Cargando…
Accuracy of a Self-monitoring Test for Identification and Monitoring of Age-related Macular Degeneration: A Diagnostic Case-control Study
OBJECTIVE: To evaluate diagnostic accuracy of a new self-monitoring device using a Vernier hyperacuity alignment task. METHOD: A total of 11 wet Age-Related Macular Degeneration (AMD) patients and 9 controls contributing 37 eyes were consecutively enrolled into this prospective diagnostic case-contr...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Bentham Open
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5861526/ https://www.ncbi.nlm.nih.gov/pubmed/29619125 http://dx.doi.org/10.2174/1874364101812010019 |
_version_ | 1783308112735764480 |
---|---|
author | Schmid, Martin K. Faes, Livia Bachmann, Lucas M. Thiel, Michael A. |
author_facet | Schmid, Martin K. Faes, Livia Bachmann, Lucas M. Thiel, Michael A. |
author_sort | Schmid, Martin K. |
collection | PubMed |
description | OBJECTIVE: To evaluate diagnostic accuracy of a new self-monitoring device using a Vernier hyperacuity alignment task. METHOD: A total of 11 wet Age-Related Macular Degeneration (AMD) patients and 9 controls contributing 37 eyes were consecutively enrolled into this prospective diagnostic case-control study at the retina centre of the Cantonal Hospital Lucerne, Switzerland. Vernier acuity testing (index test) and Optical Coherence Tomography (OCT, reference test) were performed in all participants. OCT scans were evaluated and graded by a retinal specialist masked to diagnosis and index test results. Candidate parameters of the index test to be used as the diagnostic statistic were identified using a bootstrap procedure. Ten parameters remaining were further assessed in univariate analyses. The overall Standard Deviation (SD) of absolute distances across all four axes of the Vernier acuity test provided the highest area under the Receiver Operating Characteristics (ROC) curve and was therefore selected. RESULTS: Mean age of patients with wet AMD was 81.2 years (SD 4.99), mean numbers of letters were 67.4 (SD 14.1). The proportion of women was similar in both groups (controls: 88%, wet AMD: 72%). The area under the ROC curve was 0.87 (95% confidence interval CI: 0.75- 0.99) indicating excellent discrimination. Best accuracy was reached at a cut-off value of 0.64 with a sensitivity of 75% and a specificity of 94%. CONCLUSION: This diagnostic case-control study of a new screening device for AMD shows acceptable diagnostic accuracy. The promising preliminary data of this study call for further upstream evaluations in reasonably sized clinical studies. |
format | Online Article Text |
id | pubmed-5861526 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Bentham Open |
record_format | MEDLINE/PubMed |
spelling | pubmed-58615262018-04-04 Accuracy of a Self-monitoring Test for Identification and Monitoring of Age-related Macular Degeneration: A Diagnostic Case-control Study Schmid, Martin K. Faes, Livia Bachmann, Lucas M. Thiel, Michael A. Open Ophthalmol J Ophthalmology OBJECTIVE: To evaluate diagnostic accuracy of a new self-monitoring device using a Vernier hyperacuity alignment task. METHOD: A total of 11 wet Age-Related Macular Degeneration (AMD) patients and 9 controls contributing 37 eyes were consecutively enrolled into this prospective diagnostic case-control study at the retina centre of the Cantonal Hospital Lucerne, Switzerland. Vernier acuity testing (index test) and Optical Coherence Tomography (OCT, reference test) were performed in all participants. OCT scans were evaluated and graded by a retinal specialist masked to diagnosis and index test results. Candidate parameters of the index test to be used as the diagnostic statistic were identified using a bootstrap procedure. Ten parameters remaining were further assessed in univariate analyses. The overall Standard Deviation (SD) of absolute distances across all four axes of the Vernier acuity test provided the highest area under the Receiver Operating Characteristics (ROC) curve and was therefore selected. RESULTS: Mean age of patients with wet AMD was 81.2 years (SD 4.99), mean numbers of letters were 67.4 (SD 14.1). The proportion of women was similar in both groups (controls: 88%, wet AMD: 72%). The area under the ROC curve was 0.87 (95% confidence interval CI: 0.75- 0.99) indicating excellent discrimination. Best accuracy was reached at a cut-off value of 0.64 with a sensitivity of 75% and a specificity of 94%. CONCLUSION: This diagnostic case-control study of a new screening device for AMD shows acceptable diagnostic accuracy. The promising preliminary data of this study call for further upstream evaluations in reasonably sized clinical studies. Bentham Open 2018-03-13 /pmc/articles/PMC5861526/ /pubmed/29619125 http://dx.doi.org/10.2174/1874364101812010019 Text en © 2018 Schmid et al. https://creativecommons.org/licenses/by/4.0/legalcode This is an open access article distributed under the terms of the Creative Commons Attribution 4.0 International Public License (CC-BY 4.0), a copy of which is available at: (https://creativecommons.org/licenses/by/4.0/legalcode). This license permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Ophthalmology Schmid, Martin K. Faes, Livia Bachmann, Lucas M. Thiel, Michael A. Accuracy of a Self-monitoring Test for Identification and Monitoring of Age-related Macular Degeneration: A Diagnostic Case-control Study |
title | Accuracy of a Self-monitoring Test for Identification and Monitoring of Age-related Macular Degeneration: A Diagnostic Case-control Study |
title_full | Accuracy of a Self-monitoring Test for Identification and Monitoring of Age-related Macular Degeneration: A Diagnostic Case-control Study |
title_fullStr | Accuracy of a Self-monitoring Test for Identification and Monitoring of Age-related Macular Degeneration: A Diagnostic Case-control Study |
title_full_unstemmed | Accuracy of a Self-monitoring Test for Identification and Monitoring of Age-related Macular Degeneration: A Diagnostic Case-control Study |
title_short | Accuracy of a Self-monitoring Test for Identification and Monitoring of Age-related Macular Degeneration: A Diagnostic Case-control Study |
title_sort | accuracy of a self-monitoring test for identification and monitoring of age-related macular degeneration: a diagnostic case-control study |
topic | Ophthalmology |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5861526/ https://www.ncbi.nlm.nih.gov/pubmed/29619125 http://dx.doi.org/10.2174/1874364101812010019 |
work_keys_str_mv | AT schmidmartink accuracyofaselfmonitoringtestforidentificationandmonitoringofagerelatedmaculardegenerationadiagnosticcasecontrolstudy AT faeslivia accuracyofaselfmonitoringtestforidentificationandmonitoringofagerelatedmaculardegenerationadiagnosticcasecontrolstudy AT bachmannlucasm accuracyofaselfmonitoringtestforidentificationandmonitoringofagerelatedmaculardegenerationadiagnosticcasecontrolstudy AT thielmichaela accuracyofaselfmonitoringtestforidentificationandmonitoringofagerelatedmaculardegenerationadiagnosticcasecontrolstudy |