Cargando…

Error Analysis: How Precise is Fused Deposition Modeling in Fabrication of Bone Models in Comparison to the Parent Bones?

BACKGROUND: Rapid prototyping (RP) is used widely in dental and faciomaxillary surgery with anecdotal uses in orthopedics. The purview of RP in orthopedics is vast. However, there is no error analysis reported in the literature on bone models generated using office-based RP. This study evaluates the...

Descripción completa

Detalles Bibliográficos
Autores principales: Reddy, M V, Eachempati, Krishnakiran, Gurava Reddy, A V, Mugalur, Aakash
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5858215/
https://www.ncbi.nlm.nih.gov/pubmed/29576649
http://dx.doi.org/10.4103/ortho.IJOrtho_312_16
_version_ 1783307610399703040
author Reddy, M V
Eachempati, Krishnakiran
Gurava Reddy, A V
Mugalur, Aakash
author_facet Reddy, M V
Eachempati, Krishnakiran
Gurava Reddy, A V
Mugalur, Aakash
author_sort Reddy, M V
collection PubMed
description BACKGROUND: Rapid prototyping (RP) is used widely in dental and faciomaxillary surgery with anecdotal uses in orthopedics. The purview of RP in orthopedics is vast. However, there is no error analysis reported in the literature on bone models generated using office-based RP. This study evaluates the accuracy of fused deposition modeling (FDM) using standard tessellation language (STL) files and errors generated during the fabrication of bone models. MATERIALS AND METHODS: Nine dry bones were selected and were computed tomography (CT) scanned. STL files were procured from the CT scans and three-dimensional (3D) models of the bones were printed using our in-house FDM based 3D printer using Acrylonitrile Butadiene Styrene (ABS) filament. Measurements were made on the bone and 3D models according to data collection procedures for forensic skeletal material. Statistical analysis was performed to establish interobserver co-relation for measurements on dry bones and the 3D bone models. Statistical analysis was performed using SPSS version 13.0 software to analyze the collected data. RESULTS: The inter-observer reliability was established using intra-class coefficient for both the dry bones and the 3D models. The mean of absolute difference is 0.4 that is very minimal. The 3D models are comparable to the dry bones. CONCLUSIONS: STL file dependent FDM using ABS material produces near-anatomical 3D models. The high 3D accuracy hold a promise in the clinical scenario for preoperative planning, mock surgery, and choice of implants and prostheses, especially in complicated acetabular trauma and complex hip surgeries.
format Online
Article
Text
id pubmed-5858215
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-58582152018-03-23 Error Analysis: How Precise is Fused Deposition Modeling in Fabrication of Bone Models in Comparison to the Parent Bones? Reddy, M V Eachempati, Krishnakiran Gurava Reddy, A V Mugalur, Aakash Indian J Orthop Original Article - Basic Sciences BACKGROUND: Rapid prototyping (RP) is used widely in dental and faciomaxillary surgery with anecdotal uses in orthopedics. The purview of RP in orthopedics is vast. However, there is no error analysis reported in the literature on bone models generated using office-based RP. This study evaluates the accuracy of fused deposition modeling (FDM) using standard tessellation language (STL) files and errors generated during the fabrication of bone models. MATERIALS AND METHODS: Nine dry bones were selected and were computed tomography (CT) scanned. STL files were procured from the CT scans and three-dimensional (3D) models of the bones were printed using our in-house FDM based 3D printer using Acrylonitrile Butadiene Styrene (ABS) filament. Measurements were made on the bone and 3D models according to data collection procedures for forensic skeletal material. Statistical analysis was performed to establish interobserver co-relation for measurements on dry bones and the 3D bone models. Statistical analysis was performed using SPSS version 13.0 software to analyze the collected data. RESULTS: The inter-observer reliability was established using intra-class coefficient for both the dry bones and the 3D models. The mean of absolute difference is 0.4 that is very minimal. The 3D models are comparable to the dry bones. CONCLUSIONS: STL file dependent FDM using ABS material produces near-anatomical 3D models. The high 3D accuracy hold a promise in the clinical scenario for preoperative planning, mock surgery, and choice of implants and prostheses, especially in complicated acetabular trauma and complex hip surgeries. Medknow Publications & Media Pvt Ltd 2018 /pmc/articles/PMC5858215/ /pubmed/29576649 http://dx.doi.org/10.4103/ortho.IJOrtho_312_16 Text en Copyright: © 2018 Indian Journal of Orthopaedics http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 3.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as the author is credited and the new creations are licensed under the identical terms.
spellingShingle Original Article - Basic Sciences
Reddy, M V
Eachempati, Krishnakiran
Gurava Reddy, A V
Mugalur, Aakash
Error Analysis: How Precise is Fused Deposition Modeling in Fabrication of Bone Models in Comparison to the Parent Bones?
title Error Analysis: How Precise is Fused Deposition Modeling in Fabrication of Bone Models in Comparison to the Parent Bones?
title_full Error Analysis: How Precise is Fused Deposition Modeling in Fabrication of Bone Models in Comparison to the Parent Bones?
title_fullStr Error Analysis: How Precise is Fused Deposition Modeling in Fabrication of Bone Models in Comparison to the Parent Bones?
title_full_unstemmed Error Analysis: How Precise is Fused Deposition Modeling in Fabrication of Bone Models in Comparison to the Parent Bones?
title_short Error Analysis: How Precise is Fused Deposition Modeling in Fabrication of Bone Models in Comparison to the Parent Bones?
title_sort error analysis: how precise is fused deposition modeling in fabrication of bone models in comparison to the parent bones?
topic Original Article - Basic Sciences
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5858215/
https://www.ncbi.nlm.nih.gov/pubmed/29576649
http://dx.doi.org/10.4103/ortho.IJOrtho_312_16
work_keys_str_mv AT reddymv erroranalysishowpreciseisfuseddepositionmodelinginfabricationofbonemodelsincomparisontotheparentbones
AT eachempatikrishnakiran erroranalysishowpreciseisfuseddepositionmodelinginfabricationofbonemodelsincomparisontotheparentbones
AT guravareddyav erroranalysishowpreciseisfuseddepositionmodelinginfabricationofbonemodelsincomparisontotheparentbones
AT mugaluraakash erroranalysishowpreciseisfuseddepositionmodelinginfabricationofbonemodelsincomparisontotheparentbones