Comparison of OKULIX ray-tracing software with SRK-T and Hoffer-Q formula in intraocular lens power calculation

PURPOSE: To compare the performance of OKULIX ray-tracing software with SRK-T and Hoffer Q formula in intraocular lens (IOL) power calculation in patients presenting with cataract. METHODS: In this prospective study, 104 eyes of 104 patients with cataract who underwent phacoemulsification and IOL im...

Descripción completa

Detalles Bibliográficos
Autores principales: Ghoreyshi, Mohammad, Khalilian, Ahmadreza, Peyman, Mohammadreza, Mohammadinia, Mohaddeseh, Peyman, Alireza
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5859630/
https://www.ncbi.nlm.nih.gov/pubmed/29564411
http://dx.doi.org/10.1016/j.joco.2017.06.008
_version_ 1783307859949256704
author Ghoreyshi, Mohammad
Khalilian, Ahmadreza
Peyman, Mohammadreza
Mohammadinia, Mohaddeseh
Peyman, Alireza
author_facet Ghoreyshi, Mohammad
Khalilian, Ahmadreza
Peyman, Mohammadreza
Mohammadinia, Mohaddeseh
Peyman, Alireza
author_sort Ghoreyshi, Mohammad
collection PubMed
description PURPOSE: To compare the performance of OKULIX ray-tracing software with SRK-T and Hoffer Q formula in intraocular lens (IOL) power calculation in patients presenting with cataract. METHODS: In this prospective study, 104 eyes of 104 patients with cataract who underwent phacoemulsification and IOL implantation were recruited. Three IOL brands were used and for all eyes, IOL power calculation was performed using SRK-T, Hoffer Q formula and also OKULIX ray-tracing software. For all patients, axial length and keratometry data was obtained with IOLMaster 500 device and IOL power was determined using Hoffer Q and SRK-T formula. The IOL powers were also calculated using the OKULIX ray-tracing software combined with CASIA AS-OCT and IOLMaster 500 device. Optically measured axial length of eyes were inserted to OKULIX software from IOLMaster 500 device, and anterior and posterior tomographic and corneal pachymetry data was imported from CASIA AS-OCT into the OKULIX. The performance of each calculation methods was measured by subtracting the predicted postoperative refraction from the postoperative manifest refraction spherical equivalent (MRSE). For each of the 3 methods, the mean absolute prediction error was determined, too. RESULTS: The mean value absolute prediction error by OKULIX, SRK-T and Hoffer Q formulas, respectively, were 0.42 (±0.03), 0.36 (±0.02) and 0.37 (±0.02). The mean absolute prediction error by OKULIX had no significant difference between three IOL groups (P = 0.96), and it was confirmed that there was no meaningful statistically difference in mean absolute prediction error between the OKULIX, SRK-T and Hoffer Q formula. (P = 0.25). Also in each group of implanted IOLs, all three formulas worked with the same accuracy. The prediction error using OKULIX were within ±0.50 diopter in 63.5% of eyes and within ±1.00 diopter in 94.2% of eyes. CONCLUSION: OKULIX ray-tracing IOL power measurements provides reliable and satisfactory postoperative results, which are comparable to other 3rd generation formulas of SRK-T and Hoffer Q.
format Online
Article
Text
id pubmed-5859630
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-58596302018-03-21 Comparison of OKULIX ray-tracing software with SRK-T and Hoffer-Q formula in intraocular lens power calculation Ghoreyshi, Mohammad Khalilian, Ahmadreza Peyman, Mohammadreza Mohammadinia, Mohaddeseh Peyman, Alireza J Curr Ophthalmol Article PURPOSE: To compare the performance of OKULIX ray-tracing software with SRK-T and Hoffer Q formula in intraocular lens (IOL) power calculation in patients presenting with cataract. METHODS: In this prospective study, 104 eyes of 104 patients with cataract who underwent phacoemulsification and IOL implantation were recruited. Three IOL brands were used and for all eyes, IOL power calculation was performed using SRK-T, Hoffer Q formula and also OKULIX ray-tracing software. For all patients, axial length and keratometry data was obtained with IOLMaster 500 device and IOL power was determined using Hoffer Q and SRK-T formula. The IOL powers were also calculated using the OKULIX ray-tracing software combined with CASIA AS-OCT and IOLMaster 500 device. Optically measured axial length of eyes were inserted to OKULIX software from IOLMaster 500 device, and anterior and posterior tomographic and corneal pachymetry data was imported from CASIA AS-OCT into the OKULIX. The performance of each calculation methods was measured by subtracting the predicted postoperative refraction from the postoperative manifest refraction spherical equivalent (MRSE). For each of the 3 methods, the mean absolute prediction error was determined, too. RESULTS: The mean value absolute prediction error by OKULIX, SRK-T and Hoffer Q formulas, respectively, were 0.42 (±0.03), 0.36 (±0.02) and 0.37 (±0.02). The mean absolute prediction error by OKULIX had no significant difference between three IOL groups (P = 0.96), and it was confirmed that there was no meaningful statistically difference in mean absolute prediction error between the OKULIX, SRK-T and Hoffer Q formula. (P = 0.25). Also in each group of implanted IOLs, all three formulas worked with the same accuracy. The prediction error using OKULIX were within ±0.50 diopter in 63.5% of eyes and within ±1.00 diopter in 94.2% of eyes. CONCLUSION: OKULIX ray-tracing IOL power measurements provides reliable and satisfactory postoperative results, which are comparable to other 3rd generation formulas of SRK-T and Hoffer Q. Elsevier 2017-10-27 /pmc/articles/PMC5859630/ /pubmed/29564411 http://dx.doi.org/10.1016/j.joco.2017.06.008 Text en Copyright © 2018, Iranian Society of Ophthalmology. Production and hosting by Elsevier B.V. http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Article
Ghoreyshi, Mohammad
Khalilian, Ahmadreza
Peyman, Mohammadreza
Mohammadinia, Mohaddeseh
Peyman, Alireza
Comparison of OKULIX ray-tracing software with SRK-T and Hoffer-Q formula in intraocular lens power calculation
title Comparison of OKULIX ray-tracing software with SRK-T and Hoffer-Q formula in intraocular lens power calculation
title_full Comparison of OKULIX ray-tracing software with SRK-T and Hoffer-Q formula in intraocular lens power calculation
title_fullStr Comparison of OKULIX ray-tracing software with SRK-T and Hoffer-Q formula in intraocular lens power calculation
title_full_unstemmed Comparison of OKULIX ray-tracing software with SRK-T and Hoffer-Q formula in intraocular lens power calculation
title_short Comparison of OKULIX ray-tracing software with SRK-T and Hoffer-Q formula in intraocular lens power calculation
title_sort comparison of okulix ray-tracing software with srk-t and hoffer-q formula in intraocular lens power calculation
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5859630/
https://www.ncbi.nlm.nih.gov/pubmed/29564411
http://dx.doi.org/10.1016/j.joco.2017.06.008
work_keys_str_mv AT ghoreyshimohammad comparisonofokulixraytracingsoftwarewithsrktandhofferqformulainintraocularlenspowercalculation
AT khalilianahmadreza comparisonofokulixraytracingsoftwarewithsrktandhofferqformulainintraocularlenspowercalculation
AT peymanmohammadreza comparisonofokulixraytracingsoftwarewithsrktandhofferqformulainintraocularlenspowercalculation
AT mohammadiniamohaddeseh comparisonofokulixraytracingsoftwarewithsrktandhofferqformulainintraocularlenspowercalculation
AT peymanalireza comparisonofokulixraytracingsoftwarewithsrktandhofferqformulainintraocularlenspowercalculation