |
---|---|
author | Reddy, M V Eachempati, Krishnakiran Gurava Reddy, A V Mugalur, Aakash |
author_facet | Reddy, M V Eachempati, Krishnakiran Gurava Reddy, A V Mugalur, Aakash |
author_sort | Reddy, M V |
collection | PubMed |
description | BACKGROUND: Rapid prototyping (RP) is used widely in dental and faciomaxillary surgery with anecdotal uses in orthopedics. The purview of RP in orthopedics is vast. However, there is no error analysis reported in the literature on bone models generated using office-based RP. This study evaluates the accuracy of fused deposition modeling (FDM) using standard tessellation language (STL) files and errors generated during the fabrication of bone models. MATERIALS AND METHODS: Nine dry bones were selected and were computed tomography (CT) scanned. STL files were procured from the CT scans and three-dimensional (3D) models of the bones were printed using our in-house FDM based 3D printer using Acrylonitrile Butadiene Styrene (ABS) filament. Measurements were made on the bone and 3D models according to data collection procedures for forensic skeletal material. Statistical analysis was performed to establish interobserver co-relation for measurements on dry bones and the 3D bone models. Statistical analysis was performed using SPSS version 13.0 software to analyze the collected data. RESULTS: The inter-observer reliability was established using intra-class coefficient for both the dry bones and the 3D models. The mean of absolute difference is 0.4 that is very minimal. The 3D models are comparable to the dry bones. CONCLUSIONS: STL file dependent FDM using ABS material produces near-anatomical 3D models. The high 3D accuracy hold a promise in the clinical scenario for preoperative planning, mock surgery, and choice of implants and prostheses, especially in complicated acetabular trauma and complex hip surgeries. |
format | Online Article Text |
id | pubmed-5858215 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Medknow Publications & Media Pvt Ltd |
record_format | MEDLINE/PubMed |
spelling | pubmed-58582152018-03-23 Error Analysis: How Precise is Fused Deposition Modeling in Fabrication of Bone Models in Comparison to the Parent Bones? Reddy, M V Eachempati, Krishnakiran Gurava Reddy, A V Mugalur, Aakash Indian J Orthop Original Article - Basic Sciences BACKGROUND: Rapid prototyping (RP) is used widely in dental and faciomaxillary surgery with anecdotal uses in orthopedics. The purview of RP in orthopedics is vast. However, there is no error analysis reported in the literature on bone models generated using office-based RP. This study evaluates the accuracy of fused deposition modeling (FDM) using standard tessellation language (STL) files and errors generated during the fabrication of bone models. MATERIALS AND METHODS: Nine dry bones were selected and were computed tomography (CT) scanned. STL files were procured from the CT scans and three-dimensional (3D) models of the bones were printed using our in-house FDM based 3D printer using Acrylonitrile Butadiene Styrene (ABS) filament. Measurements were made on the bone and 3D models according to data collection procedures for forensic skeletal material. Statistical analysis was performed to establish interobserver co-relation for measurements on dry bones and the 3D bone models. Statistical analysis was performed using SPSS version 13.0 software to analyze the collected data. RESULTS: The inter-observer reliability was established using intra-class coefficient for both the dry bones and the 3D models. The mean of absolute difference is 0.4 that is very minimal. The 3D models are comparable to the dry bones. CONCLUSIONS: STL file dependent FDM using ABS material produces near-anatomical 3D models. The high 3D accuracy hold a promise in the clinical scenario for preoperative planning, mock surgery, and choice of implants and prostheses, especially in complicated acetabular trauma and complex hip surgeries. Medknow Publications & Media Pvt Ltd 2018 /pmc/articles/PMC5858215/ /pubmed/29576649 http://dx.doi.org/10.4103/ortho.IJOrtho_312_16 Text en Copyright: © 2018 Indian Journal of Orthopaedics http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 3.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as the author is credited and the new creations are licensed under the identical terms. |
spellingShingle | Original Article - Basic Sciences Reddy, M V Eachempati, Krishnakiran Gurava Reddy, A V Mugalur, Aakash Error Analysis: How Precise is Fused Deposition Modeling in Fabrication of Bone Models in Comparison to the Parent Bones? |
title | Error Analysis: How Precise is Fused Deposition Modeling in Fabrication of Bone Models in Comparison to the Parent Bones? |
title_full | Error Analysis: How Precise is Fused Deposition Modeling in Fabrication of Bone Models in Comparison to the Parent Bones? |
title_fullStr | Error Analysis: How Precise is Fused Deposition Modeling in Fabrication of Bone Models in Comparison to the Parent Bones? |
title_full_unstemmed | Error Analysis: How Precise is Fused Deposition Modeling in Fabrication of Bone Models in Comparison to the Parent Bones? |
title_short | Error Analysis: How Precise is Fused Deposition Modeling in Fabrication of Bone Models in Comparison to the Parent Bones? |
title_sort | error analysis: how precise is fused deposition modeling in fabrication of bone models in comparison to the parent bones? |
topic | Original Article - Basic Sciences |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5858215/ https://www.ncbi.nlm.nih.gov/pubmed/29576649 http://dx.doi.org/10.4103/ortho.IJOrtho_312_16 |
work_keys_str_mv | AT reddymv erroranalysishowpreciseisfuseddepositionmodelinginfabricationofbonemodelsincomparisontotheparentbones AT eachempatikrishnakiran erroranalysishowpreciseisfuseddepositionmodelinginfabricationofbonemodelsincomparisontotheparentbones AT guravareddyav erroranalysishowpreciseisfuseddepositionmodelinginfabricationofbonemodelsincomparisontotheparentbones AT mugaluraakash erroranalysishowpreciseisfuseddepositionmodelinginfabricationofbonemodelsincomparisontotheparentbones |